background image

macnaught.com

15     

Lubemate | Digital Preset Oil Control Gun

INSTRUCTION MANUAL

D. Battery replacement

1.   To replace the battery, please open the  

battery cover according to the photo shows.

2.  Pull out the battery electrode.
3.  Remove the used batteries.
4.  Install 1 new 1 Alkaline cell 9V.
5.  Replace the cover again.
The Meter will start automatically as soon  
as the battery pack is fixed, carrying out a  
short SELFTEST:
•  Complete lighting of LCD.
•  Complete stop of LCD.
•  Display of serial number of electronic board.
•  Normal operation mode. 

The replacement of the batteries does not cause any data loss. The customization of the Meter, 
previously set, remains operational.
1.  If the meter does not operate for more than 30 seconds, it will return to sleep mode.
2.  Please pause for more than 30 seconds between reusing AUTO mode.

TROUBLE SHOOTING GUIDE

Problem

Possible Causes

Solutions

Display is 
Blinking

1.  Meter inactive
2.  Batteries low or dead
3.  Program error
4.  Loose battery connection

1.  Press RESET button
2.  Replace batteries / Press RESET button
3.  Remove and reinsert battery pack / Press
  RESET button
4.  Remove battery pack and check battery 

connection / Press RESET button

Meter does  
not latch for 
batching

1.  Meter not in AUTO mode
2.   Meter not reset after
  prior batching
3.  Low batteries

1  Press AUTO button and program batch size
2.  Press RESET button
3.  Check for battery icon / Replace batteries  

/Press RESET button

 
If the meter has anything wrong, please contact an authorized service center. 
We don’t recommend customers repair the meter themselves.

EXPLORED DRAWING & PART LIST

3
2
4

6  1

27

26  28

25

7

22

29

23  19  20

39

8  9

10  12  31

33

30

18

14

46

35

41

36

37

38

21

44 

42

34

40

45

Part 

No.

Description

Q’ty

1

Right cover

1

2*

Meter cover

1

3*

Front label

1

4

Main circuit board

1

6

Cross recessed pan 

tapping screw

4

7

Rod

1

8*

Seat

1

9

Washer

1

10

Spring

1

12

Swivel

1

14

Trigger

1

18

Mandril

1

19

Screw

2

20

Screw

1

Part 

No.

Description

Q’ty

21

Cross recessed pan 

tapping screw

4

22

Battery cover 

components

1

23

Battery cover

1

25

Cam

1

26

O-ring

2

27

Cross recessed pan 

tapping screw

2

28

Washer flat

2

29

left cover

1

30

Flexible spout

1

31*

Filter

1

33

Screw

3

Part 

No.

Description

Q’ty

34

Meter holder

1

35

Body

1

36

Shaft

2

37

Magnetic rod

2

38*

O-ring

1

39

Suction tube

1

40

Shaft

2

41

Rubber protector

1

42

Screw

4

44

Screw

1

45

Spring

1

46

Battery

1

No spare parts available.

MAC0619_Lubemate_InstructionManual_L-DPOCG_D2.indd   15-16

7/8/18   4:43 pm

Summary of Contents for L-DPOCG

Page 1: ...uto shut off gun with totaliser and batch counters 1 2 BSP F inlet swivel Flow range 1 35LPM TECHNICAL SPECIFICATIONS Robust light weight design Ergonomic plastic shell with shockproof rubber the trigger guard prevents accidental operation High accuracy digital oil meter 5 digit easy to read resettable LCD display Flexible extension with auto nozzle Easy access in tight spaces and auto nozzle avoi...

Page 2: ...y Battery Max operation temperature 1 2 3 4 5 6 Fig 2 1 Air supply 2 Shut off air valve 3 Oil Pump 4 Shut off oil valve 5 Hose reel 6 Oil control valve Display and button usage Notes It will flashing when battery voltage less than 3 3V AREA 1 FOR LAST DISPENSE CYCLE AREA 3 FOR ACCUMULATED TOTAL Menu MOVING THE NUMBERS FOR ADJUSTING THE CALIBRATION AND CHOOSING THE UNITS Reset CHOOSING THE UNITS AN...

Page 3: ...PT 1 2 BSP depending on meter model Attach the hose 1 On the opposite end apply sealant to the end of the nozzle 2 Thread the nozzle onto the meter Screw it in tightly with an open ended adjustable wrench 3 Open all dispense position shut off valves start the pump to pressurize system 4 Before use to ensure accuracy Purge all air from the fluid lines and dispense valve s AREA 4 FOR BATTERY CAPACIT...

Page 4: ... please contact an authorized service center AREA 4 FOR BATTERY CAPACITY AREA 2 FOR MEASUREMENT UNITS nd button usage Notes It will flashing when battery voltage less than 3 3V OR LAST DISPENSE CYCLE MULATED TOTAL HE NUMBERS FOR G THE CALIBRATION OSING THE UNITS Reset CHOOSING THE UNITS AND SETTING CORRECTION FACTOR RESET RESET SET RESET RESET A Display Mode Start up the Meter by selecting The Met...

Page 5: ...m the value and quit stored 00 00 2see L Lit AUTO see Lit see Gal PT QT Lit Press and hold two times to set the function Press and hold once to set the function AUTO R RESET 5000 3087 L Lit TOTAL AUTO 12 3 lase L Lit User ode If the eter is off ress The value is last amount dis ensed the eter will dis lay automatically Select value Press and hold until the counter turns to zero Reset Batch Total S...

Page 6: ...nking press select YES or No If YES the batch total will be set to button for 10 zero after hold OK STOP seconds NO to cancel to confirm the value and quit the setting mode The setting value will be stored NOTE Independent of the selection carried out the Batch Total supplied is never reset if the dispensing operation has been carried out in AUTO mode 00 00L Lit 0TOTAL yes 1see AUTO C 6 Auto Reset...

Page 7: ...NITS Value ER14250 3 6V 1 35L min 0 5 100bar Data Flow rate Operating Pressure Range 60 C 0 5 Accuracy Battery Max operation temperature 1 2 3 4 5 6 Fig 2 1 Air supply 2 Shut off air valve 3 Oil Pump 4 Shut off oil valve 5 Hose reel 6 Oil control valve Display and button usage Notes It will flashing when battery voltage less than 3 3V AREA 1 FOR LAST DISPENSE CYCLE AREA 3 FOR ACCUMULATED TOTAL Men...

Page 8: ...attery connection Press RESET button Meter does not latch for batching 1 Meter not in AUTO mode 2 Meter not reset after prior batching 3 Low batteries 1 Press AUTO button and program batch size 2 Press RESET button 3 Check for battery icon Replace batteries Press RESET button If the meter has anything wrong please contact an authorized service center We don t recommend customers repair the meter t...

Page 9: ...t com warranty Macnaught Pty Ltd 2017 NOTE This product should be disposed of according to all applicable local and national government environment regulations and guidelines Wearing parts Part No Description Q ty 1 O ring 1 9 O ring 1 13 Battery 1 19 Waterproof protector 2 20 Seal washer 4 Part No Description Q ty 1 O ring 1 2 Meter Holder 1 3 Meter Cover 1 4 Rubber Protector 1 5 Main Circuit Boa...

Reviews: