22
EN
6. TEChNICAl DATA
Input 1 and 2
Input signals and measuring ranges
Table 1
Sensor type
Standard
Range
Intrin
-
sic
error
Pt100
EN
60751:2009
-200...850 °C
-328...1562 °f
0.2%
Pt500
-200...850 °C
-328...1562 °f
0.2%
Pt1000
-200...850 °C
-328...1562 °f
0.2%
Ni100
-60...180 °C
-76...356 °f
0.2%
Ni1000
-60...150 °C
-76...302 °f
0.2%
Cu100
-50...180 °C
-58...356 °f
0.2%
fe-CuNi (j)
EN 60584-
1:1997
-100...1200 °C
-148...2192 °f
0.3%
Cu-CuNi (T)
-100...400 °C
-148...752 °f
0.3%
NiCr-NiAl (K)
-100...1372 °C
-148...2501.6 °f
0.3%
PtRh10-Pt (S)
0...1767 °C
32...3212.6 °f
0.5%
PtRh13-Pt (R)
0...1767 °C
32...3212.6 °f
0.5%
PtRh30-PtRh6 (B)
0...1767 °C
1)
32...3212.6 °f
1)
0.5%
NiCr-CuNi (E)
-100...1000 °C
-148...1832 °f
0.3%
NiCrSi-NiSi (N)
-100...1300 °C
-148...2372 °f
0.3%
chromel – kopel (l)
GOST R
8.585-2001
-100...800 °C
-148...1472 °f
0.3%
linear current (I)
0...20 mA
0...20 mA
0.2% ±
1 digit
linear current (I)
4...20 mA
4...20 mA
0.2% ±
1 digit
linear voltage (U)
0...5 V
0...5 V
0.2% ±
1 digit
linear voltage (U)
0...10 V
0...10 V
0.2% ±
1 digit
1)
Intrinsic error is related to the measuring range 200…1767 °C
(392...3212,6 °F)