GB
Suspended light fi tting for general lighting, for both in- and out-
door use, made of die-cast aluminium, a diffuser in polyethylene
and a feeding wire in neoprene. Possibility of cascaded installa-
tions (fi g. 5-6-7) since you can electrically connect several fi ttings
to the same power connection. Possibility of vertical and horizon-
tal adjustments by means of ropes and other accessories of simple
use. Many installation options are possible for one or more fi ttings.
Lamping: E27 max 30W compact fl uorescent - max 60W halogen.
Degree of protection IP65.
NOTICE - INSTALLATION TIPS
The symbol
recommends the minimum distance to be
kept from the lighted object.
In case of halogen lamp installing or replacement please use a self
shielded tungsten halogen lamp only
.
Warning
: read and carefully follow this instruction: we recom-
mend that a specialized technician carries out this job.
Warning
: always cut off the current prior to start any operations.
Warning
: for serial wiring it is mandatory to comply with the Eu-
ropean Norms that prescribe the use of the components (feed-
ing wires, cable glands, cable clamps etc.) that are included in this
package.
Warning
: when connecting this fi tting to the main network for
outdoor use, use appropriate components (feeding wire, cable-
clamps, junction-boxes, plugs, etc.) with a minimum degree of pro-
tection of IP44, or more. For model Perla Mono 35 M - code 851,
use a cable H05RN-F 2x075, Ø 5,5 - 6,5 mm bearing the HAR mark
of conformity
Warning
: maximum load for this power feeding system is 600W in
case of a cascaded installation down one only light point.
Warning
: use hooks and dowels suitable to the kind of ceiling or
wall, and to the total weight of the fi ttings to be installed:
Q.ty 1 Perla Mono 35 = 2,6kg. Consider wind motion in case of out-
door use.
Warning
: for model Perla Mono 35 M - cod. 851, the use of sets
code 820 (
fi g.2
) and code 821 (
fi g.3
) is recommended.
Warning
: in case of horizontally tensioned mount, as shown in
pict. 6
, we recommend the use of architectural steel cables (not
included in this package).
To clean the fi tting: never carry it out when the fi tting is still warm.
Only use neutral cleaning products.
INSTALLING OR REPLACING BULBS - MAINTENANCE
SINGLE MOUNT - Perla Mono 35 M (code 851)
(
Fig. 1
) •Remove the screws
(A)
from the tap
(B)
with the Allen key
included in box.
•Then remove the diffuser and carry out maintenance works (in-
stalling or replacing the bulb, cleaning etc.).
(
Fig. 8
) • Thread the feeding wire through the cable-lead
(O)
and
connect it to the terminal, then tighten it by use of the cable-clamp
inside the box
(P)
.
•Tighten the ring-nut of the cable-lead
(O)
fi rmly.
•After that put the diffuser at its place again and tighten the screws
(A)
.
Warning
: make sure that washers
(C)
are set correctly.
•For ceiling or wall mount use hooks for dowels suitable to the
weight of this light fi tting (2,6kg) and to the kind of ceiling or wall.
•Connect the feeding wire to the electric main network.
INSTALLING OR REPLACING BULBS - MAINTENANCE
SERIAL FEEDING / SINGLE MOUNT - Perla Mono 35 (cod. 850)
(
Fig. 1
) •Remove the screws
(A)
from the tap
(B)
with the Allen key
included in box.
•Then remove the diffuser and carry out maintenance works (in-
stalling or replacing the bulb, cleaning of the glass etc.).
•After that put the diffuser at its place again and tighten the screws
(A)
.
Warning
: make sure that washers
(C)
are set correctly.
INSTALLING - SUPPORTING ROPES
1
) Mount the hooks
(I)
(
fi g.3
) or some other supports suitable to
the kind of ceiling or wall, and to the total weight of the composi-
tion to be installed.
2
) Cut the ropes
(D)
to needed length (
fi g. 2
) (
notice
: wrap the cut
end with a tape), with slots as sketched, and close the two shells
(E)
screwing the bolt
(F)
and the nut
(G)
.
•Hook the carabiners
(H)
to the slots.
(
fi g. 4
) •Hook the carabiners
(H)
to the connection points
(I)
and
to the supports
(L)
.
•Connect the feeding wire to the electric main network.
INSTALLATION WITH SERIAL FEEDING
(
fi g. 4
) •Place and hook all the fi ttings prior to carry out electrical
connections, in order to correctly estimate the cable-lengths (al-
ways add 40 cm to the distance between fi ttings).
•Hook the carabiners
(H)
to the connection points
(C)
and to the
supports
(I)
.
We recommend to keep a 70 cm minimum distance between
fi ttings
.
If you fi nd the composition satisfactory, cut all the exceeding feed-
ing cables.
Warning
: do not exceed the maximum weight load: 50 kg.
•Unhook the fi ttings and lay them down (on ground or table) for
an easier electrical connection to each other.
3
) (
fi g.1
) Remove the screws
(A)
from cover
(B)
, by use of the Allen
key included in box, and shift the diffuser.
4
) (
fi g.8
) Release the bolt
(M)
by use of the box spanner/wrench
(Q)
included in box, and remove the cap
(N)
.
•Mount the cable-lead
(O)
included in box, together with all Its
components, as shown in picture.
•Thread the feeding wire through the cable-lead
(O)
and connect
it to the terminal, then tighten it by use of the cable-clamp inside
the box
(P)
. Tighten the ring-nut of the cable-lead
(O)
fi rmly.
5
) Proceed as per points
3
and
4
again to connect all the fi ttings
to each other.
(
fi g.1
) •Mount the sources, and tighten the screws
(A)
to set the
diffuser.
Warning
: make sure that washers
(C)
are set correctly.
6
) Once the fi ttings are connected together you need the help
from one or more people to hook the system to the supports
(I)
that you had previously mount to the walls or to the ceiling.
7
) Connect the feeding wire to the electric main network.
Carefully read the instructions before assembling the light
fi tting which is guaranteed safe and reliable when it has been
correctly installed and properly used. We recommend to con-
serve the instructions.
GUARANTEE
This light fi tting is guaranteed under the conditions in
force in the Country of sale. For claims under guarantee, the sales re-
ceipt must be shown.
REMARKS FOR A SAFE USE
The light fi tting that you have purchased has been designed and built
according to European security norms in force and is certifi ed by an
appointed Institute for Quality Marks.
The safe use of a light fi tting emboding high temperature
components requires, beyond the necessary attention, to carefully
follow these instructions:
Read carefully and conserve the instructions for the correct use of
the light fi tting.
We suggest to have the fi tting installed by a specialized technician.
Do not
use the light fi tting for improper applications, that haven’t been
foreseen in the project.
Do not
use bulbs of higher power than the one specifi ed in the
instructions and on the labels sticked on the light fi tting.
When cleaning or changing the bulb of the light fi tting, remember to
previously unplug the same or switch off the main.
Let the light fi tting and the bulb cool down before touching it with the
hands.
Moreover, we suggest to remember:
Never
clean the light fi tting when hot or under tension.
Never
use fl ammable products to clean the light fi tting.
The glass components - bulb included - can break and therefore are
dangerous
if uncarefully handled.
Light fi ttings should be installed
out of the reach of children
and in such
a position where they cannot be hit by anything.
Do not
install the light fi tting too close to fl ammable materials (curtains,
etc.), nor cover it, to prevent the normal cooling.
Do not
allow children to play with the fi tting.
In case of troubles, misworking or damage to the cable, contact your
Lumina dealer for checking and repairing.