7. Function List
7-2
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
5
Setting via
potentiometer
on the keypad
+ I terminal
6
Setting via V1
+ I terminal
7
Setting via
potentiometer
on the keypad
+ V1 terminal
8
Modbus-RTU
Communication
St1
[Multi-Step
frequency
1]
0/400
[Hz]
This parameter sets Multi-
Step frequency 1 during
Multi-step operation.
10.0
O
St2
[Multi-Step
frequency
2]
This parameter sets Multi-
Step frequency 2 during
Multi-step operation.
20.0
O
St3
[Multi-Step
frequency
3]
This parameter sets Multi-
Step frequency 3 during
Multi-step operation.
30.0
O
CUr
[Output
current]
-
This parameter displays
the output current to the
motor.
-
-
rPM
[Motor
RPM]
-
This parameter displays
the number of Motor RPM.
-
-
dCL
[Inverter
DC link
voltage]
-
This parameter displays
DC link voltage inside the
inverter.
-
-
vOL
[User
display
select]
-
This parameter displays
the item selected at H73-
[Monitoring item select].
vOL
-
vOL Output voltage
POr Output power
tOr
Torque
nOn
[Fault
Display]
-
This parameter displays
the types of faults, frequency
and operating status at the
time of the fault
-
-
drC
[Direction
of motor
rotation
select]
F/r
This parameter sets the
direction of motor rotation
when drv - [Drive mode] is
set to either 0 or 1.
F
O
F
Forward
r
Reverse
Summary of Contents for SV004iC5-1F