Lumatek CONTROL PANEL PLUS 2.0 Manual Download Page 5

Note!

 Each of the controller’s two channels (Zone A & Zone B) can control up to 

200 Lumatek Control fixtures or ballasts. It is possible to use those channels to 

control fixtures in two separate rooms or to control up to 400 fixtures in one room.

4.  SAFETY GUIDELINES

5.  INSTALLING THE CONTROLLER & FUNCTIONS

5.1 

Preparations

For HID:

Warning!

                 Keep the controller away from fire, excessive heat, water, dust and

contamination. 

Warning! 

                 The Lumatek Digital Control Panel may only be used to control 

compatible Lumatek controllable fixtures and ballasts. Do not connect the 

controller to other products as this may be dangerous and may cause 

malfunctions in the connected equipment. Doing so will void the warranty.  

Warning!

                 Do not open or disassemble the controller, it contains no serviceable

parts. Opening the controller will void the warranty. 

Warning!

 Make sure the signal cables do not touch the reflectors as the

reflectors get very hot! 

 

1.

 Mount the fixtures or ballasts as per your lighting plan.

 Interconnect them as described in the manual for the fixture or ballast     

 using the control cable (TRS) supplied with each controllable fixture or ballast.

      Connect ballast 1 control cable from Out socket of ballast 1 

     to the In socket of ballast 2. 

      Connect ballast 2 control cable from Out socket of ballast 2

     to In socket of ballast 3.  

 4. 

3. 

2. 

Connect all remaining ballasts in series accordingly. 

 5. 

Connect the ballasts or fixtures to the mains.

Summary of Contents for CONTROL PANEL PLUS 2.0

Page 1: ...DUAL SIGNAL LIGHTING CONTROLLER FOR HID LED CONTROL PANEL PLUS MANUAL...

Page 2: ...eys 5 2 2 System settings 5 2 3 Setting signal protocol 5 2 4 Zone parameter settings 5 2 5 Setting pre set Switch ON OFF and light intensity times 5 2 6 Real time On Off switching and adjusting light...

Page 3: ...or up to 50 LED fixtures with analog 0 10V signal It is possible to use each Zone to control fixtures in two independent separate rooms or to control up to 400 fixtures in one room with two different...

Page 4: ...00W 630W 945W 50 100 475W 945W 1000W 60 115 600W 1150W 400 RS485 250W 315W 400W 600W 630W 1000W CONTROLLABLE LED DRIVER TYPE All Lumatek controllable LED drivers 200 RS485 100 0 10V 50 0 10V Adaptor 1...

Page 5: ...and may cause malfunctions in the connected equipment Doing so will void the warranty Warning Do not open or disassemble the controller it contains no serviceable parts Opening the controller will vo...

Page 6: ...res eg Zone A can be set to control 600W LED fixtures and Zone B set to control 465W or 1000W LED fixtures Note Each of the controller s two channels Zone A Zone B can control up to 50 LED fixtures It...

Page 7: ...you can continue to set up the controller Connect controller cable C D from Zone A B output port 3 to Signal In port on LED fixture 1 or ballast 1 IN port Warning The controller may only be connected...

Page 8: ...ed in Type in Zone A B page and W Watts when HID is selected Note LED driver power output is shown as a percentage of the driver s nominal power output eg 50 of a 1000W LED driver is 500W To set Time...

Page 9: ...nt crop damage In ZONE A Press or to Dim and or v to select required temperature to engage auto dim and Press OK to save In ZONE A Press or to Stop and or v to select required temperature to engage au...

Page 10: ...N Lamp is on LED OFF Lamp is off The same reading as 1 The same reading as 2 0 10V LED ON only 0 10V analog signal to both Zones for LED drivers RS485 LED ON only RS485 digital signal to both Zones fo...

Page 11: ...allasts are working together some units are working well but some fail to work Check control cable connections Check if the ballast is faulty Disconnect and reconnect control cable or replace cable Ch...

Page 12: ...ate of purchase If the product shows any defects within this period and that defect is not due to user error or improper use Lumatek Ltd shall at its discretion either replace or repair the product us...

Page 13: ...E A LIGHT SIGNAL OUTPUT INCREASE OR DECREASE PARAMETERS RIGHT SHIFT OK AND SAVE SET SIGNAL PROTOCOL PAGE UP OR PAGE DOWN POWER ADAPTOR INPUT ZONE B THERMO SENSOR INPUT ZONE A THERMO SENSOR INPUT ZONE...

Reviews: