(4) Replacing Air cleaner element
(Dry type)
Remove the cover and pull the primary element
straight out, ensuring the safety filter element
remains in place.
Clean the inside of the air cleaner housing using
a clean damp cloth, taking care not to damage
the safety element.
Check if there is damage inside filter element by
using a light. If finding tiny crack or small holes
in the filter element or the gasket is damaged,
change it with a new one.
(5) Tension adjustment of Fan belt
If the tension of fan belt exceeds the standard
value, loosen the bolt and adjust the tension.
- Belt tension : crank axle pulley ~ alternator
pulley
- Standard : approx. 10~12mm(0.39~0.47in)
(if pressed by 98N (22.04 lb))
Adjusting plate
Bolt
Insert the filter element by pushing it deeply into the filter housing.
Remove the dust of the evacuator valve and clean the inside of the cover.
Assemble the cover with the evacuator valve placed downward.
▶
Do not start the engine or close the hood if the filter element is not assembled..
Notice
5
5
5
5
- 17
(if pressed by 98N (22.04 lb))
When adjusting the tension,
1. Loosen 2 bolts of alternator and insert the
bar between crank case and pull the bar to apply
tension to the belt.
2. With proper tension, tighten the bolts attached to
the adjusting plate of alternator.
3. If the tension of belt becomes standard value,
tighten the bolt which whole the alternator
Generator
pulley
Cooling
water
pump
pulley
Crank axle pulley