The fan must be installed so that the blades are more than 2.1 meters above the floor.
According to law in Australia, all electrical connections & disconnection must be installed by licensed
electrician. This ceiling fan is within this requirement.
According to our warranty terms, only the fans installed by licensed electrician are covered by warranty
service.
WARNING: THE CEILING FAN MUST BE SWITCHED OFF, BEFORE TROUBLE
SHOOTING IS PERFORMED.
TROUBLE
PROBABLE CAUSES
SUGGESTED REMEDY
1. Fan will not start
(Warning:
THE ceiling must
be switched OFF, and the
assistance of a licensed
electrician maybe required
.)
A. Fuse or circuit breaker blown.
Check main and branch circuit fuses or
circuit breakers.
B. Loose power line connections to
the fan.
Check line wire connections to fan
C. Speed controller not in correct
position.
Check speed controller’s position.
2. Fan Wobbles
(Refer to Wobble section of
the
manual
for
further
information.)
A. Fan blades are not horizontal to
ceiling.
Refer to “wobbling fixing” section of
manual.
-
The blade may require adjustment
at the blade mounting screws;
-
The blade is out of shape, thus
causing wobbling. New blades set
will require to be replaced. Contact
your local Beacon Lighting store.
B. Blade screws are loose.
Make sure all screws are securely
fastened.
C. Blade/s are out of shape
Remove blade and lay on a flat surface to
check if blades are out-of-shape. Contact
agent or manufacturer for replacement
blades.
3. Fan sound noisy
A. Top canopy touching ceiling.
Lower canopy from ceiling to ensure
minimum 3 mm clearance.
B. Loose fan blade screws.
Re-tighten all screws on fan blades but
never over-tighten.
C. Ceiling fan not secured against
ceiling.
Re-tighten all screws in the hanging
bracket or plate.
D. Incorrect speed controller.
Change the controller to the one supplied.
E. Audible buzzing noise. Cause by
Ripple Control signals. Please refer
to the Ripple Control section of this
manual.
Install a Ripple Control filter. (Refer to the
Ripple control information in this manual.)
4. Mechanical Noise
A. Allow at least 8 hours settling-in
period.
5. Light will not turn ON
(Optional light kit ONLY)
The globe/lamp has failed.
Replace globe/lamp
TROUBLE-SHOOTING CHECKLIST
WARNING