TECHNICAL INSTRUCTION, USER MANUAL AND 

INSTALLATION MANUAL

 

 

 

ul. Główna 51 B, Krosno; 62

 

Heating boiler with automatic fuel delivery 

BIO-MAX PLUS 

Series of types 70 – 300 kW 

TECHNICAL INSTRUCTION, USER MANUAL AND 

INSTALLATION MANUAL 

 

LUMO Technika Grzewcza Sp. z o.o. 

ul. Główna 51 B, Krosno; 62-050 Mosina 

telephone/t48 61 8136 525 

 

 

TECHNICAL INSTRUCTION, USER MANUAL AND 

Summary of Contents for BIO-MAX PLUS

Page 1: ...N MANUAL ul G wna 51 B Krosno 62 Heating boiler with automatic fuel delivery BIO MAX PLUS Series of types 70 300 kW TECHNICAL INSTRUCTION USER MANUAL AND INSTALLATION MANUAL LUMO Technika Grzewcza Sp...

Page 2: ...quality 14 4 7 Connection to the electrical system 14 4 8 Connection to the domestic hot water exchanger option 17 4 9 Connection of the boiler to a chimney stack system 18 5 OPERATION 19 5 1 Prepara...

Page 3: ...constant development and improvement of our products we would ask you to send us all and any comments concerning the functioning of our appliances and the level of service provided by our partners We...

Page 4: ...two weeks of the date of initial start up shall void the guarantee for your newly purchased appliance thus resulting in the user being required to cover the entirety of costs of all and any repair wor...

Page 5: ...hen there is a risk of water freezing in the system Water should also be drained in the event of a leak which may result in flooding ATTENTION It is forbidden to tamper with safety devices Only origin...

Page 6: ...e of their nature and scope may be carried out solely following disconnection of the power supply Further repairs may be carried out EXCLUSIVELY by the Authorised Service Centre or duly authorised per...

Page 7: ...t while in the upper part is a large and easily accessible washout hole which facilitates cleaning of the heat exchanger and the smoke tubes A tray for ash is located in the bottom part of the boiler...

Page 8: ...8 Figure No 2 Component elements of the boiler Figure No 2 Component elements of the boiler...

Page 9: ...9...

Page 10: ...10 3 2 Technical parameters Figure No 3 Boiler installation dimensions...

Page 11: ...factured in accordance with PN EN ISO 17225 2 2014 07 Voltage V Hz 230 50 Electrical terminal A 6 Power consumption in standby W 3 Power consumption under nominal operating conditions W 234 278 630 66...

Page 12: ...ther the phase conductor L is correctly located and whether the outlet has a ground terminal that is in good working order 4 2 Location of the boiler The boiler should be located in a separate room pu...

Page 13: ...775 4 3 Installation of the burner Installation of the burner consists solely in attaching it by means of screws to the boiler door The pertinent detailed technical information screw thread diameters...

Page 14: ...n Table No 1 These stub connectors and their corresponding joints are used to connect the boiler to the central heating system in the appropriate manner so as not to mix up supply with return for exam...

Page 15: ...required 4 6 Guidelines concerning water quality The quality of water used to fill the boiler and the system is of critical importance for their longevity and trouble free operation Inappropriate boil...

Page 16: ...16 Figure No 7 Wiring diagram ecoMAX860P Standard and ecoMAX860P Touch...

Page 17: ...eather based temperature sensor type CT6 P RS return water temperature sensor type CT4 FS feeding mechanism temperature sensor type CT4 OS optical flame brightness sensor BT boiler temperature sensor...

Page 18: ...RM2 room thermostat mixer 2 RM3 room thermostat mixer 3 L N PE power supply 230 V GR grounding strip PM2 PM3 pump mixer 2 3 SM2 SM3 servo motor mixer 2 3 CPU control A executory module of the ecoMAX8...

Page 19: ...ned by the duly authorised system designer The following figure presents an exemplary diagram of a system comprising a LUMO WCW hot domestic water exchanger and a Bio max Plus boiler Figure No 10 Exem...

Page 20: ...cts being released by the boiler into the boiler room and the concentration of CO in the combustion chamber While Bio max Plus boilers operate in their lower power range the temperature of flue gases...

Page 21: ...e boiler it is necessary to perform a fresh inspection of the appliance and its ancillary devices and in particular to carry out an internal inspection of the boiler water filling inspection to carry...

Page 22: ...manuals delivered together with these two devices During initial start up there may occur the phenomenon of boiler sweating In this event it will be necessary to intensify the combustion process in o...

Page 23: ...its ancillary devices at least once a year preferably before the start of the heating season The entirety of repairs inspections adjustments and maintenance may be performed solely by the Authorised S...

Page 24: ...ce a year every 12 months Inspection of the functioning of regulating and safety devices including the safety valve and the safety temperature limiter STB Inspection of the ventilation system Inspecti...

Page 25: ...urner in order to gain access to the combustion chamber and the smoke tubes Remove the flue gas turbulators coils from the smoke tubes Use a round steel brush seated on a cleaning rod to carefully cle...

Page 26: ...y of activities described under the present point are to be performed solely by the Authorised Service Centre 6 4 1 General guidelines During each inspection and maintenance operation performed on the...

Page 27: ...manufacturer must be followed at all times during such checks All and any failures caused by the incorrect functioning of the burner or brought about intentionally are displayed on the control panel...

Page 28: ...s and leads The controller has got damp Damaged display Check the electrical connection of the boiler Check the correctness of installation of plugs and whether the controller has been properly connec...

Page 29: ...29...