background image

Warranty void if not installed as per installation instructions

INSTALLATION INSTRUCTIONS

Lumascape Lighting Industries Pty Ltd

38-44 Enterprise Street, Cleveland, QLD 4163, Australia

PO Box 1875, Cleveland D.C., QLD 4163, Australia

  07 3286 2299

F

   07 3286 6599

E

   [email protected]

W

  www.lumascape.com.au 

IN0094 - 28 May 2014

Copyright ©2014 Lumascape Lighting Industries Pty. Ltd.   ABN 21 010 572 773

www.lumascape.com.au

LS431LED: 

Surface Mount Remote Gear 

IP66 / IP67

A.C.N. 0105 72 773

MODEL: 

LS431LED

INPUT VOLTAGE: 

Remote Driver

SPOTLIGHT & FLOODLIGHT

2.

IP67

B

C

A

A

LS6097 remote constant current LED driver 
(or Lumascape approved equivalent)

cable strip length

120 mm

6 mm

4 mm² max per terminal

IP67

B

C

A

A

LS6097 remote constant current LED driver 
(or Lumascape approved equivalent)

cable strip length

120 mm

6 mm

4 mm² max per terminal

Punch gland holes:

 

Depending on your requirements punch out one or two holes and 
install gland(s) as shown in illustration below.

1.

IP67

A

1 or 2

Secure base and tighten entry gland:

 

Drill mounting holes for luminaire. Feed the cable through the gland and 
tighten as shown in illustration. Repeat this process if a secod gland is 
installed. Ensure a correct sized, round cable (

Ø

 5-10 mm) is used or seal 

will not be IP67. Screw down luminaire base. Ensure gasket seal is inserted 
between surface and luminaire base.  
Wire up luminaire to supply cable. Please note that the single colour LED 
luminaire will be supplied with a terminal block. For the RGB verions wire 
nuts (not supplied) must be used to make the connection between the 
luminaire to the supply cable.
Refer to wiring diagram 1.0 for  
conductor colour and designation. 

DANGER

ISOLATE LUMINAIRE FROM POWER

Failure to isolate power 

supply before installation or 

maintenance may result in 

fire, serious injury, electric 

shock, death and may 

damage the luminaire.

1x LS431LED

COMPONENTS

x4

screw

gland

x2

x2

x1

Allen key

gasket seal

All connections must be kept dry; 

failure to do so may result in product 

reliability issues

This is an above ground luminaire and 

no part of it  should be below ground 

level or covered in soil or mulch

CAuTiON: luminaires can become 

very hot. use discretion in placement

WARNiNGS

Refer to Wiring

Diagram(s) 1.0 

COMMON

RED
GREEN
BLUE

DC

RGB Remote Driver

Wire Colour

Designation

Red

Red +

Orange

Red -

Green

Green +

White

Green -

Blue

Blue +

Black

Blue -

Single Colour Low Voltage

Wire Colour

Designation

Yellow

+

Blue

-

Wiring Diagram 1.0

fit gasket seal

Reviews: