CONDITION LED STATUS DESCRIPTION
Ballast Locked
Cycle Error
Low Mains
High Mains
Over Temperature
Flash*1
Flash*2
Flash*3
Flash*5
Flash*4
Maximum amount of ignition
attempts without success
Lamp stopped for unknown reason
or output signal interrupted.
Mains Voltage too Low
Mains Voltage too High
Maximum driver temperature exceeded
FAULT INSPECTION METHOD TROUBLESHOOTING
Controller doesn’t have
any display after
connecting to power
Check the Power Supply
Check the Adaptor
Check the Controller
Waiting for power supply to return
Change the Adaptor
Change the Controller
Ballast output power is
not same as command
signal sent from controller
Check the Sun rise and
set time periods
Reset or switch off sun rise
/set time period.
Reset temperature
control values.
When several ballasts
are working together,
some units are working
well but some fail to work
Check control cable
connections
Check if the ballast
is faulty
Disconnect and reconnect
control cable or replace cable.
Check LED failure
indicator on ballast.
Fail to control ballasts
Check the connection between
controller and ballasts;
make sure each connection
is well-plugged.
Reconnect the control cables
Controller doesn’t have
any temperature display
after the temperature
probe is connected
Check ‘controller’ LED
on ballast is flashing normally
Change to another
temperature probe
Fail to turn on lamp
Check if the temperature
probe is damaged.
Reconnect Cables
8. LUMATEK CONTROLLER TROUBLESHOOTING
Check the temperature
probe & temperature
control values set.
Note!
To reset ballast; disconnect from mains and reconnect after
30 seconds
Warning!
When replacing a lamp, always switch Off ballast first by removing
plug from power supply. Never switch off lamp by removing lamp cable from
a live ballast.