30
ACE M2
LCD display faulty
Solution
:
1. Turn off power supply
2. Repower the motor, observe if normal or not
3. If not, remove computer and fixed PCB. Check for damage
4. If no damage clean the PCB gold finger position and retest
LCD displaying but
with dysfunction
Solution
:
A. Turn off power supply and repower the motor
B. Change the computer.
backlight is not bright
Solution
:
A. Turn off the power supply and repower the motor.
B. Start the computer, check if all wires are connected well. Check for
backlight damage
C. Change the computer
A button is not
functioning
Solution
:
A. If only one key is not working, open the computer and check the button
for damage
B. Replace the computer
A. If most keys do not work, restart the treadmill
B. Replace the computer
Pulse function is
unresponsive
Solution
:
A. Wash your hands, test again
B. Check for damage to the pulse sensor cables as well as the connection
terminal
C. Change PCB or computer