6.

 

Warnings   

 

 

 
 

 

 

 

 

 

 

 

WARNING

:  Only Lumina Power, Inc. qualified service personnel are allowed to 

remove the covers and service this equipment. 

WARNING

NEVER OPERATE THE POWER SUPPLY:

 

1.

 

Without providing adequate protection of personnel from high voltage. 

2.

 

Without proper ground connections. 

3.

 

Without covers and panels properly installed. 

4.

 

With customer interlocks defeated. 

5.

 

Without a suitable load for the application and properly rated for the 
required power dissipation. 

 

Warning:

   

To avoid risk of electric shock, this equipment must only be 
connected to supply mains with protective earth 

Warning: 

Equipment is not suitable for use in presence of a flammable 
anesthetic mixture with air or with oxygen or nitrous oxide. 

Warning: 

These power supplies are not provided with any isolation 
devices and shall only be used inside other equipment that has 
means to isolate its circuits electrically from the supply mains 
on all poles simultaneously.   

High Voltage Present

This power supply produces lethal high voltages.  Only service 
personnel of Lumina Power, Inc., are qualified to service this 
equipment.  Only qualified service personnel are permitted to 
install this power supply.  

Warning: 

This equipment produces high voltages, which can be fatal.  
Only service personnel of Lumina Power, Inc. are qualified to 
service this equipment. 

Summary of Contents for CCPF-500 Series

Page 1: ...Rev 1 CCPF 500 CCPF 750 User Manual Page 1 of 17 26 Ward Hill Ave Bradford MA 01835 Phone 978 241 8260 Fax 978 241 8262 USER MANUAL CCPF 500 XX CCPF 750 XX 500 to 750 J s Capacitor Charging Power Supp...

Page 2: ...etwork Reservoir Charging 12 5 3 Using a CCPF with multiple PFNs or capacitors 13 6 Warnings 14 7 Installation 15 8 Product Limited Warranty 16 9 Service 17 Tables and Figures Table 1 CCPF Interface 6...

Page 3: ...ges up to 4000V where the XX indicates the maximum output voltage As an example a CCPF 500 configured for 1000V maximum output voltage is designated as a CCPF 500 1P where P indicates a positive outpu...

Page 4: ...of Lumina Power Inc are qualified to service this equipment High Voltage Present This power supply produces lethal high voltages Only service personnel of Lumina Power Inc are qualified to service thi...

Page 5: ...actory for voltages 4kVDC Polarity Positive or Negative factory configured Efficiency 80 at full output Regulation 0 5 100Hz Interface Connector 15 Pin D Sub Female 4 Pin Molex interface optional Volt...

Page 6: ...y contact factory See note 2 5 Voltage Program input 0 10V 0 Voutmax Output is programmed externally with a 0 to 10V signal for 0 to Voutmax See note 1 7 Vout Peak Hold output 0 10V 0 Voutmax Peak det...

Page 7: ...02100005 Rev 1 CCPF 500 CCPF 750 User Manual Page 7 of 17 Figure 2 CCPF 500 15 pin Interface Schematic...

Page 8: ...r Applying 10 to 15V to pin 1 prevents the inverter from operating Optional High Enable available contact factory see note 2 NOTE The power supply should be INHIBITED via Pin 1 before the capacitor is...

Page 9: ...02100005 Rev 1 CCPF 500 CCPF 750 User Manual Page 9 of 17 Figure 4 CCPF 500 Mechanical Outline Drawing Dimensions in inches mm in parenthesis...

Page 10: ...05 Rev 1 CCPF 500 CCPF 750 User Manual Page 10 of 17 Figure 5 CCPF 500 Input Side Drawing Dimensions in inches mm in parenthesis Figure 6 CCPF 500 Output Side Drawing Dimensions in inches mm in parent...

Page 11: ...PFN capacitor to the programmed value and then transmit an END OF CHARGE signal to the user Before discharging the load capacitor into the PFN the CCPF should be disabled via the INHIBIT function Once...

Page 12: ...ging In this application the power supply is ENABLED via the INHIBIT function and charges up the capacitor bank to the programmed voltage The IGBT will deliver short high current pulses to the flashla...

Page 13: ...cap from discharge into the other In addition a resistor must be in parallel with each diode to help the power supply to see the cap voltage that is now blocked by the diodes Failure to add the paral...

Page 14: ...ly be connected to supply mains with protective earth Warning Equipment is not suitable for use in presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Warning These pow...

Page 15: ...15 pin D male Optional 4 pin Interface Molex connector 70553 003 mating housing use Molex 50 57 9404 HV Output MHV Female Amphenol 27000 See note below MHV Male and coax cable rated for at least 150 o...

Page 16: ...eglect of the Product Use and service of the Product in a manner not in accordance with the Owner s Manual if furnished will likewise cause all obligations under this warranty to cease Repaired or rep...

Page 17: ...ease MJ 8 28 2017 EK This unit contains no user serviceable parts Service and repair should be performed only by qualified personnel from Lumina Power Inc For more information contact Lumina Power Inc...

Reviews: