Lumos AIRmini Operation Manual Download Page 20

 

Stand 2012-10 

 

Seite /page 20 / 28 

 

3.

 

Anschluss-Sets / Connection Sets 

Set 000.295  

 
Anschluss-Set für  
32 mm Abwasserschlauch /  
 
Connection set for edgers with  
32 mm sewage tube 

 

 

Set 001.300 

 
Anschluss-Set für den Direktanschluss  
an NIDEK Maschinen  
(9000/9090/ME1000) /  
 
Connection set for direct connection  
to NIDEK edgers  (9000/9090/ME1000)  
 

Set 000.802 

 
Anschluss-Set für  
50/60/63 mm Abwasserschlauch / 
  
Connection set for edgers which have  
50/60/63 mm sewage tubes  
 

Set 001.006 

 
Anschluss-Set für  
100 mm Abwasserschlauch /  
 
Connection set for edgers which have a  
100 mm sewage tube  
 

Summary of Contents for AIRmini

Page 1: ...Bedienungsanleitung Operation Manual AIRmini Stand 2012 10...

Page 2: ...Stand 2012 10 Seite page 2 28 Inhalt Content 1 Bedienungsanleitung 2 Operation Manual 3 Anschluss Sets Connection sets 4 Betriebsmittel Supplies...

Page 3: ...ktrische und magnetische Gefahren Stellen Sie sicher dass das Ger t mit einem Stromanschluss verbunden ist der dieselbe Spannung und Frequenz besitzt wie sie auf dem Maschinenschild angegeben ist und...

Page 4: ...genoptikerwerkstatt zu reduzieren saugt AIRmini die verschmutzte Luft direkt aus der Bearbeitungsmaschine ab und reinigt sie dann in einem hochreaktiven Breitbandfilter von den Ger chen Dies geschieht...

Page 5: ...sind die folgenden Punkte zu beachten Das Ger t muss auf festem Untergrund kippsicher aufgestellt werden Die gereinigte Luft muss frei nach links und rechts entweichen k nnen Betreiben Sie das Ger t...

Page 6: ...cken Sie am besten mit den Daumen von oben gegen die Gummidichtung 3 Um das Einsetzen des Filters zu erleichtern empfiehlt es sich etwas Seife Gleitmittel Vaseline oder l Fett auf die u ere Dichtfl ch...

Page 7: ...an den seitlichen Luftausl ssen einen Luftstrom sp ren Pr fen Sie ob Sie mit dem Regler f r die Ansaugleistung die Ventilatordrehzahl und damit die Leistung verstellen k nnen Durch Drehen des Reglers...

Page 8: ...n eingesetzten HT System Soll die Absaugung ber eine fest installierte Abwasserleitung erfolgen so ist ein entsprechender Abzweig mit einer Reduktion auf die Gr e DN50 zu installieren In diesen Abzwei...

Page 9: ...ng deutlich nachl sst oder der Filter vollst ndig mit Partikeln durchsetzt ist Die Lebensdauer kann je nach Einsatz variieren Regelm iger Wechsel der Filterpads verl ngert die Lebensdauer des Breitban...

Page 10: ...Stand 2012 10 Seite page 10 28 Gew hrleistungsbedingungen Es gelten unsere Allgemeinen Verkaufsbedingungen f r Inlandsgesch fte in der aktuellen Version Operation Manual AIRmini...

Page 11: ...Stand 2012 10 Seite page 11 28 State 2011 10...

Page 12: ...ic and magnetic dangers Make sure that the device is connected with a bus bar that provides the same voltage and frequency as stated on the type plate and that it is grounded according to the local re...

Page 13: ...e the odours emissions and their impacts AIRmini extracts the gas directly out of the edger and purifies the air with a high reactive broadband filter This is realized by absorption which means that t...

Page 14: ...ack Set up and required space Please always follow these instructions The device must be placed on a solid and stable subsurface The air in and outlet must be kept entirely free so that the purified a...

Page 15: ...ur thumbs against the rubber seal 3 To simplify the insertion of the filter soap slip agent vaseline or oil grease should be laid on the outer seal 4 Check if the filter is attached securely 5 6 Put t...

Page 16: ...u can feel a stream of air out of the side air outlets Check if you can change the ventilator speed and thus the power with the controller that regulates the suction power By turning the control of th...

Page 17: ...work with an already established installed drainage tube an appropriate junction with a reduction to size DN50 has to be installed In that junction the connecting piece 000 280 or another tube with th...

Page 18: ...rts to decrease or if the filter is completely interspersed with particles The filterpad s lifespan may vary depending on the frequency of use Exchanging the filterpads regularly will extend the lifes...

Page 19: ...Stand 2012 10 Seite page 19 28 Warranty conditions For all of our sales our general sales terms Allgemeine Verkaufsbedingungen f r Inlandsgesch fte are valid as per update version...

Page 20: ...Anschluss Set f r den Direktanschluss an NIDEK Maschinen 9000 9090 ME1000 Connection set for direct connection to NIDEK edgers 9000 9090 ME1000 Set 000 802 Anschluss Set f r 50 60 63 mm Abwasserschla...

Page 21: ...afely by a grub screw The tube 1 is put on The inset for the WECO water box has no seal on the top of it so that the Y part can easily be removed in the case of cleaning The junction 3 can now be conn...

Page 22: ...ice 2 Den Schlauch vorsichtig in den Gummiring einsetzen ggf leicht drehen Put tube carefully into the seal ring if necessary screw slightly 3 Das andere Ende des Schlauches auf das Anschlussrohr der...

Page 23: ...er the drainage tube 50 mm 9 and push both parts in The junction 4 is then pushed alternatively into the DN75 drainage tube 8 or both fittings 5 6 are screwed together with the top of the water box as...

Page 24: ...set into the junction 4 The drainage tube 1 is pushed in screwingly The tube 2 is pushed up onto the connecting piece The junction 4 can directly be pushed into the existing DN100 connections 5 or int...

Page 25: ...ang wie n tig sein Installation according to small height at least 8cm are necessary Put component 7 into the water box the opening must be turned down Fill the water box with water until it reaches a...

Page 26: ...Stand 2012 10 Seite page 26 28 4 Betriebsmittel Supplies 000 521 Filterpatrone Filter cartridge 000 865 Filterpads 10 St 001 143 Filterpads 75 St 000 205 Geruchspatronen Air fresheners...

Page 27: ...pads warden aus einem hocheffizienten Filtermaterial hergestellt das auch bei lungeng ngigen St uben 10 nm sehr hohe Abscheidungsraten erreicht Je nach Glasart sollten sie alle 100 bis 250 Gl ser gewe...

Page 28: ...Stand 2012 10 Seite page 28 28 Hersteller Manufacturer LUMOS GmbH...

Reviews: