Protect Switch 400V motors
Version:
3.0 | 14.02.2021
instruction manual | 1162723-00000
page
8
from
29
4.3
Electrical properties
DESIGNATION
VALUE
UNIT
Line protection back-up fuse
16
A
Input voltage Rated value
400 / 480
V AC
Input current Rated value
2,4
A
Rated frequency
50 / 60 (+/- 10%)
Hz
Surge voltage Rated value
2,5
kV
control voltage
24 (+/-20%)
V DC
Auxiliary current
85
mA
load voltage
42 - 550
V AC
load current
0.18 - 2.4 adjustable (see table)
A
starting current
max. 8x In (rated current)
usage category
2,4A with AC-51 and AC-53a
dissipation
4
W
switching frequency
<= 2
Hz
current monitoring
NO
EXECUTION
ELR
Switching characteristics
Right / Left
Tripping class according to
IEC 60947
Class 10
Automatic reset (ready to
start)
20 minutes after overload
Electromagnetic
compatibility
in accordance with EN 61000-4-2/3/4/5/6/8/11/29/39, EN 55011
Radiated, EN 55011 Conducted
communications system
AS-i Safety at Work
AS-i voltage
18 - 31,6
V DC
AS-i specification
3.0
Safety Integrity Level
according to IEC 61508
SIL3
Performance Level
according to ISO 13849
PLe
Category according to ISO
13849
3
MTTF at 40°C
39,3
year