Configuring a CellPipe SDSU
Configuring WAN interface
CellPipe™ SDSU User’s Guide
4-3
3
Select
Configure Physical Interface
.
4
Select
Enable/Disable Conexant Autobaud Mode
.
5
Select to enable Autobaud Mode.
Configuring for ATM
Transmission via SDSL on the CellPipe SDSU requires you to configure the WAN
interface to run either ATM or Frame Relay datalink protocol.
To configure for ATM, proceed as follows:
1
From the Main Menu, select
Configure Interface
.
2
Select
SDSL
.
3
Select
Configure Datalink Protocol
.
4
Select
ATM
.
Configuring PVCs
When running ATM as your data link protocol, you need to configure each PVC
connection you use. You can have up to seven PVC connections with each PVC
establishing a port.
To configure a PVC port, proceed as follows:
1
From the Main Menu, select
Configure Interface
.
2
Select
SDSL
.
3
Select
Configure PVCs
.
4
Select
Add new PVC
.
5
Enter VPI/VCI for each port you want to configure.
6
Select
RFC 1483 (with LLC Encapsulation)
for ATM encapsulation.
Payload scrambling
You must enable payload scrambling when using ATM datalink protocol to connect to
a digital subscriber line access multiplexer (DSLAM), which usually has payload
scrambling set as default.