Lumatek CONTROL PANEL PLUS 2.0 Manual Download Page 11

 

CONDITION                        LED STATUS                                       DESCRIPTION

Ballast Locked

Cycle Error

Low Mains

High Mains

Over Temperature

Flash*1

Flash*2

Flash*3

Flash*5

Flash*4

Maximum amount of ignition 

attempts without success 

Lamp stopped for unknown reason

or output signal interrupted. 

Mains Voltage too Low

Mains Voltage too High

Maximum driver temperature exceeded

        FAULT                         INSPECTION METHOD                        TROUBLESHOOTING

Controller doesn’t have

any display after 

connecting to power 

Check the Power Supply

Check the Adaptor

Check the Controller

Waiting for power supply to return

Change the Adaptor

Change the Controller

Ballast output power is 

not same as command 

signal sent from controller

Check the Sun rise and 

set time periods 

Reset or switch off sun rise

/set time period.

Reset temperature 

control values. 

When several ballasts 

are working together, 

some units are working 

well but some fail to work

Check control cable 

connections

Check if the ballast 

is faulty 

Disconnect and reconnect 

control cable or replace cable.

Check LED failure 

indicator on ballast. 

Fail to control ballasts

Check the connection between 

controller and ballasts; 

make sure each connection 

is well-plugged. 

Reconnect the control cables

Controller doesn’t have

any temperature display 

after the temperature 

probe is connected  

Check ‘controller’ LED

on ballast is flashing normally 

Change to another

   temperature probe  

Fail to turn on lamp

Check if the temperature 

probe is damaged. 

Reconnect Cables

8. LUMATEK CONTROLLER TROUBLESHOOTING

Check the temperature 

probe & temperature 

control values set.

Note!

 To reset ballast; disconnect from mains and reconnect after 

30 seconds

Warning! 

When replacing a lamp, always switch Off ballast first by removing 

plug from power supply. Never switch off lamp by removing lamp cable from 

a live ballast.

Summary of Contents for CONTROL PANEL PLUS 2.0

Page 1: ...DUAL SIGNAL LIGHTING CONTROLLER FOR HID LED CONTROL PANEL PLUS MANUAL...

Page 2: ...eys 5 2 2 System settings 5 2 3 Setting signal protocol 5 2 4 Zone parameter settings 5 2 5 Setting pre set Switch ON OFF and light intensity times 5 2 6 Real time On Off switching and adjusting light...

Page 3: ...or up to 50 LED fixtures with analog 0 10V signal It is possible to use each Zone to control fixtures in two independent separate rooms or to control up to 400 fixtures in one room with two different...

Page 4: ...00W 630W 945W 50 100 475W 945W 1000W 60 115 600W 1150W 400 RS485 250W 315W 400W 600W 630W 1000W CONTROLLABLE LED DRIVER TYPE All Lumatek controllable LED drivers 200 RS485 100 0 10V 50 0 10V Adaptor 1...

Page 5: ...and may cause malfunctions in the connected equipment Doing so will void the warranty Warning Do not open or disassemble the controller it contains no serviceable parts Opening the controller will vo...

Page 6: ...res eg Zone A can be set to control 600W LED fixtures and Zone B set to control 465W or 1000W LED fixtures Note Each of the controller s two channels Zone A Zone B can control up to 50 LED fixtures It...

Page 7: ...you can continue to set up the controller Connect controller cable C D from Zone A B output port 3 to Signal In port on LED fixture 1 or ballast 1 IN port Warning The controller may only be connected...

Page 8: ...ed in Type in Zone A B page and W Watts when HID is selected Note LED driver power output is shown as a percentage of the driver s nominal power output eg 50 of a 1000W LED driver is 500W To set Time...

Page 9: ...nt crop damage In ZONE A Press or to Dim and or v to select required temperature to engage auto dim and Press OK to save In ZONE A Press or to Stop and or v to select required temperature to engage au...

Page 10: ...N Lamp is on LED OFF Lamp is off The same reading as 1 The same reading as 2 0 10V LED ON only 0 10V analog signal to both Zones for LED drivers RS485 LED ON only RS485 digital signal to both Zones fo...

Page 11: ...allasts are working together some units are working well but some fail to work Check control cable connections Check if the ballast is faulty Disconnect and reconnect control cable or replace cable Ch...

Page 12: ...ate of purchase If the product shows any defects within this period and that defect is not due to user error or improper use Lumatek Ltd shall at its discretion either replace or repair the product us...

Page 13: ...E A LIGHT SIGNAL OUTPUT INCREASE OR DECREASE PARAMETERS RIGHT SHIFT OK AND SAVE SET SIGNAL PROTOCOL PAGE UP OR PAGE DOWN POWER ADAPTOR INPUT ZONE B THERMO SENSOR INPUT ZONE A THERMO SENSOR INPUT ZONE...

Reviews: