Lumina Power CCPF-500 Series User Manual Download Page 16

02100005  Rev 1 

CCPF-500 CCPF-750 User Manual 

Page 16 of 17 

 

8.

 

Product Limited Warranty 

Lumina Power, Inc., as Seller, warrants that each Product sold by it is free of defects in materials and 
workmanship. Duration of warranty is as follows:  

a. All Chassis enclosed products are covered for twenty four (24) months from date of shipment. Products 
included but are not limited to the following product families: CCPF,  CCHP, LDY, LDYHC, LDQCW, 
XLB (excluding XLB-300), and MLB. Custom fully enclosed products may be covered for the same 24 
months. Please consult factory for specific terms.  

b. All Open Frame products are covered for 12 months from date of shipment. Open frame power supplies 
are defined as any product that is not enclosed in a metal or plastic enclosure. Products included but are not 
limited to the following product families: LDPC, LDQPC, XLB-300 and any open frame custom products.  

c. All products returned for repair are covered for a period of 6 month or the balance of the original 
warranty, whichever is longer.  

Warranty is not transferable to parties outside of original Buyer's corporate or educational organization. 
Seller will have sole discretion in making determination of validity of warranty if the Product is transferred 
to a different user group than the original Buyer.  

Normal wear and tear and items expendable in normal use are not covered by this warranty. All warranty 
repair or replacement of parts shall be limited to Product malfunctions, which, in the sole opinion of Seller, 
are due or traceable to defects in original materials or workmanship. Such determination will be made when 
the Product is returned to the Seller's factory, transportation prepaid by the Buyer, within the warranty 
period.  

All obligations under this warranty shall cease immediately in the event of abuse, accident, alteration, 
misuse, or neglect of the Product. Use and service of the Product in a manner not in accordance with the 
Owner's Manual (if furnished) will likewise cause all obligations under this warranty to cease. Repaired or 
replacement parts are warranted only for the remaining unexpired portion of the original warranty period 
for the Product. After expiration of the applicable warranty period, Buyer shall be charged at the then 
current prices for parts, labor and transportation.  

Seller has no responsibility under this warranty for the cost of any work (material, labor, and/or other 
expenses) performed by or incurred by Buyer or any third party for modification or repair of the Product 
unless specifically authorized in advance in writing by Seller.  

Reasonable care must be used to avoid hazards. Seller expressly disclaims responsibility for loss or damage 
caused by use of its Products other than in accordance with proper operation procedures.  Other than those 
expressly stated herein, there are no other warranties of any kind, expressed or implied, and specifically 
included but not by way of limitation are the implied warranties of fitness or merchantability for a 
particular purpose.  

It is understood and agreed the seller’s liability whether in contract, in tort, under any warranty, in 
negligence or otherwise shall not exceed the return of the amount of the purchase price paid by the 
purchaser and under no circumstance shall seller be liable for special, indirect, incidental or consequential 
damages. The price stated for the product is a consideration in limiting seller's liability. No action, 
regardless of form, arising out of the transactions of this agreement may be brought by purchaser more than 
one year after the cause of action has accrued.  

Seller’s maximum liability shall not exceed and buyer's remedy is limited to either (i) repair or replacement 
of the defective part of product, or at seller's option (ii) return of the product and refund of the purchase 
price, and such remedy shall be the buyer's entire and exclusive remedy.

 

Summary of Contents for CCPF-500 Series

Page 1: ...Rev 1 CCPF 500 CCPF 750 User Manual Page 1 of 17 26 Ward Hill Ave Bradford MA 01835 Phone 978 241 8260 Fax 978 241 8262 USER MANUAL CCPF 500 XX CCPF 750 XX 500 to 750 J s Capacitor Charging Power Supp...

Page 2: ...etwork Reservoir Charging 12 5 3 Using a CCPF with multiple PFNs or capacitors 13 6 Warnings 14 7 Installation 15 8 Product Limited Warranty 16 9 Service 17 Tables and Figures Table 1 CCPF Interface 6...

Page 3: ...ges up to 4000V where the XX indicates the maximum output voltage As an example a CCPF 500 configured for 1000V maximum output voltage is designated as a CCPF 500 1P where P indicates a positive outpu...

Page 4: ...of Lumina Power Inc are qualified to service this equipment High Voltage Present This power supply produces lethal high voltages Only service personnel of Lumina Power Inc are qualified to service thi...

Page 5: ...actory for voltages 4kVDC Polarity Positive or Negative factory configured Efficiency 80 at full output Regulation 0 5 100Hz Interface Connector 15 Pin D Sub Female 4 Pin Molex interface optional Volt...

Page 6: ...y contact factory See note 2 5 Voltage Program input 0 10V 0 Voutmax Output is programmed externally with a 0 to 10V signal for 0 to Voutmax See note 1 7 Vout Peak Hold output 0 10V 0 Voutmax Peak det...

Page 7: ...02100005 Rev 1 CCPF 500 CCPF 750 User Manual Page 7 of 17 Figure 2 CCPF 500 15 pin Interface Schematic...

Page 8: ...r Applying 10 to 15V to pin 1 prevents the inverter from operating Optional High Enable available contact factory see note 2 NOTE The power supply should be INHIBITED via Pin 1 before the capacitor is...

Page 9: ...02100005 Rev 1 CCPF 500 CCPF 750 User Manual Page 9 of 17 Figure 4 CCPF 500 Mechanical Outline Drawing Dimensions in inches mm in parenthesis...

Page 10: ...05 Rev 1 CCPF 500 CCPF 750 User Manual Page 10 of 17 Figure 5 CCPF 500 Input Side Drawing Dimensions in inches mm in parenthesis Figure 6 CCPF 500 Output Side Drawing Dimensions in inches mm in parent...

Page 11: ...PFN capacitor to the programmed value and then transmit an END OF CHARGE signal to the user Before discharging the load capacitor into the PFN the CCPF should be disabled via the INHIBIT function Once...

Page 12: ...ging In this application the power supply is ENABLED via the INHIBIT function and charges up the capacitor bank to the programmed voltage The IGBT will deliver short high current pulses to the flashla...

Page 13: ...cap from discharge into the other In addition a resistor must be in parallel with each diode to help the power supply to see the cap voltage that is now blocked by the diodes Failure to add the paral...

Page 14: ...ly be connected to supply mains with protective earth Warning Equipment is not suitable for use in presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Warning These pow...

Page 15: ...15 pin D male Optional 4 pin Interface Molex connector 70553 003 mating housing use Molex 50 57 9404 HV Output MHV Female Amphenol 27000 See note below MHV Male and coax cable rated for at least 150 o...

Page 16: ...eglect of the Product Use and service of the Product in a manner not in accordance with the Owner s Manual if furnished will likewise cause all obligations under this warranty to cease Repaired or rep...

Page 17: ...ease MJ 8 28 2017 EK This unit contains no user serviceable parts Service and repair should be performed only by qualified personnel from Lumina Power Inc For more information contact Lumina Power Inc...