background image

GB

Suspended light fi tting for general lighting, for both in- and out-
door use, made of die-cast aluminium, a diffuser in polyethylene 
and a feeding wire in neoprene. Possibility of cascaded installa-
tions (fi g. 5-6-7) since you can electrically connect several fi ttings 
to the same power connection. Possibility of vertical and horizon-
tal adjustments by means of ropes and other accessories of simple 
use. Many installation options are possible for one or more fi ttings.
Lamping: E27 max 30W compact fl uorescent - max 60W halogen.
Degree of protection IP65.

NOTICE - INSTALLATION TIPS

The symbol 

 recommends the minimum distance to be 

kept from the lighted object.
In case of halogen lamp installing or replacement please use a self 
shielded tungsten halogen lamp only 

.

Warning

: read and carefully follow this instruction: we recom-

mend that a specialized technician carries out this job.

Warning

: always cut off the current prior to start any operations.

Warning

: for serial wiring it is mandatory to comply with the Eu-

ropean Norms that prescribe the use of the components (feed-
ing wires, cable glands, cable clamps etc.) that are included in this 
package.

Warning

: when connecting this fi tting to the main network for 

outdoor use, use appropriate components (feeding wire, cable-
clamps, junction-boxes, plugs, etc.) with a minimum degree of pro-
tection of IP44, or more. For model Perla Mono 35 M - code 851, 
use a cable H05RN-F 2x075, Ø 5,5 - 6,5 mm bearing the HAR mark 
of conformity

Warning

: maximum load for this power feeding system is 600W in 

case of a cascaded installation  down one only light point.

Warning

: use hooks and dowels suitable to the kind of ceiling or 

wall, and to the total weight of the fi ttings to be installed:
Q.ty 1 Perla Mono 35 = 2,6kg. Consider wind motion in case of out-
door use.

Warning

: for model Perla Mono 35 M - cod. 851, the use of sets 

code 820 (

fi g.2

) and code 821 (

fi g.3

) is recommended.

Warning

: in case of horizontally tensioned mount, as shown in 

pict. 6

, we recommend the use of architectural steel cables (not 

included in this package).
To clean the fi tting: never carry it out when the fi tting is still warm. 
Only use neutral cleaning products.

INSTALLING OR REPLACING BULBS - MAINTENANCE

SINGLE MOUNT  - Perla Mono 35 M (code  851)

(

Fig. 1

) •Remove the screws 

(A)

 from the tap 

(B)

 with the Allen key 

included in box. 
•Then remove the diffuser and carry out maintenance works (in-
stalling or replacing the bulb, cleaning etc.). 
(

Fig. 8

) • Thread the feeding wire through the cable-lead 

(O)

 and 

connect it to the terminal, then tighten it by use of the cable-clamp 
inside the box  

(P)

.

•Tighten the ring-nut of the cable-lead 

(O)

 fi rmly.

•After that put the diffuser at its place again and tighten the screws 

(A)

.

Warning

: make sure that washers 

(C)

 are set correctly.

•For ceiling or wall mount use hooks for dowels suitable to the 
weight of this light fi tting (2,6kg) and to the kind of ceiling or wall. 
•Connect the feeding wire to the electric main network.

INSTALLING OR REPLACING BULBS - MAINTENANCE

SERIAL FEEDING / SINGLE MOUNT  - Perla Mono 35 (cod. 850)

(

Fig. 1

) •Remove the screws 

(A)

 from the tap 

(B)

 with the Allen key 

included in box. 
•Then remove the diffuser and carry out maintenance works (in-
stalling or replacing the bulb, cleaning of the glass etc.). 
•After that put the diffuser at its place again and tighten the screws 

(A)

.

Warning

: make sure that washers 

(C)

 are set correctly.

INSTALLING - SUPPORTING ROPES

1

) Mount the hooks 

(I)

 (

fi g.3

) or some other supports suitable to 

the kind of ceiling or wall, and to the total weight of the composi-
tion to be installed.  

2

) Cut the ropes 

(D) 

to needed length (

fi g. 2

) (

notice

: wrap the cut 

end with a tape), with slots as sketched, and close the two shells 

(E)

 

screwing the bolt 

(F)

 and the nut 

(G)

.

•Hook the carabiners 

(H)

 to the slots.

(

fi g. 4

) •Hook the carabiners 

(H)

 to the connection points 

(I)

 and 

to the supports 

(L)

.

•Connect the feeding wire to the electric main network. 

INSTALLATION WITH SERIAL FEEDING

(

fi g. 4

) •Place and hook all the fi ttings prior to carry out electrical 

connections, in order to correctly estimate the cable-lengths (al-
ways add 40 cm to the distance between fi ttings).   
•Hook the carabiners 

(H)

 to the connection points 

(C)

 and to the 

supports 

(I)

.

We recommend to keep a 70 cm minimum distance between 
fi ttings

.

If you fi nd the composition satisfactory, cut all the exceeding feed-
ing cables.

Warning

: do not exceed the maximum weight load: 50 kg.

•Unhook the fi ttings and lay them down (on ground or table)  for 
an easier electrical connection to each other.

3

) (

fi g.1

) Remove the screws 

(A)

 from cover 

(B)

, by use of the Allen 

key included in box, and shift the diffuser.

4

) (

fi g.8

) Release the bolt 

(M)

 by use of the box spanner/wrench 

(Q)

 included in box, and remove the cap 

(N)

.

•Mount the cable-lead 

(O)

 included in box, together with all Its 

components, as shown in picture.
•Thread the feeding wire through the cable-lead 

(O)

 and connect 

it to the terminal, then tighten it by use of the cable-clamp inside 
the box  

(P)

. Tighten the ring-nut of the cable-lead 

(O)

 fi rmly.

5

) Proceed as per points 

3

 and 

4

 again to connect all the fi ttings 

to each other.
(

fi g.1

) •Mount the sources, and tighten the screws 

(A)

 to set the 

diffuser.

Warning

: make sure that washers 

(C)

 are set correctly.

6

) Once the fi ttings are connected together you need the help 

from one or more people to hook the system to the supports 

(I) 

that you had previously mount to the walls or to the ceiling.

7

) Connect the feeding wire to the electric main network.

Carefully read the instructions before assembling the light 

fi tting which is guaranteed safe and reliable when it has been 

correctly installed and properly used. We recommend to con-

serve the instructions.

GUARANTEE 

This light fi tting is guaranteed under the conditions in 

force in the Country of sale.  For claims under guarantee, the sales re-
ceipt must be shown. 

REMARKS FOR A SAFE USE 

The light fi tting that you have purchased has been designed and built 
according to European security norms in force and is certifi ed by an 
appointed Institute for Quality Marks. 

The safe use of a light fi tting emboding high temperature 
components requires, beyond the necessary attention, to carefully 
follow these instructions:
Read carefully and conserve the instructions for the correct use of 
the light fi tting. 

We suggest to have the fi tting installed by a specialized technician.

Do not 

use the light fi tting for improper applications, that haven’t been 

foreseen in the project.

Do not 

use bulbs of higher power than the one specifi ed in the 

instructions and on the labels sticked on the light fi tting. 
When cleaning or changing the bulb of the light fi tting, remember to 
previously unplug the same or switch off the main. 
Let the light fi tting and the bulb cool down before touching it with the 
hands. 
Moreover, we suggest to remember:

Never

 clean the light fi tting when hot or under tension.

Never

 use fl ammable products to clean the light fi tting. 

The glass components - bulb included - can break and therefore are 

dangerous

 if uncarefully handled. 

Light fi ttings should be installed 

out of the reach of children

 and in such 

a position where they cannot be hit by anything.

Do not

 install the light fi tting too close to fl ammable materials (curtains, 

etc.), nor cover it, to prevent the normal cooling. 

Do not

 allow children to play with the fi tting.

In case of troubles, misworking or damage to the cable, contact your 
Lumina dealer for checking and repairing. 

Summary of Contents for PERLA GARDEN 35

Page 1: ...PERLA GARDEN 35 PERLA GARDEN 35 M design Ettore Cimini Walter Monici Istruzioni Hinweisungen Instructions Instrucci nes D E D F E H 10 cm G A B A C 2 1 Set Ropes cod 820...

Page 2: ...MIN 70 cm MIN 70 cm MIN 70 cm MIN 70 cm 5 6 I H H L I 3 4 Set Hooks cod 821...

Page 3: ...O M C C N Q P C 7 8 9 9a...

Page 4: ...distanza tra gli apparecchi Agganciare i moschettoni H ai punti di attacco C ed ai ai ganci I consigliata tra gli apparecchi una distanza minima di 70cm Se la disposizione soddisfacente tagliare il ca...

Page 5: ...zwischen den Leuchten 70cm Nach Beendigung der Installation bersch ssige Kabel abschneiden Achtung Die Leine ber max 50kg nicht spannen Leuchten vorsichtig abh ngen so ist relativ schnell die elektri...

Page 6: ...ween fittings Hook the carabiners H to the connection points C and to the supports I We recommend to keep a 70 cm minimum distance between fittings If you find the composition satisfactory cut all the...

Page 7: ...REMPLACEMENT DE L AMPOULE ENTRETIEN INSTALLATION INDIVIDUELLE Perla Garden 35 M code 861 Fig 1 Du c t oppos au c ble d alimentation enlevez les vis A du couvercle B au moyen de la cl Allen incluse En...

Page 8: ...filar el cable de alimentaci n el ctrica a trav s el pasecable O y conectarlo a la abrazadera cierrandola por la abrazadera incluida en la caja P Atornillar la tuerca de la abrazadera O con firmeza De...

Page 9: ...CHT MIT ALKOHOL REINIGEN GB ATTENTION PLASTIC COMPONENTS DO NOT CLEAN WITH ALCOHOL F ATTENTION PARTIES COMPOSANTES EN PLASTIQUE NE PAS NETTOYER AVEC L AL COHOL NL ATTENTIE PLASTIC ONDERDELEN NIET REIN...

Page 10: ...l organisation that serves your house or the store at which you purchased the product The store can also withdraw the product Wrong disposal may cause damages to people and the environment for the pos...

Page 11: ...PERLA MONO 35 PERLA MONO 35 M design Ettore Cimini Walter Monici Istruzioni Hinweisungen Instructions Instrucci nes D E D F E H 10 cm G A B C A 2 1 Set Ropes cod 820...

Page 12: ...MIN 70 cm MIN 70 cm MIN 70 cm 5 7 I H H L I 3 4 6 Set Hooks cod 821...

Page 13: ...O M N Q P C O M P C 8...

Page 14: ...le asole come mostrato e chiudere i gusci E avvitan do la vite F al dado G Agganciare i moschettoni H alle asole Fig 4 Agganciare i moschettoni H ai ganci I ed ai punti di attacco L Collegare il cavo...

Page 15: ...rabinerhaken H an die se einh ngen Abb 4 Karabinerhaken H an den Haken I und an den Befesti gungspunkt L einh ngen Das Leitungskabel mit der Elektroanlage verbinden MONTAGE MIT KETTENVERBINDUNG Abb 4...

Page 16: ...ice wrap the cut end with a tape with slots as sketched and close the two shells E screwing the bolt F and the nut G Hook the carabiners H to the slots fig 4 Hook the carabiners H to the connection po...

Page 17: ...in stall s N 1 Perla Mono 35 2 6kg Dans les espaces ext rieurs il faut tenir compte des mouvements dus au vent Attention pour le mod le Perla Mono 35 M cod 851 nous recom mandons l emploi des kits de...

Page 18: ...leo de tensores de acero no incluidos en el producto Emplear productos neutros para limpiar el cristal hacer esta opera ci n con la l mpara fria y no ponerlo bajo agua corriente INSTALAR O REEMPLAZAR...

Page 19: ...CHT MIT ALKOHOL REINIGEN GB ATTENTION PLASTIC COMPONENTS DO NOT CLEAN WITH ALCOHOL F ATTENTION PARTIES COMPOSANTES EN PLASTIQUE NE PAS NETTOYER AVEC L AL COHOL NL ATTENTIE PLASTIC ONDERDELEN NIET REIN...

Page 20: ...l organisation that serves your house or the store at which you purchased the product The store can also withdraw the product Wrong disposal may cause damages to people and the environment for the pos...