background image

Power Point 

 

User Manual 

 

Page 2 

 

Disclaimer 

LSC Control Systems Pty Ltd has a corporate policy of continuous improvement, covering areas 
such  as  product  design  and  documentation.  To  achieve  this  goal,  we  undertake  to  release 
software updates for all products on a regular basis. In light of this policy, some detail contained 
in this manual may not match the exact operation of your product. Information contained in this 
manual is subject to change without notice. 
 
In any event, LSC Control Systems Pty Ltd cannot be held liable for any direct, indirect, special, 
incidental, or consequential damages or loss whatsoever (including, without limitation, damages 
for  loss of profits, business interruption, or  other pecuniary  loss)  arising out of the use or the 
inability to use this product for its intended purpose as expressed by the manufacturer and in 
conjunction with this manual. 
 
Servicing of this product is recommended to be carried out by LSC Control Systems Pty Ltd or 
its authorised service agents. No liability will be accepted whatsoever for any loss or damage 
caused by service, maintenance or repair by unauthorised personnel.  
In addition, servicing by unauthorised personnel may void your warranty. 
 
LSC Control Systems’ products must only be used for the purpose for which they were intended. 
 
Whilst  every  care  is  taken  in  the  preparation  of  this  manual,  LSC  Control  Systems  takes  no 
responsibility for any errors or omissions. 
 

Copyright Notices 

“LSC Control Systems” is a registered trademark. 
 
lsccontrol.com.au is owned and operated by LSC Control Systems Pty Ltd. 
 
All Trademarks referred to in this manual are the registered names of their respective owners. 
 
All rights reserved. 
 

 

 

 

 

 

 

Contact Details 

LSC Control Systems Pty Ltd 
 
ABN 21 090 801 675 
 
65-67 Discovery Road 
Dandenong South, Victoria 3175 Australia 
Tel: +61 3 9702 8000 
 
email: 

[email protected]

 

web:   

www.lsccontrol.com.au

 

 

Summary of Contents for Power Point

Page 1: ...Power Point Power Distribution System User Manual LSC Control Systems 61 3 9702 8000 info lsccontrol com au www lsccontrol com au Version 1 2 August 2021 ...

Page 2: ...nd in conjunction with this manual Servicing of this product is recommended to be carried out by LSC Control Systems Pty Ltd or its authorised service agents No liability will be accepted whatsoever for any loss or damage caused by service maintenance or repair by unauthorised personnel In addition servicing by unauthorised personnel may void your warranty LSC Control Systems products must only be...

Page 3: ...ting Up and Connecting 3 3 1 Safety 3 3 2 Unpacking 3 3 3 Mounting 3 3 4 Connections 3 3 4 1 Input Power Supply 3 3 4 2 Outputs and Phasing 3 4 Specifications and Output Options 3 4 1 Wieland Pinouts 5 4 2 Socapex Pinouts 6 5 Troubleshooting 3 5 1 Maintenance 3 5 2 Tripped Breakers 3 6 Compliance Statements 6 ...

Page 4: ... Three neon indicators show state of input phase power Easily visible from a distance Twelve 10A twelve 16A or six 25A output circuits Residual Current circuit Breaker with Overcurrent protection RCBO devices for each output circuit are used to combine protection against current overload and short circuits and protection against earth leakage currents Essentially they protect connected loads and p...

Page 5: ... OFF position before connecting or disconnecting any loads The individual outputs are fed from the following input power phases This input phase numbering is also shown on the front panel below each output circuit breaker Input Phase Output Input Phase Output 1 1 1 7 2 2 2 8 3 3 3 9 1 4 1 10 2 5 2 11 3 6 3 12 4 Troubleshooting Warning No user controls or user serviceable parts are located inside t...

Page 6: ... with rear panel mounted 5 cage clamp style terminals Supplied with 1 2m long H07 rubber 5 core x 6mm cable with 32A 5 pin 3 phase plug fitted export models supplied with no plug Supplied with 1 2m long H07 rubber 5 core x 10mm cable no connector supplied export models supplied with no plug PWP12 16 32A model supplied with 3 phase 1 2m H07 5 core x 6mm rubber cable fitted with 32A 3 phase plug PWP...

Page 7: ... 8 Active Pin 3 Chan 3 Active Pin 3 Chan 9 Active Pin 4 Chan 4 Active Pin 4 Chan 10 Active Pin 5 Chan 5 Active Pin 5 Chan 11 Active Pin 6 Chan 6 Active Pin 6 Chan 12 Active Pin 7 Not used Pin 7 Not used Pin 8 Not used Pin 8 Not used Pin 9 Chan 1 Neutral Pin 9 Chan 7 Neutral Pin 10 Chan 2 Neutral Pin 10 Chan 8 Neutral Pin 11 Chan 3 Neutral Pin 11 Chan 9 Neutral Pin 12 Chan 4 Neutral Pin 12 Chan 10 ...

Page 8: ...tral Pin 7 Chan 4 Active Pin 7 Chan 10 Active Pin 8 Chan 4 Neutral Pin 8 Chan 10 Neutral Pin 9 Chan 5 Active Pin 9 Chan 11 Active Pin 10 Chan 5 Neutral Pin 10 Chan 11 Neutral Pin 11 Chan 6 Active Pin 11 Chan 12 Active Pin 12 Chan 6 Neutral Pin 12 Chan 12 Neutral Pin 13 Earth Pin 13 Earth Pin 14 Earth Pin 14 Earth Pin 15 Earth Pin 15 Earth Pin 16 Earth Pin 16 Earth Pin 17 Earth Pin 17 Earth Pin 18 ...

Reviews: