background image

macnaught.com

3     

Lubemate | Digital Preset Oil Control Gun

INSTRUCTION MANUAL

GENERAL SAFETY REGULATIONS

1. Keep the work area clean and dry. Damp or  
wet work areas can result in injury.
2. Keep children away from work area. Do not 
allow children to handle this product.
3. Use the right tool for the job. Do not attempt 
to force small equipment to do the work of larger 
industrial equipment. There are certain applications 
for which this equipment was designed. It will 
do the job better and more safely at the capacity 
for which it was intended. Do not modify this 
equipment, and do not use this equipment for  
a purpose for which it Was not intended.
4. Check for damaged parts. Before using this 
product, carefully check that it will operate 
properly and perform its intended function.  
Check for damaged parts and any other conditions 
that may affect the operation of this product. 
Replace damaged or worn parts immediately.
5. Do not overreach. Keep proper footing and 
balance at all times to prevent tripping, falling, 
back injury, etc.
6. DO NOT use the equipment when tired or under 
the influence of drugs, alcohol, or medication. 
A moment of inattention while operating this 
equipment may result in serious personal injury.

IMPORTANT!  

This manual contains important warnings and  
information. READ AND KEEP IT FOR REFERENCE.

SAFETY PRECAUTIONS

 

WARNING!

Precaution before installation:
1.
 Check if there is any data shown on the display.
2. Check if the trigger can work normally.
3. Check if the oil inlet can rotate well.

INTENDED USE

Oil preset meter can be used to dispense motor 
oil. With the pre-selected function, the nozzle 
automatically closes the valve and stops dispensing.

 

WARNING  

Read carefully and understand all INSTRUCTIONS 
before operating. Failure to follow the safety 
rules and other basic safety precautions may 
result in serious personal injury. Save these 
instructions in a safe place and on hand so that 
they can be read when required. Keep these 
instructions to assist in future servicing.

AREA 4:

 

FOR BATTERY CAPACITY

AREA 2:

 FOR MEASUREMENT UNITS

Value

ER14250 3.6V 

1-35L/min 
0.5-100bar 

Data

Flow rate

Operating Pressure Range

60°C

±0.5%

Accuracy

Battery

Max operation temperature

1

2

3

4

5

6

Fig. 2

1. Air supply

2. Shut off air valve

3. Oil Pump

4. Shut off oil valve

5. Hose reel

6. Oil control valve 

Display and button usage

 

Notes: It will flashing when

battery voltage less than 3.3V;

AREA 1:

 

FOR LAST DISPENSE CYCLE

AREA 3:

 

FOR ACCUMULATED TOTAL

Menu:

 

MOVING THE NUMBERS FOR

ADJUSTING THE CALIBRATION 

AND CHOOSING THE UNITS

Reset:

 

CHOOSING THE UNITS AND 

SETTING CORRECTION FACTOR

AREA 4:

 

FOR BATTERY CAPACITY

AREA 2:

 FOR MEASUREMENT UNITS

Value

ER14250 3.6V 

1-35L/min 
0.5-100bar 

Data

Flow rate

Operating Pressure Range

60°C

±0.5%

Accuracy

Battery

Max operation temperature

1

2

3

4

5

6

Fig. 2

1. Air supply

2. Shut off air valve

3. Oil Pump

4. Shut off oil valve

5. Hose reel

6. Oil control valve 

Display and button usage

 

Notes: It will flashing when

battery voltage less than 3.3V;

AREA 1:

 

FOR LAST DISPENSE CYCLE

AREA 3:

 

FOR ACCUMULATED TOTAL

Menu:

 

MOVING THE NUMBERS FOR

ADJUSTING THE CALIBRATION 

AND CHOOSING THE UNITS

Reset:

 

CHOOSING THE UNITS AND 

SETTING CORRECTION FACTOR

AREA 4:

 

FOR BATTERY CAPACITY

AREA 2:

 FOR MEASUREMENT UNITS

Value

ER14250 3.6V 

1-35L/min 
0.5-100bar 

Data

Flow rate

Operating Pressure Range

60°C

±0.5%

Accuracy

Battery

Max operation temperature

1

2

3

4

5

6

Fig. 2

1. Air supply

2. Shut off air valve

3. Oil Pump

4. Shut off oil valve

5. Hose reel

6. Oil control valve 

Display and button usage

 

Notes: It will flashing when

battery voltage less than 3.3V;

AREA 1:

 

FOR LAST DISPENSE CYCLE

AREA 3:

 

FOR ACCUMULATED TOTAL

Menu:

 

MOVING THE NUMBERS FOR

ADJUSTING THE CALIBRATION 

AND CHOOSING THE UNITS

Reset:

 

CHOOSING THE UNITS AND 

SETTING CORRECTION FACTOR

FACTORY SETTINGS

•  

Each meter is preprogrammed and calibrated at the factory. Each meter is programmed in quarts for 
use with motor oil as standard. The meter is shipped in the Manual Mode. 

•  The factory preset cannot be changed. 

TOOL USE

•  DO NOT modify or alter the meter.
•  DO NOT leave the meter unattended while dispensing.
•  Check the meter daily. Worn or damaged parts should be repaired or replaced immediately.
•  DO NOT exceed the maximum working pressure level of the lowest rates system component.
•  Use only extensions and nozzles that are compatible with this meter.
•   Use only fluids and solvents that are compatible with the equipment.  

Notice the warnings for fluids and solvents.

•  Tighten all fluid connections before operating the meter.
•  Comply with all local, state, and federal fire, electrical and safety regulations.
•   Use of the product in a manner other than specified in this manual may result in bodily  

injury or impaired operation or damage to the meter. 

OPERATION

The Digital Meter requires 1 Alkaline cell 9V battery to operate (battery included). For battery 
replacement, refer to Section D, Battery Replacement elsewhere in this manual.

TECHNICAL DETAILS

Item No.

L-DPOCG 

Flow Range 

1-35L/min (0.3-9.2 GPM) 

Operating Pressure Range 

7-1000 PSI 

Operating Temperature 

Max. 60°C 

Accuracy 

±0.5% 

Viscosity 

8-5000 mPas 

5-Digital LCD Display (3/8"H x 3/16"W) 

Quart, Pint, Gallon, Liter 

Inlet Connection 

1/2" BSP (F) 

Power Source 

1 Alkaline cell 9V 

*Tested with DTE-25 motor oil at ambient temperature. Min.-Max. flow range will vary with fluid viscosity. 

AUTO
Press to enter and exit the AUTO Mode. 

RESET      
Press in Manual or AUTO Mode to clear 
the previously programmed batch and to 
reset the meter. 

OK/STOP    
Press to confirm the Valve and to stop 
the flow through a mechanical override.

AUTO

10

1

0.1

RESET

OK/STOP

Press to enter and exit the AUTO Mode. 

1. Keypad buttons

 

MAC0619_Lubemate_InstructionManual_L-DPOCG_D2.indd   3-4

7/8/18   4:43 pm

Summary of Contents for L-DPOCG

Page 1: ...uto shut off gun with totaliser and batch counters 1 2 BSP F inlet swivel Flow range 1 35LPM TECHNICAL SPECIFICATIONS Robust light weight design Ergonomic plastic shell with shockproof rubber the trigger guard prevents accidental operation High accuracy digital oil meter 5 digit easy to read resettable LCD display Flexible extension with auto nozzle Easy access in tight spaces and auto nozzle avoi...

Page 2: ...y Battery Max operation temperature 1 2 3 4 5 6 Fig 2 1 Air supply 2 Shut off air valve 3 Oil Pump 4 Shut off oil valve 5 Hose reel 6 Oil control valve Display and button usage Notes It will flashing when battery voltage less than 3 3V AREA 1 FOR LAST DISPENSE CYCLE AREA 3 FOR ACCUMULATED TOTAL Menu MOVING THE NUMBERS FOR ADJUSTING THE CALIBRATION AND CHOOSING THE UNITS Reset CHOOSING THE UNITS AN...

Page 3: ...PT 1 2 BSP depending on meter model Attach the hose 1 On the opposite end apply sealant to the end of the nozzle 2 Thread the nozzle onto the meter Screw it in tightly with an open ended adjustable wrench 3 Open all dispense position shut off valves start the pump to pressurize system 4 Before use to ensure accuracy Purge all air from the fluid lines and dispense valve s AREA 4 FOR BATTERY CAPACIT...

Page 4: ... please contact an authorized service center AREA 4 FOR BATTERY CAPACITY AREA 2 FOR MEASUREMENT UNITS nd button usage Notes It will flashing when battery voltage less than 3 3V OR LAST DISPENSE CYCLE MULATED TOTAL HE NUMBERS FOR G THE CALIBRATION OSING THE UNITS Reset CHOOSING THE UNITS AND SETTING CORRECTION FACTOR RESET RESET SET RESET RESET A Display Mode Start up the Meter by selecting The Met...

Page 5: ...m the value and quit stored 00 00 2see L Lit AUTO see Lit see Gal PT QT Lit Press and hold two times to set the function Press and hold once to set the function AUTO R RESET 5000 3087 L Lit TOTAL AUTO 12 3 lase L Lit User ode If the eter is off ress The value is last amount dis ensed the eter will dis lay automatically Select value Press and hold until the counter turns to zero Reset Batch Total S...

Page 6: ...nking press select YES or No If YES the batch total will be set to button for 10 zero after hold OK STOP seconds NO to cancel to confirm the value and quit the setting mode The setting value will be stored NOTE Independent of the selection carried out the Batch Total supplied is never reset if the dispensing operation has been carried out in AUTO mode 00 00L Lit 0TOTAL yes 1see AUTO C 6 Auto Reset...

Page 7: ...NITS Value ER14250 3 6V 1 35L min 0 5 100bar Data Flow rate Operating Pressure Range 60 C 0 5 Accuracy Battery Max operation temperature 1 2 3 4 5 6 Fig 2 1 Air supply 2 Shut off air valve 3 Oil Pump 4 Shut off oil valve 5 Hose reel 6 Oil control valve Display and button usage Notes It will flashing when battery voltage less than 3 3V AREA 1 FOR LAST DISPENSE CYCLE AREA 3 FOR ACCUMULATED TOTAL Men...

Page 8: ...attery connection Press RESET button Meter does not latch for batching 1 Meter not in AUTO mode 2 Meter not reset after prior batching 3 Low batteries 1 Press AUTO button and program batch size 2 Press RESET button 3 Check for battery icon Replace batteries Press RESET button If the meter has anything wrong please contact an authorized service center We don t recommend customers repair the meter t...

Page 9: ...t com warranty Macnaught Pty Ltd 2017 NOTE This product should be disposed of according to all applicable local and national government environment regulations and guidelines Wearing parts Part No Description Q ty 1 O ring 1 9 O ring 1 13 Battery 1 19 Waterproof protector 2 20 Seal washer 4 Part No Description Q ty 1 O ring 1 2 Meter Holder 1 3 Meter Cover 1 4 Rubber Protector 1 5 Main Circuit Boa...

Reviews: