5-9 DSC Test Reply (TEST REPLY)
You can respond to incoming DSC TEST calls with an automatic response or with a manual
response.
•
MANUAL
manual response is required, press ENT to confirm or press EXIT to cancel.
•
AUTO
automatically replies after a 10 second delay with an ACK to any incoming
DSC TEST call.
DSC SETUP
LL REPLY
▲
AUTO SWITC
►
TEST REPLY
TIMEOUT
TEST REPLY
►
AUTO
MANUAL
5-10 Set the inactivity timer (TIMEOUT)
You can set the inactivity timer with the following options:
•
AUTOMATED
you can set the inactivity timer to automatically timeout after a
period of inactivity for the following two categories: NON-DISTRESS or
DISTRESS.
Timeout options are:
DISTRESS: NO TIMEOUT; 5 MINS; 10 MINS (default is NO TIMEOUT)
NON-DISTR: NO TIMEOUT; 10 MINS; 15 MINS (default is 15 MINS)
•
NON AUTO
you can set the inactivity timer to exit any non-automated procedure
activity.
Timeout options are:
NO TIMEOUT; 10 MINS; 15 MINS (default is 10 MINS)
Note:
If NO TIMEOUT is selected, then you must press the EXIT key to exit the procedure.
Example:
to set a 10 minute TIMEOUT for non-automated functions:
1.
Select TIMEOUT, then select NON AUTO
2.
Select desired timeout period: NO TIMEOUT, 10 MINS or 15 MINS
NON AUTO
NO TIMEOUT
►
10 MINS
15 MINS
TIMEOUT
►
AUTOMATED
NON AUTO
DSC SETUP
LL REPLY
▲
AUTO SWITC
TEST REPLY
►
TIMEOUT
In this example, 10 MINS has been selected, meaning the radio will exit any non-automated
procedure after a period of 10 minutes of non-activity.