2    Installation Guide for CGP2730 Dimming and Switching Subplate

Panel Model Number Guide

CGP2730 (120 V

~

 only)

Breakdown:

HWR - P N L S - 8 S - 1 2 0 F T - C G P 2 7 3 0

Feed 

Voltage

Feed 
Type

Subplate 
  Type

Prefix

Custom Function

2730

 = Subplate designed for retrofitting up

# of Module 
  locations

Prefix

HWR

 = Dimming & Switching Panel Subplate

 

Module locations and Types

 

       

The following module types may be installed in this subplate. 
Max 8 modules.  

Feed Type/Input Ratings

FT

V

0

2

1

 

h

g

u

o

h

t

-

d

e

e

F

  

=

 

~

Custom 
Function

to 8 modules into a LiteTouch

TM

.

MODULE 

LOCATION 

#1

MODULE 

LOCATION 

#3

MODULE 

LOCATION 

#5

MODULE 

LOCATION 

#7

MODULE 

LOCATION 

#2

MODULE 

LOCATION 

#4

MODULE 

LOCATION 

#6

MODULE 

LOCATION 

#8

The following Modules can be placed in locations 5 through 8

The following Modules can be placed in locations 1 through 4

Four-Output Dimming (4U) & (4A) 
cannot be placed in locations 5 
through 8

4U

4A

4A

Four-Output Dimming (4A) cannot be 
placed in locations 1 through 4

Output (Load) Ratings/Module Type Rating

4R 

64 A total per module (4 circuits/module), 16 A per circuit

4U

16 A total per module (1 circuit/module), 16 A per output, 
4 outputs per module

4J 

16 A total per module (1 circuit/module), 6 A per output, 
4 outputs per module

4M

 

16 A total per module (1 circuit/module), 5 A per output 
(1/4 HP motor, 1 per output), 4 outputs per module 

4FSQ  8 A total per module (1 circuit/module), 2 A per output 

(single ceiling fan), 4 outputs per module

Four-Circuit Switching Relay (4R) 

Four-Output Adaptive Dimming (4J)

Four-Output Motor (4M)
Four-Output Quiet Fan Speed (4FSQ)

Four-Output Dimming (4U)

Four-Circuit Switching Relay (4R) 

Four-Output Adaptive Dimming (4J)

Four-Output Motor (4M)
Four-Output Quiet Fan Speed (4FSQ)

WARNING!

 Shock hazard. 

 

             May result in serious injury or death. 
             Turn off all power feeding Existing 
LiteTouch panel before installing HWR 
retrofit devices. More than one disconnect 
may be necessary to de-energize panel. 
Use lockout/tagout on all disconnected 
power feeds.

Summary of Contents for CGP2730

Page 1: ...s ce lieu 4A CAUTION PRECAUCI N ATTENTION 4U Do not place HW RPM 4U 120 or HW RPM 4A 120 modules in this location No coloque HW RPM 4U 120 o HW RPM 4A 120 m dulos en esta ubicaci n Ne placez pas HW RP...

Page 2: ...gh 8 4U 4A 4A Four Output Dimming 4A cannot be placed in locations 1 through 4 Output Load Ratings Module Type Rating 4R 64 A total per module 4 circuits module 16 A per circuit 4U 16 A total per modu...

Page 3: ...UL compliance of the enclosure Existing Labels Remove all existing labels except for the UL Label Panel can be flush mounted or surface mounted and still be compatible with Lutron s front cover The Lu...

Page 4: ...120 HW RPM 4J 120 HW RPM 4FSQ 120 SH3 H4 SH5 N R1 L1 R2 L2 R3 N Quiet Fan Speed Control Module 120 V 50 60 Hz HW RPM 4M 120 L3 R4 L4 H H Installation Label Place the included label in the panel as sho...

Page 5: ...g a 29 size drill bit Clean inside of enclosure and reinstall subplate and secure with provided screws STEP ONE Place subplate into left side of the enclosure STEP TWO Slide subplate right the four gr...

Page 6: ...mm 2 mm or 2 3 8 in 10 mm 10 mm 10 mm 3 8 in 3 8 in 20 in lb 20 in lb 3 2 N m 2 8 N m 4 N m 25 in lb 35 in lb 6 4 AWG 0 AWG 1 4 1 8 AWG or 2 14 10 AWG 2 5 4 2 mm 6 1 0 1 2 mm 6 2 5 4 2 mm 2 mm or 2 3...

Page 7: ...2 14 10 AWG 2 5 4 2 mm 6 1 0 1 2 mm 6 2 5 4 2 mm 2 mm or 2 3 8 in 10 mm 10 mm 10 mm 3 8 in 3 8 in 20 in lb 20 in lb 3 2 N m 2 8 N m 4 N m 25 in lb 35 in lb 18 10 AWG 0 75 6 0 mm2 8 mm 5 16 in 0 6 0 8...

Page 8: ...g Module 4J 4 Output Fan Speed Control Module 4FSQ Use the following information to wire the newly installed modules Terminal Blocks N DH H DH DH DH Terminal blocks for 4U 4J and 4FSQ modules come pre...

Page 9: ...les and should be installed in place of the default terminal blocks as needed 4 RED WIRES BLACK WIRES WHITE WIRE N SH H SH H SH H SH H 4 3 3 2 2 1 1 4 4 3 2 3 2 2 3 4 4 3 2 1 Notice Make sure that no...

Page 10: ...ed in place of the default terminal blocks as needed N L H R L R L R L R Notice Make sure that no wires are pinched when installing the modules Pull check all wires to ensure a good connection and tha...

Page 11: ...ch load circuit Feed Wiring Mains Voltage Wiring Preferred feed wiring entry for subplate is between Load terminal blocks and Neutral Busses Run wiring so that line mains voltage wiring will be at lea...

Page 12: ...d Hot DH and or Switched Hot SH terminal blocks are grouped by a module 4 output circuits each in numbered order in the top right of the subplate The numbers represent the sequential circuit in the pa...

Page 13: ...load wiring to the appropriate load terminal set for each circuit and Neutral to the Neutral bus corresponding to the terminal block numbers in the vertical terminal blocks located in the center of t...

Page 14: ...on Termination at the processor end of the chain is included on HomeWorksR 8 Series processor boards so an LT 1A is not required On HomeWorksR QS processors link termination is also required at the pr...

Page 15: ...load bypassing the module WARNING Shock hazard May result in serious injury or death if panel is not wired correctly Verify the panel is fed from the correct voltage NOTE Do NOT remove bypass jumpers...

Page 16: ...are connected to the board the power plug for the Module Interface is plugged in and wired to the enclosure terminal blocks and that the circuit breaker is turned ON D Turn circuit breaker feeding mod...

Page 17: ...p y b e h t e r o t s d n a e v o m e R possible future use C Turn circuit breakers ON Notice Bypass jumper Module with 4 outputs shown Remove Bypass Jumpers Make sure installation is complete and po...

Page 18: ...nnecter plusieurs interrupteurs pour d charger l quipement avant l entretien WARNING AVERTISSEMENT Riesgo choque el ctrico Puede resultar enlesiones graves o la muerte Puede necesitarse m s de un conm...

Page 19: ...Notes Installation Guide for CGP2730 Dimming and Switching Subplate 19...

Page 20: ...lutron com http forums lutron com Warranty For Warranty information please see the Warranty enclosed with the product or visit www lutron com TechnicalDocumentLibrary HomeWorks_Warranty pdf www lutro...

Reviews: