Power Point
User Manual
Page 5
Outputs
PWP12/10A
12 x 3-pin 10 Amp
Australian sockets
PWP12/16A/32
12 x 3-pin 20 Amp
Australian sockets.
32A MCB (Main Circuit
Breaker)
PWP6/25A
6 paired 3-pin
20Amp/15Amp
Australian sockets
PWP12/10T
12Ch x 10A
Hardwired terminals
PWP12/16A/40
12 x 3-pin 20 Amp
Australian sockets.
40A MCB (Main Circuit
Breaker)
PWP6/25T
6Ch x 25A
Hardwired terminals
PWP12/10W
2 x 16-pin Wieland
sockets
PWP12/10X.
2 x 19-pin Socapex
sockets
PWP12/10P
12 x PowerCON
sockets
5.1
Wieland Pinouts
Connector 1
Function
Connector 2
Function
Pin 1
Chan 1 Active
Pin 1
Chan 7 Active
Pin 2
Chan 2 Active
Pin 2
Chan 8 Active
Pin 3
Chan 3 Active
Pin 3
Chan 9 Active
Pin 4
Chan 4 Active
Pin 4
Chan 10 Active
Pin 5
Chan 5 Active
Pin 5
Chan 11 Active
Pin 6
Chan 6 Active
Pin 6
Chan 12 Active
Pin 7
Not used
Pin 7
Not used
Pin 8
Not used
Pin 8
Not used
Pin 9
Chan 1 Neutral
Pin 9
Chan 7 Neutral
Pin 10
Chan 2 Neutral
Pin 10
Chan 8 Neutral
Pin 11
Chan 3 Neutral
Pin 11
Chan 9 Neutral
Pin 12
Chan 4 Neutral
Pin 12
Chan 10 Neutral
Pin 13
Chan 5 Neutral
Pin 13
Chan 11 Neutral
Pin 14
Chan 6 Neutral
Pin 14
Chan 12 Neutral
Pin 15
Not used
Pin 15
Not used
Pin 16
Not used
Pin 16
Not used
Note:
Earth connection is via the clips on the side of the socket insert.
Note:
This is the recommended wiring scheme for Harting/Wieland connectors. An alternative
wiring scheme exists for these connectors and Power Point units can be wired to the alternative