15 

 

 

 

 
 

 

All electric motors, including fans make some noise and may feel hot if touched

—this is not a fault. 

 

Some fan wobble more than other

—even in the same model.   

 

Fan lights can rattle, but are not covered under warranty 

 

Fan wall controller make slight buzz and get warm especially on lower setting 
These occurrences are not covered by the manufacturer’s warranty.   

 
 
 
 
 
 

AIRLIE ECO 

SERIES models 

Rated Voltage 

Rated power 

(motor) 

Rated power lamp (for 

models with light only) 

Lamp type 

 

48

” fan with light 

230-240 VAC 

65W 

MAX. 2 x 15W CFL Spiral 
Only 

E27

 

48

” fan without 

light 

230-240 VAC 

65W 

N/A   

N/A

 

52

” fan with light 

230-240 VAC 

65W 

MAX. 2 x 15W CFL Spiral 
Only   

E27

 

52

” fan without 

light 

230-240 VAC 

65W 

N/A 

N/A 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NOTES TO INSTALLERS 

TECHINCAL INFORMATION 

Summary of Contents for AIRFUSION AIRLIE ECO SERIES

Page 1: ...EILING FAN MANUAL INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION LUCCI AIRFUSION AIRLIE ECO SERIES E27 LAMP HOLDER CEILING FANS CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND F...

Page 2: ...it s fixing must be able to support the moving weight of the fan and must not twist or work loose 6 The fan must be earthed 7 Do not connect the fan motor to a dimmer switch This may give an unsatisfa...

Page 3: ...and can attract a service charge MECHANICAL NOISE MAY BE NOTICED ON INSTALLATION ALLOW AT LEAST 8 HOURS SETTLING IN PERIOD SOME FANS WOBBLE MORE THAN OTHERS EVEN IN THE SAME MODEL IT DOES NOT MEAN THE...

Page 4: ...1 Blades x 4 1 Blades x 4 2 Pre assembled Fan motor down rod and canopy x 1 2 Pre assembled Fan motor down rod and canopy x 1 3 Glass shade x 1 3 Hanger Bracket x 1 4 Hanger Bracket x 1 4 Flat washers...

Page 5: ...s Step ladder Wire cutter Wiring supply cable as required by AS NZS 3000 wiring code 1 The ceiling fan must be installed in a location so that the blades are at least 2 1 meters above the floor and 30...

Page 6: ...in Fig 6 NOTE FOR FAN MODELS WITHOUT LIGHT IGNORE THIS INSTALLATION PROCESS 7 Carefully place the glass shade cover over the lamp and twist clockwise to lock it The glass shade must be inserted corre...

Page 7: ...TAKEN BY A LICENCED ELECTRICIAN NOTE AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING Fig 8 Wiring diagram NOTE The light switch wiring diagram is omitted for models th...

Page 8: ...8 Fig 9 Rotary switch and controller capacitor wiring diagram Fig 10 Secure the canopy with screws...

Page 9: ...h light via the wall controller Refer to Fig 11 SWITCH POSITION DESCRIPTION OFF FAN IS OFF 1 FAN IS ON SPEED HIGH 2 FAN IS ON SPEED MEDIUM 3 FAN IS ON SPEED LOW LIGHT SWITCH Toggle to switch ON OFF th...

Page 10: ...light can be switched ON OFF via the light switch on the Wall Controller Fig 11 Changing lamp or Re lamping When changing or re lamping for your safety the following should be considered 1 Switch OFF...

Page 11: ...e as this can cause the blade tip to be unlevelled An out of shape blade can cause wobbling Check by removing the blade and lay it on a flat surface A good flat blade will lay flat on the surface 3 Bl...

Page 12: ...or less than others Threaded components working slighting loose or blade carriers even slightly bent due to vigorous cleaning or bumping can cause extra wobble and noise THIS IS NOT COVERED UNDER WARR...

Page 13: ...systems there is usually a dual tariff meter installed or dual meters A smaller control box marked Zellweger may also be present The meter or Zellweger box will usually have the ripple control signal...

Page 14: ...g section of manual The blade may require adjustment at the blade mounting screws The blade is out of shape thus causing wobbling New blades set will require to be replaced Contact your local Beacon L...

Page 15: ...pecially on lower setting These occurrences are not covered by the manufacturer s warranty AIRLIE ECO SERIES models Rated Voltage Rated power motor Rated power lamp for models with light only Lamp typ...

Page 16: ...y changes to ceiling fan blade or motor plated and or painted finishes due to climatic conditions moisture salt air etc or after 6 months from the date of purchase or other circumstances deemed to be...

Page 17: ...in material The replacement of the blades is not covered by the in home warranty service call Notification within 48 hours of installation is required where blades have found to be broken on unpackin...

Page 18: ...uct was installed by a licensed electrical contractor 4 A copy of the original receipt of purchase is presented 5 12 month warranty applies when used in any non domestic applications 6 This warranty d...

Page 19: ...and warranty purposes NAME ADDRESS POSTCODE MODEL NUMBER PO DATECODE Sticker here PO NUMBER or DATECODE DATE OF PURCHASE INSTALLING LICENSED ELECTRICAN LICENCE No ATTACH PROOF OF PURCHASE HERE THIS CO...

Reviews: