Zhengzhou Linghang Robot Co.,Ltd.
13 / 42
2.3 Optional modules
This model has 4 module mounting interface , can install electrical module ,
bus communication module, Servo motor module, Ultrasonic module, air and
liquid module, to learn more details of modules pls check below link:
https://www.ltautotools.com/products/ltc-0300g-tool-changer.html
3. Installation
The end effector is usually connected to the tool plate through the tool
adapter flange. We can provide standard and customized tool adapter
flanges as required.
All fasteners used to install the tool changer on the robot and tools
shall be tightened to the torque value as indicated. In addition, removable
(blue liquid glue) Loctite 242 anaerobic adhesive shall be used for
fasteners.The pneumatic pipeline and cable are fixed and tied together, and
must be able to move freely during operation.
Warning: before maintaining or repairing the tool changer, be
sure to place the tool on the tool holder or tool station, turn off
all electrical, air, water etc., and the electrical power supply
has been discharged from the circuit according to the customer's specific
safety operation procedures and policies. And confirm that the air pressure
and liquid pressure have been released.
Warning: pneumatic fittings and pipelines must be able to
withstand repeated movements of the application without
failure.
The wiring of electrical and pneumatic lines must minimize the possibility
of over stress, pull-out or kink. Failure to do so may result in critical