7.

 

Installation    

These power supplies are designed for and intended only for installation into OEM pulse 
forming systems.      

 

Only qualified technicians or qualified assemblers may install these power 
supplies.   

 

Only qualified Lumina Power personnel may service these power supplies.   

 

There are no user serviceable parts in this equipment.   

 

Required wire and connectors

:  Refer to Figure 5, CCPF-500 Input Side 

Drawing and Figure 6, CCPF-500 Output Side Drawing for the locations of 
connections.  Table 3, CCPF Connections below shows required cables and 
connectors:  

 

Table 3, CCPF Connections 

Connection 

Description 

Required Wire and Connectors 

AC Input Power 

2 Position Phoenix 

Connector DMKDS2.5 
#10-32 stud for ground 

At least 14AWG wire 

Interface 

15 pin “D” female 

15 pin “D” male 

Optional 4-pin 

Interface 

Molex connector 

70553-003 

mating housing use Molex 50-57-9404 

HV Output 

MHV Female 

Amphenol 27000 

*See note below 

MHV Male and coax cable rated for at 

least 150% of maximum rated output  

voltage of unit 

          * Note: other connectors or flying lead configuration also available,  

contact Lumina Power for any interface changes.     

 

 

Ventilation:

  This unit is forced air cooled via internal DC fans.  A clearance of 

2” should be maintained at either side of the power supply the fan end of the 
power supply as well as the grill side of the power supply.  Hot air exits the grill 
side and should be ducted out of the system.  Do not let the hot air exhaust 
recirculate to the power supply air inlet.  Fully sealed systems should implement a 
heat exchanger system to maintain the environmental conditions list in section 3 
CCPF-500/750-XX Specifications on page 5.

   

 

 

IMPORTANT APPLICATON NOTE REGARDING AC INPUT POWER 

AC Input wires should be at least #14 AWG,  

rated for at least 600V and 105 Degree C. 

Summary of Contents for CCPF-500 Series

Page 1: ...Rev 1 CCPF 500 CCPF 750 User Manual Page 1 of 17 26 Ward Hill Ave Bradford MA 01835 Phone 978 241 8260 Fax 978 241 8262 USER MANUAL CCPF 500 XX CCPF 750 XX 500 to 750 J s Capacitor Charging Power Supp...

Page 2: ...etwork Reservoir Charging 12 5 3 Using a CCPF with multiple PFNs or capacitors 13 6 Warnings 14 7 Installation 15 8 Product Limited Warranty 16 9 Service 17 Tables and Figures Table 1 CCPF Interface 6...

Page 3: ...ges up to 4000V where the XX indicates the maximum output voltage As an example a CCPF 500 configured for 1000V maximum output voltage is designated as a CCPF 500 1P where P indicates a positive outpu...

Page 4: ...of Lumina Power Inc are qualified to service this equipment High Voltage Present This power supply produces lethal high voltages Only service personnel of Lumina Power Inc are qualified to service thi...

Page 5: ...actory for voltages 4kVDC Polarity Positive or Negative factory configured Efficiency 80 at full output Regulation 0 5 100Hz Interface Connector 15 Pin D Sub Female 4 Pin Molex interface optional Volt...

Page 6: ...y contact factory See note 2 5 Voltage Program input 0 10V 0 Voutmax Output is programmed externally with a 0 to 10V signal for 0 to Voutmax See note 1 7 Vout Peak Hold output 0 10V 0 Voutmax Peak det...

Page 7: ...02100005 Rev 1 CCPF 500 CCPF 750 User Manual Page 7 of 17 Figure 2 CCPF 500 15 pin Interface Schematic...

Page 8: ...r Applying 10 to 15V to pin 1 prevents the inverter from operating Optional High Enable available contact factory see note 2 NOTE The power supply should be INHIBITED via Pin 1 before the capacitor is...

Page 9: ...02100005 Rev 1 CCPF 500 CCPF 750 User Manual Page 9 of 17 Figure 4 CCPF 500 Mechanical Outline Drawing Dimensions in inches mm in parenthesis...

Page 10: ...05 Rev 1 CCPF 500 CCPF 750 User Manual Page 10 of 17 Figure 5 CCPF 500 Input Side Drawing Dimensions in inches mm in parenthesis Figure 6 CCPF 500 Output Side Drawing Dimensions in inches mm in parent...

Page 11: ...PFN capacitor to the programmed value and then transmit an END OF CHARGE signal to the user Before discharging the load capacitor into the PFN the CCPF should be disabled via the INHIBIT function Once...

Page 12: ...ging In this application the power supply is ENABLED via the INHIBIT function and charges up the capacitor bank to the programmed voltage The IGBT will deliver short high current pulses to the flashla...

Page 13: ...cap from discharge into the other In addition a resistor must be in parallel with each diode to help the power supply to see the cap voltage that is now blocked by the diodes Failure to add the paral...

Page 14: ...ly be connected to supply mains with protective earth Warning Equipment is not suitable for use in presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Warning These pow...

Page 15: ...15 pin D male Optional 4 pin Interface Molex connector 70553 003 mating housing use Molex 50 57 9404 HV Output MHV Female Amphenol 27000 See note below MHV Male and coax cable rated for at least 150 o...

Page 16: ...eglect of the Product Use and service of the Product in a manner not in accordance with the Owner s Manual if furnished will likewise cause all obligations under this warranty to cease Repaired or rep...

Page 17: ...ease MJ 8 28 2017 EK This unit contains no user serviceable parts Service and repair should be performed only by qualified personnel from Lumina Power Inc For more information contact Lumina Power Inc...

Reviews: