Chapter 7 Programming
7-9
7.2.1 Count mode setting
Example explaing how to set Ring Count Min. and Max. As for setting method by ‘I/O Parameter’, refer to Chapter 4.
1. Setting content
Parameter
CH0
CH1
Count mode
1: Ring counter
1: Ring counter
Ring counter min.
0
0
Ring counter max.
100000
100000
2. Program
(1) Scan program of XGK series
(2) Scan program of XGI/XGR series