IRS31Pro-UMB
Operating Manual V10 / 01.2020
G. Lufft Mess- und Regeltechnik GmbH
12
Units:
none
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measured Value
Data Type
min
max
Unit
820
825
Friction
float32
0.0
1.0
6.1.12 Saline Concentration MgCl
2
2
Sampling rate:
see section 5.3
Units:
normalized, % percentage by weight, g/m
2
, lbs. p. l. mile
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measured Value
Data Type
min
max
Unit
830
835
Saline concent.MgCl2
uint16
0
65520
norm value
831
836
Saline concent.MgCl2
float32
0
100
%
911
916
Saline concent.MgCl2
float32
0
100
g/m
2
921
926
Saline concent.MgCl2
float32
0
1280
lbs.p.l.mile
6.1.13 Saline Concentration CaCl
2
2
Sampling rate:
see section 5.3
Units:
normalized, % percentage by weight, g/m
2
, lbs. p. l. mile
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measured Value
Data Type
min
max
Unit
840
845
Saline concent.CaCl2
uint16
0
65520
norm value
841
846
Saline concent.CaCl2
float32
0
100
%
912
917
Saline concent.CaCl2
float32
0
100
g/m
2
922
927
Saline concent.CaCl2
float32
0
1280
lbs.p.l.mile
6.1.14 Road Condition
Sampling rate:
see section 5.3
Units:
logical coding
Request channels:
UMB-Chanel
Measuring Range
act
min
max
avg
Measured Value
Data Type
min
max
Unit
900
905
Road condition
uint8
0
99
Coding
Meaning
Description
10
Dry
There is no liquid water on the road or the water film height is below the dry-
moist threshold.
15
Moist
There is liquid water on the road and the water film height is between the dry-
moist and moist-wet thresholds.
20
Wet
There is liquid water on the road; the water film height has raised above the
moist-wet threshold.
25
Moist with salt
Describes a moist road condition where the freezing temperature is lower than -
0.1°C.
30
Wet with salt
Describes a wet road condition where the freezing temperature is lower than -
0.1°C.
35
Ice
There is frozen water on the road, mostly in the form of ice or snow.
40
Snow
There is snow on the road
45
Frost
There is frost on the road
The factory settings for the moist and wet thresholds are 10 and 200 µm, respectively. These settings can
be adjusted in the sensor configuration (see screenshot).
2