General Safety Information

     Failure to comply with the instructions and safety information 

     could result in malfunction of unit, fire hazard or unit, fire 

     hazard, personal injury, and fatal electrical shock hazards. 

     Read all safety information in this manual.

     

WARNING 

 

Disconnect power before installing or servicing. 

     If the power disconnect switch is out of sight, lock it in the open 

     position and tag it to prevent unexpected application of power.

1.  Model 5AY50, 5AY51, 5AY52, and 24K346 should be installed

     indoors. Use only in dry location for 5AY50, 5AY51,  5AY52, 

     and 24K346. Fixture is not waterproof and not intended for use 

     in showers, saunas, or any damp/wet locations. Model 5AY53, 

     24K344, 24K345, and 24K348 can be installed indoors or 

     outdoors, and in wet locations. 

2.  This fixture must be installed in accordance with all electrical 

     and safety codes and ordinances and the most recent National 

     Electric Code (NEC) and the Occupational Safety and Health 

     Act (OSHA).

3.  Make sure the power source meets the requirements of the 

     fixture. All wiring should be performed by a qualified electrician.

4.  To reduce the risk of electric shook, the dock light should be 

     plugged directly to a properly grounded 3-prong receptacle 

     installed in accordance with the National Electric Code, local 

     codes, and ordinances.

5.  Repair or replace damaged cords immediately.

6.  Prevent cord from coming into contact with sharp objects, oils, 

     chemicals, or hot surfaces.

7.  External metal parts of the lamp shade operate with high 

     temperatures. Do not touch external parts of lamp head while 

     fixture is ON. Turn OFF fixture and allow appropriate cooling 

     time before touching lamp shade.

8.  Lamp guard must be in place while fixture is in use.

9.  Do not operate fixture close to combustible materials, or 

     materials affected by heating or drying.

10.This fixture must be installed to minimum 50mm thick wood 

     surface.

     

WARNING

 

 

Potential fatal shock hazard! Do not handle an 

energized fixture or energize any fixture with wet hands or when 

standing on a wet or damp surface, or in water.

     

WARNING

 

 

Do not use in explosive or flammable 

atmospheres.

ADDITIONAL SAFETY INFORMATION FOR MODEL 5AY53 ,

24K344, 24K345 and 24K348 QUARTZ HALOGEN UNITS READ 

ALL INSTRUCTIONS.

     

WARNING

 When portable luminaries are used outdoors, basic 

safety should always be followed to reduce the risk of fire, electric 

shock and personal injury:

A. Use only three wire outdoor extension cords that have three 

     prong grounding plugs and grounding receptacles that accept 

     the appliances plug.

B. Ground Fault Circuit Interrupter (GFCI) protection is to be 

     provided on the circuit(s) to be used for the wet location 

     portable luminaries.

C. Use only with an extension cord to outdoor use, such as 

     extension cord type: SW, SW-A, SOW, SOW-A, STW, STW-A, 

     STOW, STOW-A, SJW, SJW-S, SJOW, SJOW-A, SJTW, 

     SJTW-A, SJTOW, SJTOW-A.

     

WARNING

 lighted lamp is HOT! To reduce the risk of fire, 

electric shock , exposure to excessive UV RADIATION, or injury 

to persons:

1)  Turn off/unplug and allow to cool before replacing bulb.

2)  Bulb gets HOT quickly! Only contact switch/plug when turning 

     up.

3)  Do not touch hot lens, guard or enclosure.

4)  Do not remain in light if skin feels warm.

5)  Do not look directly at lighted lamp.

6)  Do not use bulb of larger wattage than rated on fixture.

7)  Do not touch the bulb at any time. Use a soft cloth. Oil from 

     skin may damage bulb.

8)  Do not operate the portable luminaire with a missing or 

     damaged guard, lamp containment barrier, or UV filter.

MOUNTING- Fixture is designed for wall or post mounting and 

requires a flat vertical surface approximately 3” wide and 5” high. 

Four 3/8” bolts are supplied for mounting.

Fixture is designed for post mounting (24K346 and 24K348 only).

WIRING – Fixture is wired with a 3-wire cord set. All wiring should 

be in accordance with local codes and ordinances. Connection to 

local power should be made using the cord set on the fixture, and 

plugged into a properly grounded receptacle. Ensure that the 

receptacle is located in a manner that the cord remains above the 

dock light arm.

LAMP INSTALLATION 

- Disconnect power before installing or 

removing lamp.

Incandescent units:

1.  Depress the spring loaded pushbutton on the back of lamp 

     shade and screw the lamp into the socket until seated firmly. 

     Slowly release the spring loaded pushbutton.

2.  For lamp replacement, press the spring loaded pushbutton to 

     relieve the spring force on the socket, unscrew the lamp and 

     follow directions stated in step 1.

Note: Maximum wattage is 300 watts.

Quartz Halogen unit:

Insert lamp into socket by holding it with a clean cloth. Ensure that 

both contacts of the lamp are making positive contact with socket 

center contacts.

Note: Maximum wattage is 500 watts. Do not lamp more than 4 

degrees from horizontal when energized.

Warranty

LIMITED ONE- YEAR WARRANTY

Should this product fail to perform satisfactorily due to a defect or 

poor workmanship within ONE YEAR from the date of purchase, 

return it to the place of purchase and it will be replaced, free of 

charge, Incidental or consequential damages are excluded form 

this warranty.

                          Grainger International, Inc. Lake Forest, IL60045

                          Printed in China 06/12

                          FORM#: LT1096

LOADING DOCK LIGHTS

!

!

!

!

!

Summary of Contents for 5AY50

Page 1: ...nit inspect carefully for any damage that may have occurred during transit Check for loose missing or damaged parts Shipping damage claim must be filed with carrier Parts pack for 5AY50 5AY51 5AY52 5AY53 24K344 and 24K345 4 3 8 x 2 L lag screws for securing mounting arm assembly to mounting surface Parts pack for 24K346 and 24K348 1 flat washer ID13 1 flat washer ID15 1 nylon washer ID14 1 nylon n...

Page 2: ...es that accept the appliances plug B Ground Fault Circuit Interrupter GFCI protection is to be provided on the circuit s to be used for the wet location portable luminaries C Use only with an extension cord to outdoor use such as extension cord type SW SW A SOW SOW A STW STW A STOW STOW A SJW SJW S SJOW SJOW A SJTW SJTW A SJTOW SJTOW A WARNING lighted lamp is HOT To reduce the risk of fire electri...

Page 3: ...os B La protección del circuito de falla a tierra GFCI debe ser proporcionado en el circuito s que se utilizará para la ubicación de las luminarias portátiles mojadas C Use sólo con un cable de extensión para uso al aire libre como el tipo de cable de extensión SW SW A SOW SOW A STW STW A STOW STOW A SJW SJW S SJOW SJOW A SJTW SJTW A SJTOW SJTOW A ADVERTENCIA lámpara encendida está CALIENTE Para r...

Page 4: ...air qui ont trois fiches mises à la terre et les récipients de terre qui acceptent la prise appareil B La protection du Ground Fault Circuit GFCI est fourni sur le s circuit s utilisés pour les luminaires portables dans les endroits humides C Utilisez uniquement un cordon à l extension en plein air comme le type des cordons à l extention SW SW A SOW SOW A STW STW A STOW STOW A SJW SJW S SJOW SJOW ...

Reviews: