43
SERVICES
Note: Always disconnect the electrical
connector between the towing vehicle
and the caravan before connecting an LV
(low voltage) supply to the caravan and
before charging the caravan battery by
any other means.
2. Ensure that your caravan mains isolating
switch (RCD) is in the off position. The
MCB's are the breakers for the individual
circuits.
3. Remove any cover from the electricity
inlet provided on the caravan, and
insert the connector of the supply
flexible cable.
4. Remove any cover from the socket
outlet provided at the site supply
point, and connect the plug (at the
other end of the supply flexible cable) to
this. Switch on the main switch at
the site supply point.
IN CASE OF DIFFICULTY CONSULT AN
APPROVED ELECTRICAL
INSTALLATION CONTRACTOR (WHO MAY
BE THE LOCAL ELECTRICITY COMPANY).
IT IS DANGEROUS TO ATTEMPT
MODIFICATIONS AND ADDITIONS
YOURSELF, LAMPHOLDER PLUGS
(BAYONET-CAP ADAPTORS) SHOULD
NOT IN ANY CIRCUMSTANCES BE USED.
On Leaving the Caravan Site
5. Reverse the procedure described in
Paragraphs 3 and 4 above.
IT IS IMPORTANT THAT THE MAIN
SWITCH AT THE SITE SUPPLY POINT
SHOULD BE SWITCHED OFF, THE
SUPPLY FLEXIBLE CABLE
DISCONNECTED, AND ANY COVER
REPLACED ON THE SOCKET OUTLET AT
THE SITE SUPPLY POINT. IT IS
DANGEROUS TO LEAVE THE SUPPLY
SOCKET OR SUPPLY FLEXIBLE CABLE
LIVE.
Periodically
6. Preferably not less than once a year,
the caravan electrical installation
should be inspected and tested and a
report on its condition obtained as
prescribed in the Regulations for
Electrical Installations published by
the Institute of Electrical Engineers.
Never allow modification of electrical
systems or appliances except by qualified
persons.
Outlet sockets located within the tourer
should only be used with a dedicated
appliance and not an independent unit.
No appliance shall be used outside when
connected to an internal socket.
YOUR CARAVAN IS NOW SUPPLIED
WITH 25 METRES OF MAINS CABLE TO
COMPLY WITH BS EN1645.
FLEXIBLE WIRING
LIVE
BROWN
NEUTRAL
BLUE
EARTH
GREEN & YELLOW
FIXED WIRING
LIVE
BROWN
NEUTRAL
BLUE
EARTH
GREEN & YELLOW
Summary of Contents for Caravans
Page 15: ...15 PREPARING FOR THE ROAD Fig 5 Fig 6 Fig 9 Fig 8 Fig 7 Fig 10...
Page 26: ...ON THE ROAD 26...
Page 31: ...31 SERVICES SERVICES Water 32 Gas 38 Electricity 42...
Page 44: ...SERVICES 44...
Page 45: ...45 ELECTRICS ELECTRICS Power Control System 46 Battery 58 Use of Generators 59...
Page 49: ...49 ELECTRICS 2 5 Control Panel Component Layout EC350 Digital Control Panel LED display...
Page 60: ...ELECTRICS 60...
Page 84: ...84 THETFORD TOILETS...
Page 85: ...85 THETFORD TOILETS...
Page 96: ...96 7 Fit the safety boards into position BUNK BEDS...
Page 106: ...GENERAL DATA 106...
Page 107: ...107 GENERAL DATA...
Page 108: ...GENERAL DATA 108...
Page 109: ...109 GENERAL DATA...
Page 110: ...GENERAL DATA 110 EC175 Power Supply Unit Consumer Circuits Roof...
Page 111: ...111 GENERAL DATA...
Page 112: ...GENERAL DATA 112...