background image

F. POWER SUPPLIES

Class 2 remote power supplies accommodate varying quantities of fixtures. Power 

supply must be located in a readily accessible location for future servicing.

1. REMOTE POWER SUPPLIES

REMOTE POWER SUPPLY OPTIONS

PART # 

Part ID

PSA-24V-60-XAT2       

 

A

PSA-24V-XX-XXXX  

  B

UBB-JCT-24V-60-XAT2-XXX   C

A

Class 2 power supply dimmable via 0-10V analog, reverse phase or forward phase. 

Domestic version features 1/2” knockouts.

Class 2 power supply and multiple driver options. Domestic version features 1/2” 

knockouts.

Universal back box with 1/2” knockouts, wet and concrete pour rated. Dimmable via 

0-10V analog, reverse phase or forward phase. Can be mounted using specified hanger 

bars or brackets. Available for domestic and international.

B

C

3.00”(76mm)

10.5”(267mm)

4.00”(101mm)

4.700 119.37

4.700 119.38

4.70” 

(119mm)

4.70” 

(119mm)

2.30”(58mm)

10.5” 

(227mm)

2.00”(51mm)

5.38” 

(137mm)

2

1.50”

(38mm)

4.80”

(122mm)

0.80”(20mm)

1.60”

(41mm)

8.30”

(210mm)

1.30”(34mm)

Domestic

International

Domestic

International

Summary of Contents for ISL1

Page 1: ...ly CAUTION Motors Powertools Extensioncords Appliancesorsimilarelectronics A Fixtures to be mounted in conditions where ambienttemperaturesdonotexceed40 C Ensure AC input voltage is protected against...

Page 2: ...mestic version features 1 2 knockouts Class 2 power supply and multiple driver options Domestic version features 1 2 knockouts Universal back box with 1 2 knockouts wet and concrete pour rated Dimmabl...

Page 3: ...gral power supply universal back box or Bollard feature mounting for 1 fixture Universal back box power supply can support multiple fixtures Separate mounting components required for each fixtures 2 I...

Page 4: ...BB Includes back box gasket and SSL UMP mounting plate features 1 2 knockouts on top bottom and back of box SSL BB Collar Length Includes back box gasket and mounting plate with specified collar lengt...

Page 5: ...SSL RM SSL CC 0 69 18mm SSL SC3 SSL SC6 Insert collar into cutout flush with finished substrate fold tabs over to secure Insert collar into cutout flush with finished substrate secure with customer fu...

Page 6: ...e power supply supplied with hanger bars or brackets specified on order SSL1 ISL1 mount horizontally or vertically ISL2 mounts horizontally only SSL1 ISL1 2 40 62mm square cutout ISL2 2 40 62mm H X 4...

Page 7: ...bolts for concrete pour mounting Concrete Pour Secure bollard to base with supplied screws 4 00 102mm Freestanding mount receives luminaire for flush installation available with integral or remote pow...

Page 8: ...e location in either home run or parallel method Home Run Parallel Back boxes used as example of mounting location At each mounting location connect low voltage wiring to factory supplied 6 lead wire...

Page 9: ...d or Surface Mount Box Push wires into cavity junction box and insert fixture as shown below applying even pressure to face of fixture Note If mounting device collar is not flush with substrate spring...

Page 10: ...veraging the fixture if necessary Disconnect pin connector and remove gasket Gasket Remove 3 hex screws and separate LED assembly from fixture Replace with OEM LED assembly sourced through Lucifer Lig...

Page 11: ...assembly STEP 6 Disconnect additional load wiring if applicable STEP 7 Reattach structure wiring to new driver as applies STEP 8 Install driver assembly note that it must be seated on the rear stud an...

Page 12: ...ply retaining clamps screws nuts as apply STEP 4 Remove and replace driver assembly Fig 5 STEP 5 Secure with retaining clamps screws nuts STEP 6 Reattach lines mains load and control wiring with suita...

Page 13: ...le Purple Ground Hot Black Neutral White To EcoSystem Digital Link Or DALI Digital Bus Black Red LED Light Engine Wiring Supplied by Others AT2 0 10 Volt Driver Lucifer Lighting Power Supply Purple Pu...

Page 14: ...ny repairs or modifications other than those made by the Seller This Warranty does not cover damage or failure caused by abnormal spikes in power dirty power and light fixtures used with power supplie...

Reviews: