![LOWES EUK60BNK10LRS Manual Download Page 11](http://html1.mh-extra.com/html/lowes-0/euk60bnk10lrs/euk60bnk10lrs_manual_1942654011.webp)
11
Wrap electrical tape (not included) around each
individual wire connector (CC) down to the wire.
WARNING
: Make sure no bare wire or wire
strands are visible after making connections. Place
GREEN and WHITE connections on opposite side of
the outlet box from the BLACK and BLUE (if
applicable) connections.
2.
CC
2
CC
CC
WARNING:
To reduce the risk of fire, electrical shock or personal injury, wire connectors
provided with this fan are designed to accept only one 12-gauge house wire and two lead wires from
the fan. If your house wire is larger than 12-gauge or there is more than one house wire to connect to
the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.
CAUTION:
Be sure outlet box is properly grounded and that a ground (green or bare) wire is
present.
WARNING:
If house wires are different colors than referred to in the following steps, stop
immediately. A professional electrician is recommended to determine wiring.
WARNING:
Using a full range dimmer switch (not included) to control fan speed will cause a loud
humming noise from fan. To reduce the risk of fire or electrical shock, do NOT use a full range
dimmer switch to control fan speed.
WIRING
NOTE:
BLACK wire is hot power for fan. WHITE
wire is common for fan and light kit.
BARE
/
GREEN wire is ground.
1.
IMPORTANT:
For each wire connection below, use
one of the wire connectors (CC), making sure to
screw wire connector (CC) on in a clockwise
direction.]
Connect BLACK wire from fan to BLACK wire from
ceiling. Connect WHITE wire from fan to WHITE
wire from ceiling. Connect all GROUND
(GREEN)
wires together from fan (on mounting bracket) to
BARE
/
GREEN wire from ceiling.
1
BLACK
WHITE
GROUND/GREEN (BARE)
WHITE
WHITE
120 V
FROM CEILING
FAN
GREEN
BLACK
GREEN
Hardware Used
Wire Connector
x 3
CC