Chapter 4 - Operation
4-17
Parameter Name
Code
Description
Accel/Decel time
setting for each
step
I/O-50 ~ 63
Accel/Decel time for each step setting
Jog freq.
I/O-30
jog freq for jog operation setting
Speed-
X
Speed-
H
Speed-
M
Speed-
L
JOG Speed Command
Parameter
value
0
0
0
0
0
Speed 0
DRV-00
0
X
X
X
1
Jog freq.
I/O-20
0
0
0
1
0
Speed
–1
DRV-05
0
0
1
0
0
Speed
–2
DRV-06
..
..
..
..
..
..
..
..
..
..
..
..
..
..
1
1
0
1
0
Speed
–13
I/O-40
1
1
1
0
0
Speed
–14
I/O-41
1
1
1
1
0
Speed
–15
I/O-42
6) 2
nd
motor operation
2
nd
function setting is required to run the two motors by one inverter by exchange.
If the terminal defined for 2
nd
function signal input is turned ON, 2
nd
motor operation
is valid.
Parameter Name
Code
Description
Programmable
Digital Input
terminals setting
I/O-20 ~27
2
nd
motor operation is available with
Programmable Digital Input terminals M1
~ M8 set to 7 {2
nd
Func}.
Parameter setting
for 2
nd
motor
operation
APP-20 ~ APP-29
Setting parameters necessary to operate
2
nd
motor such as base freq., Accel/Decl
time, Stall.
7) Energy-saving operation
FU1-51 [Energy Save Level] tunes the inverter output voltage to minimize the
inverter output voltage during constant speed operation. Appropriate for energy-
saving applications such as fan, pump and HVAC.