background image

Brick Hardware Guide (8.0) 

6-9

 

• 

• 

Model 1100

 

• 

• 

Temperature: 0 to 50 C

Shock: 2.5g at 15 - 20 ms on any axis

Relative Humidity: 5 - 95% at 40 C (non-condensing)

Vibration: 5g at 2 - 200Hz on any axis

Non-Operating

Temperature: 0 to 70 C

Shock: 35g at 15 - 20 ms on any axis

Relative Humidity: 5 - 95% at 40 C (non-condensing)

Vibration: 5g at 2 - 200Hz on any axis

Power 

AC Model:

Hot Swappable Internal AC to DC Power Supply: Rated 400 watts max

Auto-ranging: 90 to 254 VAC, 47 - 63Hz

Typical Consumption: 1.2A @ 120VAC; 0.6A @ 240VAC

DC Model

Hot Swappable Internal DC to DC Power Supply: Rated 350 watts max

Input Range: -40 to -60 VDC

Typical Consumption: 2.75A @ -48VDC

Product Safety and Emissions Certifications

Safety Listings

USA – UL1950-1, First Edition

Canada – CAN/CSA C22.2 No. 60950-1-03

EU – EN/IEC 60950

Japan – CB Scheme IEC 60960

EMC Certifications 

USA – FCC Part 15, Class A

Canada – IC-ES003

EU – EN 300386-2; EN 55022, Class A

Japan – VCCI, Class A

ICSA Certification

ICSA V4.0 Firewall Certified

Summary of Contents for VPN Firewall Brick 20

Page 1: ...sion 8 0 1 January 2005 Lucent Technologies Proprietary This document contains proprietary information of Lucent Technologies and is not to be disclosed or used except in Accordance with applicable agreements Copyright 2005 Lucent Technologies Unpublished and Not for Publication All rights Reserved ...

Page 2: ... and on the user is encouraged to try to correct the interference by one or more of the following Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Alteration or modifications c...

Page 3: ...afety Instructions v 1 Model 20 Illustrations 1 2 Specifications 1 3 2 Model 80 Illustrations 2 2 Specifications 2 3 3 Model 150 Lucent Security Management Server LSMS Software Patch 3 1 Illustrations 3 2 LED Indicators 3 3 I O Ports 3 4 Periodic Maintenance 3 4 Specifications 3 5 3 5 3 4 3 4 3 3 3 2 3 1 2 3 2 2 1 3 1 2 v iv iv iii ...

Page 4: ...fications 4 5 5 Model 500 Illustrations 5 1 LAN Indicators 5 3 Specifications 5 3 6 Model 1100 Lucent Security Management Server LSMS Software Patch 6 2 Optimal Interface Selection 6 2 Power Supply 6 3 Illustrations 6 3 Alarm Outputs 6 7 Periodic Maintenance 6 7 Specifications 6 7 A Brick Ports Port Matrix A 1 A 1 6 7 6 7 6 7 6 3 6 3 6 2 6 2 5 3 5 3 5 1 4 5 4 5 4 5 4 2 4 1 ...

Page 5: ...s Model 80 For small to medium sized offices and extranet partners Model 150 For small to medium sized offices and extranet partners Model 350 Available in AC and DC models For enterprise class demands of large corporate facilities Model 500 For enterprise class demands of large corporate facilities Model 1100 Available in AC and DC Models For service providers offering advanced security services ...

Page 6: ...ick to the rack using the brackets on either side and a 2 Phillips head screwdriver 3 If you are installing a Model 20 or 80 connect the power module and external disk drive if equipped to the back The illustrations in Chapters 1 and 2 show the location of the appropriate ports If you are installing a Model 500 take the power cord that came with it and connect it to the back The illustrations in C...

Page 7: ...rack mount cabinet depending on the design are provided for ventilation To ensure reliable operation of the product and to protect it from overheating do not block these slots and openings Installation without sufficient air flow can be unsafe 5 When mounting the equipment in the rack distribute or balance its weight to prevent a hazardous condition due to uneven mechanical loading The rack must s...

Page 8: ...ded by the earthing pin on the input terminal block 10 Ensure that models with DC power inputs are connected to a 48V DC supply source that is electrically isolated from the AC source in compliance with the standard and local jurisdiction authorities of the country where you are installing the product UL1950 UL 60950 in the United States C22 2 No 950 No 60950 in Canada EN IEC60950 in the European ...

Page 9: ...ildings are interconnected the voltage potential might cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this condition exists and if necessary implement corrective action before interconnecting the products 18 If your installation of the equipment requires that you route Ethernet cables between buildings use shielded and earthed Ethernet cable in th...

Page 10: ...viii Brick Hardware Guide 8 0 Introduction ...

Page 11: ... 10 100 Base TX Ethernet interfaces ether0 ether2 It also has a 5VDC connector for the power module and a connector for an external floppy disk drive as well as monitor and keyboard ports The Model 20 comes with an external power module and an optional external 3 5 floppy disk drive NOTE For installation into networks that are subject to surges a shielded ethernet cable and or serial port cable ma...

Page 12: ...ardware Guide 8 0 Model 20 Illustrations Model 20 Three Quarters View Model 20 Front View Model 20 Rear View On Off Switch Power Cable Floppy Disk Drive Serial Port Monitor Ether1 Ether2 Ether0 Keyboard Port Port ...

Page 13: ...ance the datasheet for the Model 20 Brick can be accessed from the Lucent Customer Support web site at http www lucent com support Hardware Assisted Encryption Not applicable Other Ports SVGA video DB9 serial external floppy PS 2 keyboard Cooling Passive Heatsink Altitude 13 123 ft 4 000 meters Environmental Operating Temperature 0 40º C Shock 2 5G at 15 20ms on any axis Humidity 5 95 at 40º C non...

Page 14: ... C non condensing Vibration 5G at 2 200 Hz on any axis Power Input Switching mode 100 240VAC 50 60Hz 20 watts 0 2A 115V 0 1A 230V Output 5VDC 5A External AC to DC power supply rated 25W max Switching Mode 100 240V AC 50 60 Hz Consumption 0 19A typical 115V AC ...

Page 15: ... Safety Listings USA UL 1950 Canada CSA 22 2 No 950 EU EN IEC 60950 Japan CB Scheme 1EC60950 EMC Listings USA FCC Part 15 Class B Canada IC ES003 EU EMC Directive Japan VCCI NEBS Certification Not applicable ICSA Certification ICSA V4 0 Firewall Certified ICSA V1 0B IPSec Certified ...

Page 16: ...1 6 Brick Hardware Guide 8 0 Model 20 ...

Page 17: ... The back has four 10 100 Base TX Ethernet interfaces ether0 ether3 It also has a 5VDC connector for the power module and a connector for an external floppy disk drive as well as monitor and keyboard ports The Model 80 also comes with an external power module and an external 3 5 floppy disk drive NOTE For installation into networks that are subject to surges a shielded ethernet cable and or serial...

Page 18: ...ware Guide 8 0 Model 80 Illustrations Model 80 Three Quarter View Model 80 Front View Model 80 Rear View Power Cable Keyboard Floppy Disk Ether0 Monitor On Off Switch Drive Serial Port Ether1 Ether2 Ether3 Port Port ...

Page 19: ...e TX Ethernet RJ 45 Performance For the latest performance the datasheet for the Model 80 Brick can be accessed from the Lucent Customer Support web site at http www lucent com support Hardware Assisted Encryption Not applicable Other Ports SVGA video DB9 serial external floppy PS 2 keyboard Cooling CPU fan Altitude 10 000 feet 3 048 meters Environmental Operating Temperature 0 40º C Shock 2 5G at...

Page 20: ...W max Input Switching mode 100 250VAC 50 60Hz 27 watts Typical Consumption 0 27A 115V 0 13A 230V Product Safety and Emissions Certifications Safety Listings USA UL1950 Canada CSA 22 2 No 950 EU EN 1EC 60950 Japan CB Scheme 1EC 60950 EMC Certifications USA FCC Part 15 Class A Canada IC ES003 EU EMC Directive Japan VCCI NEBS Certification Not applicable ICSA Certification ICSA 4 0 Firewall Certified...

Page 21: ...rick is only supported by LSMS Version 7 2 or later however software patch 7 2 317 or later is required for Version 7 2 This patch can be downloaded from the following URL http www lucent com security Click on the link on the right side of the page labeled IP Service Product Registration Support Then click on the Private Zone link to access the download page which is only available to registered c...

Page 22: ...3 2 Brick Hardware Guide 8 0 Model 150 Illustrations Model 150 Front View ...

Page 23: ... Alarm Alm this light will be off during normal operation When the temperature of the CPU exceeds specified limits the CPU power supply will be turned off and this light will be red When this occurs the Brick is not functional although the Power HD Activity Ethernet Link and Ethernet Activity lights may still be green Ethernet Link these lights will be solid green as long as a link is established ...

Page 24: ... provides an air filter that is accessible at the side panel The air filter should be periodically frequency is dependent on environment inspected for accumulation of dust debris If dust debris is present the filter should be cleaned by washing it in a sink with liquid soap and warm water the filter is rugged and shaken dry The air filter can be removed cleaned and re installed while the system is...

Page 25: ...pounds 2 3 kg Processor Memory 650 MHz Celeron Processor with 128 MB of RAM LAN Interface Four 10 100base TX Ethernet Ports Performance For information on the Brick 150 performance specifications please access the following website http www lucent com security Hardware Assisted Encryption Built in accelerator chips Other Ports SVGA video Parallel DB9 serial USB 2 Cooling CPU Chassis Power Supply A...

Page 26: ...n 5g at 2 200Hz on any axis Power External AC to DC Power Supply rated 50W max Input CV mode 100 240 VAC 47 to 63 Hz 64 watts Typical consumption 0 28 A 115V 0 14A 230V Product Safety and Emissions Certifications Safety Listings USA Canada CSA Certified to UL60950 1 First Edition and CAN CSA 22 2 No 60950 1 03 EU CE CB Scheme to EN 1EC 60950 EMC Certifications USA FCC Part 15 Class B Canada IC ES0...

Page 27: ...n the AC model Lucent Security Management Server LSMS Software Patch The Model 350 Brick is only supported by LSMS Version 7 1 or later however software patch 179 or greater is required for Version 7 1 This patch can be downloaded from the following URL http www lucent com security Click on the link on the right side of the page labeled IP Service Product Registration Support Then click on the Pri...

Page 28: ...ide 8 0 Model 350 Illustrations Model 350 AC model with EAC Front View Model 350 AC model without EAC Front View Power Switch Power Light EA Act Light FD Act Light Disk Drive Power Switch Power Light FD Act Light Disk Drive ...

Page 29: ... unit boots up and the EA board passes internal diagnostics it will turn solid green In addition to the three lights above the DC model also has the following activity lights on the front panel The Fault light will turn amber when power is lost to either the A or B power connector The Audio Cut Off Activity ACO Activity light is amber when a fault still exists but the audio alarm has been disabled...

Page 30: ... of the I O connections Parallel Port Ether0 Ether1 Monitor Port Serial Port USB Ports Keyboard Port Ground Ether7 Ether6 Ether5 Ether4 Ether3 Ether2 Power Receptacle Serial Port Parallel Port USB Ports Keyboard Port Monitor Port Ether0 Ether1 Alarm Connectors Ether4 Ether3 Ether2 Ether7 Ether6 Ether5 48VA Conn 48VB Conn Primary Ground ...

Page 31: ...anel The air filter should be periodically frequency is dependent on environment inspected for accumulation of dust debris If dust debris is present the filter should be cleaned by washing it in a sink with liquid soap and warm water the filter is rugged and shaken dry The air filter can be removed cleaned and re installed while the system is running Specifications Dimensions Height 1 75 inches 4 ...

Page 32: ...CV2 module standard w DC model optional w AC model Other Ports SVGA video parallel DB9 serial PS 2 keyboard USB 3 Cooling CPU chassis power supply fan Altitude Up to 13 123 feet 4 000 m Environmental Operating Temperature 0 to 50 C Shock 2 5g at 15 20 ms on any axis Relative Humidity 5 95 at 40 C non condensing Vibration 5g at 2 200Hz on any axis Non Operating Temperature 0 to 70 C Shock 35g at 15...

Page 33: ...rtifications Safety Listings USA Canada CSA Certified to UL60950 1 First Edition and CAN CSA 22 2 No 60950 1 03 EU CE CB Scheme to EN 1EC 60950 EMC Certifications USA FCC Part 15 Class A Canada ICES003 EU CE EN 300 386 2 EN 55002 Class A Japan VCCI Class A ICSA Certification ICSA V4 0 Firewall Certified ICSA V1 0B IPSec Certified Other Certifications DC model only NEBS Level 3 compliant to Telecor...

Page 34: ...4 8 Brick Hardware Guide 8 0 Model 350 ...

Page 35: ...contains 14 10 100 Base TX Ethernet ports and 1 Gigabit Fiber port A hardware based Encryption Accelerator Board can be optionally added Illustrations Model 500 Front View The front bezel contains four activity lights The Power PWR light will turn solid green when the Model 500 is powered on by the switch in the rear NOTE For installation into networks that are subject to surges a shielded etherne...

Page 36: ...or Board then this light will remain dark If the unit is equipped with the EA board it boots up and the EA board passes internal diagnostics then this light will light solid green Once the unit is booted the EA Act light will flash when there are encrypted packets entering or leaving the unit Model 500 Rear View Power Keyboard port Monitor port E1 E0 Disk drive Console port E8 E9 E13 Momentary Eth...

Page 37: ...cessor Memory Pentium III 1 26GHz with 256MB of RAM LAN Interfaces Ethernet 14 10 100 Base TX Ethernet RJ45 Fiber Gigabit Interface 1 Port LED on Left LED on Right Color Color Ethernet 0 1 Green ON 100 Mbps OFF 10 Mbps Yellow ON Link Integrity BLINKING activity Ethernet 2 7 Green ON 100 Mbps OFF 10 Mbps Green ON Link Integrity BLINKING activity Ethernet 8 13 Green ON Link Integrity BLINKING Activi...

Page 38: ...celerator EACV2 module Other Ports SVGA video DB9 serial PS 2 keyboard Cooling CPU chassis power supply fan Altitude Up to 13 123 feet 4 000 m Environmental Operating Temperature 0 to 45 C Shock 2 5g at 15 20 ms on any axis Relative Humidity 5 95 at 40 C non condensing Vibration 5g at 2 200Hz on any axis Non Operating Temperature 40 to 70 C Shock 35g at 15 20 ms on any axis Relative Humidity 5 95 ...

Page 39: ...Emissions Certifications Safety Listings USA UL1950 Canada CSA 22 2 No 950 EU EN 1EC 60950 Japan CB Scheme 1EC60950 EMC Certifications USA FCC Part 15 Class A Canada IC ES003 EU EN300 386 2 EN 55022 class A Japan VCCI class A ICSA Certification ICSA V4 0 Firewall Certified ICSA V1 0B IPSec Certified NSA Certification National Security Agency EAL2 Government Protection Profile Certified ...

Page 40: ...5 6 Brick Hardware Guide 8 0 Model 500 ...

Page 41: ...itFiber ports and three Encryption Accelerator Cards 7 1 4 3 configuration Seven 10 100baseTX ports one GigabitCopper port six GigabitFiber ports and two Encryption Accelerator Cards 7 1 6 2 configuration The DC Model can be purchased in the following configuration Seven 10 100baseTX ports one GigabitCopper port four GigabitFiber ports and three Encryption Accelerator Cards 7 1 4 3 configuration R...

Page 42: ...erface Selection This section pertains to performance considerations of different interfaces within a single Model 1100 If you have purchased the 7 1 4 3 configuration then this section does not apply and you should immediately skip this section If you have purchased the 7 13 0 2 or 7 1 6 2 configuration the performance of the Brick will be faster with certain wiring configurations The best perfor...

Page 43: ...del 1100 AC model Front View CAUTION Before connecting power the Model 1100 chassis must be properly grounded Two 8 32 threaded studs spaced one inch apart are provided at the rear of the chassis for grounding purposes Use copper 14 AWG wire Disk Activity Light Door Lock Access to Fan Cover screw Momentary On Switch Power Light Fault Indicator Light Floppy Disk Drive ...

Page 44: ...Drive ETHER8 ETHER10 ENCRYPTION ACCELLERATOR CARD 1 ENCRYPTION ACCELLERATOR CARD 0 ENCRYPTION ACCELLERATOR CARD 2 MONITOR CONSOLE KEYBOARD USB PARALLEL ETHER7 ETHER0 ETHER11 ETHER9 ETHER6 ETHER5 ETHER2 LED LED LED ETHER3 ETHER4 ETHER1 OFF INACTIVE ON ACTIVE ON ACTIVE OFF INACTIVE ON ACTIVE OFF INACTIVE Power Connections Parallel Port ACO Switch Ether7 Gigabit Copper Port Secondary Ground Power Mod...

Page 45: ...ION When this unit is powered by 48 V dc voltage sources the following applies This equipment is to be installed in restricted access areas in business and customer premises applications Installation must include an Independent Frame Ground Drop to Building Ground ATTENTION Lorsque cet appareil est alimenté par une source de 48 V c c ce qui suit s applique Lorsqui il est exploité dans un bureau ou...

Page 46: ... ACTIVE LED ENCRYPTION ACCELLERATOR CARD 2 OFF INACTIVE ON ACTIVE LED ETHER3 ETHER5 ETHER6 ETHER4 ETHER1 ETHER2 Gigabit Fiber Ports Encryption Accelerator Cards 10 100base TX Ports ENCRYPTION ACCELLERATOR CARD 0 ETHER11 ETHER10 ETHER12 ETHER13 ETHER3 ETHER5 ETHER6 ETHER4 ETHER1 ETHER2 LED OFF INACTIVE ON ACTIVE ENCRYPTION ACCELLERATOR CARD 1 ON ACTIVE OFF INACTIVE LED ETHER9 ETHER8 Gigabit Fiber P...

Page 47: ...d will not reactivate until the existing alarm has been cleared and a new alarm has been generated Periodic Maintenance The LVF Brick provides an air filter that is accessible at the front panel The air filter should be periodically frequency is dependent on environment inspected for accumulation of dust debris If dust debris is present the filter should be cleaned by washing it in a sink with liq...

Page 48: ...or cards 7 1 6 2 Configuration Seven 10 100 Base TX ports One gigabit copper port Six gigabit fiber ports Two encryption accelerator cards Performance For the latest performance the datasheet for the Model 1100 Brick can be accessed from the Lucent Customer Support web site at http www lucent com support Hardware Assisted Encryption Optional Encryption Accelerator module Other Ports SVGA video DB9...

Page 49: ...C to DC Power Supply Rated 400 watts max Auto ranging 90 to 254 VAC 47 63Hz Typical Consumption 1 2A 120VAC 0 6A 240VAC DC Model Hot Swappable Internal DC to DC Power Supply Rated 350 watts max Input Range 40 to 60 VDC Typical Consumption 2 75A 48VDC Product Safety and Emissions Certifications Safety Listings USA UL1950 1 First Edition Canada CAN CSA C22 2 No 60950 1 03 EU EN IEC 60950 Japan CB Sc...

Page 50: ...6 10 Brick Hardware Guide 8 0 Model 1100 ICSA V1 0B IPSec Certified ...

Page 51: ...ype on all LVF Brick models Table 1 Number of Ports on LVF Bricks Model Configuration Number of Ports 10 100 Base TX Gigabit Copper Gigabit Fiber LC Type Gigabit Fiber SC Type 20 3 0 0 0 80 4 0 0 0 150 4 0 0 0 201 4 0 0 0 300 8 0 0 0 350 7 1 0 0 500 14 0 1 0 1000 9 2 9 0 0 2 1000 7 2 7 0 0 2 1000 5 4 5 0 0 4 ...

Page 52: ...VF Bricks Model Configuration Number of Ports 10 100 Base TX Gigabit Copper Gigabit Fiber LC Type Gigabit Fiber SC Type NOTE All copper ports use standard RJ45 connectors NOTE All Gigabit Fiber ports are multimode NOTE For installation into networks that are subject to surges a shielded ethernet cable and or serial port cable may be needed for regulatory compliance ...

Reviews: