7. Function List
7-1
7. Function List
* The number of page is for User’s manual uploaded at LSIS website. You can
download the User’s manual which is described detailed function of parameter
from website. (
7.1 Drive Group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
0.0
[Frequency
command]
0/400
[Hz]
This parameter sets the
frequency that the inverter is
commanded to output.
During Stop: Frequency
Command
During Run: Output
Frequency
During Multi-step
operation: Multi-step
frequency 0.
It cannot be set greater
than F21- [Max frequency].
0.0
O
ACC
[Accel
time]
0/6000
[sec]
During Multi-Accel / Decel
operation, this parameter
serves as Accel / Decel time
0.
5.0
O
dEC
[Decel
time]
10.0
O
Drv
[Drive
mode]
(Run/Stop
mode)
0/3
0
Run/Stop via Run/Stop key
on the keypad
1
X
1
Run/Stop
via
control
terminal
FX : Motor
forward run
RX : Motor
reverse run
2
FX : Run/Stop
enable
RX : Reverse
rotation select
3
Operation via
Communication Option
Frq
[Frequency
mode]
0/8
0
Digital
Setting via
Keypad 1
0
X
1
Setting via
Keypad 2
2
Analog
Setting via
potentiometer
on the
keypad(V0)
3
Setting via V1
terminal
4
Setting via I
terminal
Summary of Contents for SV004iC5-1F
Page 8: ......
Page 22: ...3 Wiring 3 6 ...
Page 38: ...5 Programming Keypad 5 14 ...
Page 42: ...6 Basic Operation 6 4 ...
Page 64: ...7 Function List 7 22 ...
Page 74: ...9 Specifications 9 4 ...