Communication RS485 & Ethernet
Revision R09, November 2016
33
Reset
RST
0
0; 1
Reboot of the CHM embedded sys-
tem (refer to chapter 8.2.4)
ResetSettings³
RSG
0
0; 1
Reset to factory defaults, refer to
chapter 8.2.4, web-interface: set to
factory defaults)
ReStartNetwork
RSN
0
0; 1 writes new settings in network
configuration file and restarts the net-
work
RS485Number
(old: devicenumber)
RNO
16
0 – 99 (used in RS485 chains)
ServiceMOde³
SMO
0
0; 1 s
witches to servicemode, to
modify „critical“ values.
STandBy
STB
0
0; 1, standby mode with standby tel-
egram, to reduce power consumption
SHuTdown
SHT
0; 1 shutdown CHM system
TimeOutRs485(s)*
TOR
30
5 – 3600
TimeZoneoffsetHours
TZH
0
-12 .... 12 hours, e.g. CET is +1, used
to control window blower
TransferMOde
TMO
0
0 – 9
TransferModeaf-
terError*
TME
0
0 – 9
UAPD
1
0 – 500000, set voltage for APD in
manual APD modes [mV]
UNiT(m/ft)
UNT
m
m, ft
UseALtitude
UAL
0
0; 1
ZEniTh
ZET
0
0 - 90 degree x 100, 0° := vertical
(handled as integer)
Parameter name
short
cmd
standard
value
range / short description
Table 4: list of configurable device parameter; *can be set in service mode;
²in the web interface only, ³by terminal program (RS485).