02100005 Rev 1
CCPF-500 CCPF-750 User Manual
Page 6 of 17
4.
CCPF-500 Interface
Connector Type 15 pin D-sub Female
Refer to Figure 2, CCPF-500 15-pin Interface Schematic
Table 1, CCPF Interface
Pin #
Pin Name
Functional Level
Description
1
Inhibit/Fault
Reset
(input)
Low = RUN, <0.3V
High = OFF, +5V to
+15V
This pin is the basic ON/OFF control pin for the power
supply. Grounding pin 1 enables power supply
operation if all faults are clear. Ap10 to 15V to
pin 1 prevents the inverter from operating. Optional
High Enable available, contact factory, see note 2.
NOTE: The power supply should be INHIBITED via Pin
1 before the capacitor is discharged into the load.
Noise from the discharge could cause improper
operation if the power supply is not INHIBITED.
2, 3, 6,
10, 11,
12
No connect
Optional, may be used for customer specified
functionality, contact factory. See note 2.
5
Voltage
Program
(input)
0 – 10V =
0 – Vout
max
Output is programmed externally with a 0 to +10V
signal for 0 to Voutmax. See note 1.
7
Vout Peak
Hold
(output)
0 – 10V =
0 – Vout
max
Peak detect circuit of the output voltage monitor. The
time constant is approximately 5 seconds. See note 1.
8
Vout Monitor
(output)
0 – 10V =
0 – Vout
max
Monitors output voltage. See note 1.
9
+15V @0.1A
(output)
+15V
±
10%
+15VDC for customer interface, maximum output
current is 100mA.
13
End of Charge
Status
Indicator
(output)
High = Charging,
+15V
Low= Load charged
to Voltage Program,
<0.5V
Open collector output rated 30V, 100mA connected to
10kohm pull-up resistor. When the load capacitor
reaches the programmed voltage, pin 13 is pulled low
and latched low, cycling the Inhibit pin 1 resets the
EOC signal.
4, 14, 15
Ground
Ground return for control interface signals.
Notes:
1.
Analog voltage range of 0-5V available per customer request.
2.
Other interface configurations are available to conform to customer requests, contact
Lumina Power for any interface changes.