Lubemaster OS600 Std
3102 Operating Manual V2020.01
Page
9
of
29
3.1.3
SHUTTING DOWN PRIOR TO RELOCATING
Whilst the Lubemaster remains running:
•
Turn off heater and vacuum switches at the main control panel.
•
Turn off suction valve at equipment oil supply whilst Lubemaster remains running.
•
Disconnect suction hose from plant end and elevate the hose to drain oil into the Lubemaster.
Allow to suck disconnected for no more than 1 minute.
•
Turn off pump at the ‘PUMP’ switch.
•
Turn off the main isolation prior to servicing.
•
Fully service and drain machine components if moving to a different oil grade or type.
•
Allow 10 minutes for the rotor to stop spinning and for the oil to drain from the rotor.
•
Run the pumps for 30 seconds after drain time to empty drained oil from the vacuum chamber.
•
Isolate and disconnect the oil return hose.
•
Hang hoses to drain and service machine according to requirements for next use.