LSI LASTEM E-Log – User’s manual
19
Press key
once again to display the full name of the measured quantity and the input number
the sensor is connected to; if the measure is calculated, the input number will be replaced by "-"; if
the measure is acquired from the serial port, it’s shown (instead of the input number) the sensor’s
network address (with code “A”), and the number of its channel which the measure is referred to
(with code “C”).
In case the instrument has been programmed with one actuation logic at last, press key
once
again to display the measure’s alarm condition: the note “OK” specifies that the measure hasn’t
caused any alarm condition, at the opposite it’s shown the note “Alarm”.
Use keys
to shift between formats.
4.3.3.
Diagnostic information
Some diagnostic windows are used to display information about the operation of the instrument and
the statistics. Diagnostic window type 1:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
D
T
d
d
/
m
m
/
y
y
H
h
:
m
m
:
s
s
E
r
r
e
e
e
e
e
e
e
e
M
e
m
m
m
m
m
k
B
W
W
w
w
w
w
w
M
s
r
A
a
a
S
s
s
C
c
c
where:
dd/mm/yy hh:mm:ss: current date/time of the system;
eeee…:
numeric code, expressed in hexadecimal number, which corresponds
to the 32 bits of the error window of the system; in order to decode
this error, go to §6.3;
mmmm…:
data memory capacity in kByte;
wwww…:
hexadecimal number that expresses the value of the position writing
in the elaborated data memory; the starting value of this position
equals to 200, whereas 128 kB of memory are used for the
configuration information of the instrument; when using a 2 MB
memory, this value is expanded to 1FFF; the unitary increment of
this value indicates a 256 byte consumption; (*)
aa:
number of measures acquired by the inputs of the instrument;
ss:
number of acquired measures from serial port;
cc:
number of calculated measures.
(*) Since the 2.07 version of E-Log, in this position of the window, the percentage of free memory
is displayed; E-Log storages the data in a circular mode and then the memory is virtually endless.
The calculation is based on the availability of total memory space dedicated to data processed
compared to the value transferred to PC through serial line 1; transfer operations from serial port 2
doesn’t change this value; if the instrument indicates the percentage of zero, it means that the
circular storage alghorithm has stored the new data and has cancelled the oldest data.
By pressing the arrow
you can see the old camp which is the number in exadecimal notation
that expresses the value of the position in writing in the memory of the elaborated data (with a
starting value which is equal to 0).
Summary of Contents for E-Log
Page 1: ...Cod INSTUM_00351_en E Log User s manual Updated on 09 18 2017...
Page 15: ...LSI LASTEM E Log User s manual 15...
Page 60: ...LSI LASTEM E Log User s manual 60 6 6 Mask of terminal board...
Page 61: ...LSI LASTEM E Log User s manual 61 6 7 Connection cables...
Page 62: ...LSI LASTEM E Log User s manual 62 6 8 Declaration of Conformity...