7.
Installation
These power supplies are designed for and intended only for installation into OEM pulse
forming systems.
•
Only qualified technicians or qualified assemblers may install these power
supplies.
•
Only qualified Lumina Power personnel may service these power supplies.
•
There are no user serviceable parts in this equipment.
•
Required wire and connectors
: Refer to Figure 5, CCPF-500 Input Side
Drawing and Figure 6, CCPF-500 Output Side Drawing for the locations of
connections. Table 3, CCPF Connections below shows required cables and
connectors:
Table 3, CCPF Connections
Connection
Description
Required Wire and Connectors
AC Input Power
2 Position Phoenix
Connector DMKDS2.5
#10-32 stud for ground
At least 14AWG wire
Interface
15 pin “D” female
15 pin “D” male
Optional 4-pin
Interface
Molex connector
70553-003
mating housing use Molex 50-57-9404
HV Output
MHV Female
Amphenol 27000
*See note below
MHV Male and coax cable rated for at
least 150% of maximum rated output
voltage of unit
* Note: other connectors or flying lead configuration also available,
contact Lumina Power for any interface changes.
•
Ventilation:
This unit is forced air cooled via internal DC fans. A clearance of
2” should be maintained at either side of the power supply the fan end of the
power supply as well as the grill side of the power supply. Hot air exits the grill
side and should be ducted out of the system. Do not let the hot air exhaust
recirculate to the power supply air inlet. Fully sealed systems should implement a
heat exchanger system to maintain the environmental conditions list in section 3
CCPF-500/750-XX Specifications on page 5.
IMPORTANT APPLICATON NOTE REGARDING AC INPUT POWER
AC Input wires should be at least #14 AWG,
rated for at least 600V and 105 Degree C.