Turning on the Power and Checking for Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-10
620J Storage Enclosure Installation and Overview Guide
Service Action
Required (Fault)
ESM canister
Power-fan canister
Drive
On
– When the storage enclosure
LED is on, a component within the
storage enclosure needs attention.
On
– The ESM canister, the power-fan
canister, or the drive needs attention.
Off
– The ESM canister, the power-
fan canister, and the drive are
operating normally.
The drive has an LED, but no symbol.
AC Power
ESM canister
Power-fan canister
On
– AC power is present.
Off
– AC power is not present.
DC Power
Power-fan canister
On
– Regulated DC power from the
power canister and the fan canister is
present.
Off
– Regulated DC power from the
power-fan canister is not present.
Link Service Action
Required (Fault)
ESM canister
On
– The cable is attached and at
least one lane has a link-up status,
but one lane has a link-down status.
Off
– The cable is not attached, the
cable is attached and all lanes have a
link-up status, or the cable is
attached and all lanes have a link-
down status.
Link Up
Two LEDs
above each
expansion
connector
ESM canister
On
– The cable is attached and at
least one lane has a link-up status.
Off
– The cable is not attached, or
the cable is attached and all lanes
have a link-down status.
LED
Symbol
Location
General Behavior
Summary of Contents for 620J
Page 1: ...SGI InfiniteStorage IS2224 Installation and Overview Guide 007 5830 002...
Page 2: ...The information in this document supports the SGI InfiniteStorage 2224 IS2224 storage system...
Page 3: ...620J Storage Enclosure Installation and Overview Guide 46129 00 Rev A...
Page 22: ...Installing the Storage Enclosure 2 12 620J Storage Enclosure Installation and Overview Guide...
Page 46: ...FCC 2 620J Storage Enclosure Installation and Overview Guide...