Step by Step Instructions for GRAFIK Eye Dimming Panel
17
Assign Primary Zones
STOP!
Before proceeding, you must have one or more of the
following:
■
Preassigned set-up
■
Knowledge of how the system is to operate.
■
Plans and specifications from owner’s
representative on how the system is to be set-up.
■
Owner or owner’s representative present.
■
What should each scene be used for?
Examples include - Breakfast, Lunch, Meeting, Accenting, etc...
■
How long should it take for the lights to fade from
scene to scene and to off?
Examples include - 1 second fade to “Meeting” scene, 10 minute
fade to “Lunch” scene so customers do not notice, 20 second
fade to “Off” scene to leave room before the lights go out, etc.
■
Do I have a 2Link
™
option?
If so . . . see Link Hierarchy options in the Reference Section.
S
ELECT
V
ALUE
V
IEW
V
ALUE
S
ELECT
V
ALUE
D
ISPLAYED
Load Type
(See Instructions)
Circuit Level
5
4
3
Zone Assignment w/
Circuit Schedule
Zone Assignment w/
Zone Capture
TM
Link A
Link B
S
ELECT
C
IRCUIT
2
1
Circuit
Common
24V
MUX
MUX
Drain
Sense
1 2 3 4
D
5
VALUE
A B
Comm
Drain
MUX
MUX
C
D
Link
Link
STEP 14:
Assign Primary Zones
A. Press and hold buttons 1 and 5 until the
SELECT VALUE
LED
flashes once per second.
B. Press button 5 repeatedly until the
Zone Assignment w/Circuit
Schedule
LED lights.
C. Select the primary zone assignment.
GRX 4000 Series:
Press button 3 or 4 to select both Control Unit
and zone assignment.
Example - If the control desired is addressed to ‘A2’ and the zone
desired is the 3rd from the left, use buttons 3 and 4 to get ‘A23’ as
a value for the appropriate circuit.
6000 Series or DMX512:
Press button 3 or 4 to select zone
assignment (1—512).
D. Use buttons 1 and 2 to change to the next circuit and then repeat
Step C. Do this for all affected circuits. Record each circuit’s control
and zone on a Circuit Directory.
E. Press and hold buttons 1 and 5 until the
VIEW VALUE
LED lights.
Notes:
■
The Circuit Selector’s display will go out automatically 20 minutes
after the last button press.
■
More than one circuit can be assigned to the same zone.
■
Zone Capture
™
is an alternate method for assigning zones. It is
described in the Circuit Selector Functions Reference Sheet.
■
2Link only- The Link A and Link B LEDs located next to the
Value
window indicate which Link is being assigned as per the Hierarchy.
To set the Hierarchy, see the reference sheet on 2Link options in
this guide.
S
ELECT
V
ALUE
V
IEW
V
ALUE
S
ELECT
V
ALUE
D
ISPLAYED
Load Type (See Instructions)
Circuit Level
5
4
3
Zone Assignment w/ Circuit Schedule
Zone Assignment w/ Zone Capture
TM
Link A
Link B
S
ELECT
C
IRCUIT
2
1
Circuit
Common
24V
MUX
MUX
Drain
Sense
1 2 3 4
D
5
VALUE
A B
Comm
Drain
MUX
MUX
C
D
Link
Link
A,E
B
C
D
For More Information . . .
16 and 24 zone GRX Control Units ....................26
?