GENERAL SAFETY REGULATIONS
1. Keep the work area clean and dry. Damp or
wet work areas can result in injury.
2. Keep children away from work area. Do not
allow children to handle this product.
3. Use the right tool for the job. Do not attempt
to force small equipment to do the work of larger
industrial equipment. There are certain applications
for which this equipment was designed. It will
do the job better and more safely at the capacity
for which it was intended. Do not modify this
equipment, and do not use this equipment for
a purpose for which it Was not intended.
4. Check for damaged parts. Before using this
product, carefully check that it will operate
properly and perform its intended function.
Check for damaged parts and any other conditions
that may affect the operation of this product.
Replace damaged or worn parts immediately.
5. Do not overreach. Keep proper footing and
balance at all times to prevent tripping, falling,
back injury, etc.
6. DO NOT use the equipment when tired or under
the influence of drugs, alcohol, or medication.
A moment of inattention while operating this
equipment may result in serious personal injury.
IMPORTANT!
This manual contains important warnings and
information. READ AND KEEP IT FOR REFERENCE.
SAFETY PRECAUTIONS
WARNING!
Precaution before installation:
1. Check if there is any data shown on the display.
2. Check if the trigger can work normally.
3. Check if the oil inlet can rotate well.
INTENDED USE
Oil preset meter can be used to dispense motor
oil. With the pre-selected function, the nozzle
automatically closes the valve and stops dispensing.
WARNING
Read carefully and understand all INSTRUCTIONS
before operating. Failure to follow the safety
rules and other basic safety precautions may
result in serious personal injury. Save these
instructions in a safe place and on hand so that
they can be read when required. Keep these
instructions to assist in future servicing.
AREA 4:
FOR BATTERY CAPACITY
AREA 2:
FOR MEASUREMENT UNITS
Value
ER14250 3.6V
1-35L/min
0.5-100bar
Data
Flow rate
Operating Pressure Range
60°C
±0.5%
Accuracy
Battery
Max operation temperature
1
2
3
4
5
6
Fig. 2
1. Air supply
2. Shut off air valve
3. Oil Pump
4. Shut off oil valve
5. Hose reel
6. Oil control valve
Display and button usage
Notes: It will flashing when
battery voltage less than 3.3V;
AREA 1:
FOR LAST DISPENSE CYCLE
AREA 3:
FOR ACCUMULATED TOTAL
Menu:
MOVING THE NUMBERS FOR
ADJUSTING THE CALIBRATION
AND CHOOSING THE UNITS
Reset:
CHOOSING THE UNITS AND
SETTING CORRECTION FACTOR
AREA 4:
FOR BATTERY CAPACITY
AREA 2:
FOR MEASUREMENT UNITS
Value
ER14250 3.6V
1-35L/min
0.5-100bar
Data
Flow rate
Operating Pressure Range
60°C
±0.5%
Accuracy
Battery
Max operation temperature
1
2
3
4
5
6
Fig. 2
1. Air supply
2. Shut off air valve
3. Oil Pump
4. Shut off oil valve
5. Hose reel
6. Oil control valve
Display and button usage
Notes: It will flashing when
battery voltage less than 3.3V;
AREA 1:
FOR LAST DISPENSE CYCLE
AREA 3:
FOR ACCUMULATED TOTAL
Menu:
MOVING THE NUMBERS FOR
ADJUSTING THE CALIBRATION
AND CHOOSING THE UNITS
Reset:
CHOOSING THE UNITS AND
SETTING CORRECTION FACTOR
AREA 4:
FOR BATTERY CAPACITY
AREA 2:
FOR MEASUREMENT UNITS
Value
ER14250 3.6V
1-35L/min
0.5-100bar
Data
Flow rate
Operating Pressure Range
60°C
±0.5%
Accuracy
Battery
Max operation temperature
1
2
3
4
5
6
Fig. 2
1. Air supply
2. Shut off air valve
3. Oil Pump
4. Shut off oil valve
5. Hose reel
6. Oil control valve
Display and button usage
Notes: It will flashing when
battery voltage less than 3.3V;
AREA 1:
FOR LAST DISPENSE CYCLE
AREA 3:
FOR ACCUMULATED TOTAL
Menu:
MOVING THE NUMBERS FOR
ADJUSTING THE CALIBRATION
AND CHOOSING THE UNITS
Reset:
CHOOSING THE UNITS AND
SETTING CORRECTION FACTOR
FACTORY SETTINGS
•
Each meter is preprogrammed and calibrated at the factory. Each meter is programmed in quarts for
use with motor oil as standard. The meter is shipped in the Manual Mode.
• The factory preset cannot be changed.
TOOL USE
• DO NOT modify or alter the meter.
• DO NOT leave the meter unattended while dispensing.
• Check the meter daily. Worn or damaged parts should be repaired or replaced immediately.
• DO NOT exceed the maximum working pressure level of the lowest rates system component.
• Use only extensions and nozzles that are compatible with this meter.
• Use only fluids and solvents that are compatible with the equipment.
Notice the warnings for fluids and solvents.
• Tighten all fluid connections before operating the meter.
• Comply with all local, state, and federal fire, electrical and safety regulations.
• Use of the product in a manner other than specified in this manual may result in bodily
injury or impaired operation or damage to the meter.
OPERATION
The Digital Meter requires 1 Alkaline cell 9V battery to operate (battery included). For battery
replacement, refer to Section D, Battery Replacement elsewhere in this manual.
TECHNICAL DETAILS
Item No.
L-DPOCG
Flow Range
1-35L/min (0.3-9.2 GPM)
Operating Pressure Range
7-1000 PSI
Operating Temperature
Max. 60°C
Accuracy
±0.5%
Viscosity
8-5000 mPas
5-Digital LCD Display (3/8"H x 3/16"W)
Quart, Pint, Gallon, Liter
Inlet Connection
1/2" BSP (F)
Power Source
1 Alkaline cell 9V
*Tested with DTE-25 motor oil at ambient temperature. Min.-Max. flow range will vary with fluid viscosity.
AUTO
Press to enter and exit the AUTO Mode.
RESET
Press in Manual or AUTO Mode to clear
the previously programmed batch and to
reset the meter.
OK/STOP
Press to confirm the Valve and to stop
the flow through a mechanical override.
AUTO
10
1
0.1
RESET
OK/STOP
Press to enter and exit the AUTO Mode.
1. Keypad buttons