MAN019.00
64
24) valves are blocked
6
24 a) valves are blocked at the
output by rubber or other
substances
b)
valves are semi-open due to
the presence of impurities
INCORRECT MOVEMENTS
of the hydraulically driven
members, with respect to the
programmed movements
25) cylinders are blocked
26) excessive loss of force
27) variable pressure at the
accumulators
25 a) internal assembly of the
cylinder is incorrect
b)
loads normal to the axis are
not allowed
c)
seizure of connecting pins
26 refer to point 4
27 a) insufficient accumulator
capacity
b)
increased demand from the
circuit due to internal
leakage
EXCESSIVE WEAR
that is, excessively rapid
compared to the actual time of
operation and the maintenance
carried out
28) oil contains abrasives
29) insufficient lubrication
30) high working pressure
31) faulty connections
28 a) oil is too old
b)
inefficient filters have been
used
29 a) poor quality oil has been
used
b)
oil which is too liquid at the
working pressure has been
used
30 relative to the maximum
pressure allowed for the
pump and for the valves
31 abnormal stress on the shafts
Summary of Contents for SM160B AR
Page 2: ...MAN019 00 2...
Page 3: ...MAN019 00 3 MANUFACTURER AND MACHINE SPECIFICATIONS...
Page 4: ...MAN019 00 4...
Page 20: ...MAN019 00 20 Figure 4 Errore L argomento parametro sconosciuto...
Page 31: ...MAN019 00 31...
Page 37: ...MAN019 00 37 Description of push button control panel...
Page 49: ...MAN019 00 49...
Page 67: ...MAN019 00 67...
Page 69: ...MAN019 00 69 Figure 12 Errore L argomento parametro sconosciuto...
Page 73: ...MAN019 00 73...
Page 75: ...MAN019 00 75 1st TABLE Exploded view of head group code 290551...
Page 77: ...MAN019 00 77 2nd TABLE exploded view of base group code 290552...
Page 79: ...MAN019 00 79 3rd TABLE exploded view A of machine structure code 290553...
Page 83: ...MAN019 00 83 4th TABLE exploded view B of machine structure code 290554 24 23 25 26...
Page 85: ...MAN019 00 85 5th TABLE hydraulic wiring diagram...
Page 86: ...MAN019 00 86 Drawing 6 Power wiring diagram for discharge on one side only...
Page 87: ...MAN019 00 87 Drawing 7 Control wiring diagram 1 for discharge on one side only...
Page 88: ...MAN019 00 88 Drawing 8 Control wiring diagram 2 for discharge on one side only...
Page 92: ...MAN019 00 92...