Airfusion Akmani Installation Instructions
7 |
P a g e
USING YOUR CEILING FAN
Pairing Transmitter and Receiver
– when 2 or more DC ceiling fans are installed in one location
When two or more fans are located near each other, you may want to have the receiver/transmitter for each fan set to a
different code, so that the operation of one fan does not affect the operation of the other fan/s.
The DIP switches for the transmitter (remote hand piece) are located in the battery compartment of the transmitter.
Configuring the DIP switches will allow a unique transmission code assigned to each ceiling fan.
NOTE:
Ensure that you have installed an all - pole disconnection switch in the fixed wiring for each fan, when using DIP
code function.
NOTE:
Ensure power to the Receiver is
ON
prior to pairing the transmitter with the receiver.
Transmitter/Receiver pairing for ceiling fan 1:
Turn off both ceiling fans 1 and 2 via the mains supply to the receiver.
Slide the cover of the battery compartment of the transmitter to access the DIP switches. This will be transmitter
1.
Change the position of the DIP switches in the remote transmitter 1, so that it will be different to transmitter 2.
Fig. 11
Install the 12VDC battery in the compartment. Please make sure the polarity of the battery is correct.
Turn on the power to receiver 1. Keep the power OFF to receiver 2. (Each ceiling fan must have its own isolation
switch, so that only the ceiling fan that needs to be paired with the transmitter will be ON).
Press and hold the “
” button on
transmitter 1
for 5 seconds within 30 seconds of switching the power to the
receiver of ceiling fan 1.
Once the transmitter is paired with the receiver of ceiling fan 1, it will make a beep sound twice. Turn ON/OFF or
change the speed of the ceiling fan 1 by the transmitter to check the operation.
Fig. 10