G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Technical Data
Power supply
Power supply
24VDC +/- 10%
Power consumption
< 50mA at 24V; excluding sensor
Connection
Phoenix bus connector, gold, 5 pole
Function display
Green LED, flashes every 10 seconds
RS485 interface internal bus
Standard
RS485 2 wire, half-duplex
Transmission type
Protocol-transparent, 8 data bits, 1 stop bit, no parity
Tri-State
2 bit after stop bit edge
Transmission rate
19200 baud
Connection
Phoenix bus connector, gold, 5 pole, maximum 8A
24V output
max. 2 A (note the maximum current of the internal bus)