Read  carefully  before  proceeding  with  product assembly and  commis-
sioning operations. For the pump, refer to its manual.

The GENYO electronic controller commands the starting and stopping of
single-phase electric water pumps whenever a tap or valve connected to
the installation is opened or closed, respectively.
When the pump is started, it keeps running as long as any connected tap
remains open, supplying the network with the required flow at the related
pressure.

• Inlet connection

: R 1 

• Outlet connection

: R 1 

• Non-water hammer check valve.
• Dry-running protection system.
• Pressure gauge.
• Manual start button (RESET).
• AUTORESET function for automatic start after a failure.
• Power supply LED (POWER).
• Pump switch-on LED (ON).
• Safety system activation LED (FAILURE).

• Power supply voltage: 1~ 220-240V (Version 1~115-125V upon request)  
• Maximum current

: 16 A

• Max pump power

: 2200 W (3 HP)  at 1~ 220-240V

1100 W (1.5 HP)  at 1~ 115-125V

• Frequency

: 50/60 Hz

• Protection class

: IP 65 (*)

• Ambient temperature

: 0 /+60° C (*)  

• Liquid temperature

: 0 /+60° C (*)

• Max flow rate

: 10,000 l/h

• Adjustable starting pressure

: 1.5 - 3 bar

• Max operating pressure

: 10 bar

(*) Provided the cable glands and screws in cover 

1

have been suitably tigh-

tened (for the cross section of the cable, see 5.2 Electrical Connection)

Handle with care.Falls and collisions can damage the product.

Before proceeding with installation, make sure GENYO shows no visible
signs of damage, otherwise contact the reseller.

GENYO must be assembled and installed by personnel qualified in accor-
dance with the regulations locally in force.

5.1 Water Connection (Fig.1)
GENYO  must  always  be  installed  in  the  vertical  position,  with  the
arrows  pointing  upward,  connecting  the  R1  threaded  inlet  to  the
pump’s outlet and the R1 threaded outlet to the network.

Use  flexible  pipes  for  connection  to  the  water  network,  protecting  the
appliance from any bending loads and vibrations, a ball tap to isolate the
pumpset from the network, a tap (A) on the same level as GENYO and a
foot valve (Fig.1).

Before starting up the unit, fill the suction circuit with water
as specified in the pump’s manual.

WARNING. 

The  maximum  operating  height  between  the  pump  and

the highest point in the system will depend on the start pressure. The
maximum  pressure  of  the  pump  (closing  contact  pressure)  must
exceed a value that depends on the start pressure. Both these limits
are specified in the table below.

START

MAX. OPERATING

MAX. PUMP PRESSURE

PRESSURE

HEIGHT

GREATER THAN

1,5 bar

10 m

3 bar

2,0 bar

15 m

3,5 bar

2,5 bar

20 m

4 bar

3,0 bar

25 m

4,5 bar

5.2 Electrical Connection (Fig.2)

The connections must be made by qualified personnel. Install
a  high-sensitivity  differential  switch  (0.03  A)  for  protection
against lethal electric shock.
First of all, connect the ground conductor. 

Make  sure  that  the  mains  voltage  corresponds  to  the  rated  voltage.
Remove  the  cover 

1

from  the  electronic  board  and  make  the  electrical

connection  according  to  the  instructions  shown  on  the  plate 

2

.  GENYO

can also be used with a single-phase pump with electrical input greater
than  16  A,  or  a  three-phase  pump,  using  an  auxiliary  remote  control
switch (230 V coil) or control panel. In this case the electrical connections
must be made as shown in the diagram, Fig.3.

WARNING. 

Power  supply  voltages  other  than  those  specified  or

improper connections can damage the electronic circuit irreparably.

H07RN - F 3G1,5  type cables (Ø 9 ÷ 12 mm) must be used in
order to ensure IP 65 protection.

1)  Check that the pump is primed properly, then partially open a tap in  the

user circuit.

2)  Connect GENYO to the power mains; the power LED will light up (POWER).
3)    The  pump  will  start  up  automatically  and  within  20  to  25  seconds  the

system should reach approximately the maximum pressure delivered by
the  pump.  While  the  pump  is  running,  the  corresponding  LED  (ON)  will
remain illuminated.

4)  Close the tap mentioned under point 1). After  10-12 seconds the pump

will stop running, but the power supply LED (POWER) will remain lit. Any
malfunctions occurring after these operations will be caused by improper
priming or failure to prime.

GENYO  is  factory  set  to  start  with  a  minimum  pressure  of  1.5  bar.  This
pressure can be increased up to 2.5 bar by rotating the screw found at
the top of the device, which can be seen by detaching the middle part of
the warning label (see Fig. 4).
For this purpose:
1) Read the pressure indicated by the gauge when the pump is started.
2) Disconnect the power supply.
3) Open a tap to discharge the pressure.
4) Adjust the screw at the top to increase (or decrease) the start pressure.
5) Supply power to GENYO;  if you are not satisfied with the adjustment,

repeat  the  operations  described  above  until  you  obtain  the  desired
pressure value.

N.B. The maximum pressure of the pump (closing contact pressure)
and the minimum start pressure must comply with the values shown
in the table under paragraph 5.1 otherwise GENYO will go into FAI-
LURE mode.

If the device goes into failure mode, this function will execute a series of
automatic starts to attempt to restore operation without any manual inter-
vention via the RESET button.
The system operates as follows: The appliance is in failure mode due to
water failure, for example; after 5 minutes in this condition the system will
do  a  25-second  RESET,  attempting  to  prime  the  pump.  If  the  system  is
able to prime the pump, the failure will disappear and the pump will be
ready to operate without any problems. However, if the failure persists, the
system will do another RESET after 30  minutes, and will continue in this
manner systematically every 30 minutes for 24 hours. If the failure still per-
sists after all these attempts, the system will remain in this condition until
the problem has been resolved by manual intervention.

1.- THE PUMP DOES NOT STOP:

A) Water  loss  exceeding  3  l/min.  Make  sure  that  all  the  taps  along  the

pipeline are closed.

B) Electronic board malfunction: replace the electronic board.
C) The electrical connection is incorrect: refer to the instructions in Fig.2.

2.- THE PUMP DOES NOT START:

A) The pump is not primed; the protection against dry running has step-

ped  in  and  the  FAILURE  LED  is  on:  prime  the  water  pipe,  drain  the
system  water  by  opening  tap  (A)  on  the  same  level  as  GENYO  to
decrease the pressure of the water column over it (Fig.1), and check
by pressing the manual start button (RESET).

B) The pump has shut down: the safety system has stepped in and the

FAILURE LED  is on. If you press the manual start button (RESET) the
LED (ON) lights up; if the pump does not start call customer service.

C) Electronic board malfunction: disconnect the pump from the electrical

mains and re-connect it; the pump should start, if it does not replace
the electronic board.

D) No power supply: check the electrical connections, the POWER LED

must be illuminated.

E) The  pump  delivers  insufficient  pressure,  the  safety  system  has  step-

ped  in  and  the  corresponding  LED  (FAILURE)  is  illuminated:  make
sure that the pump pressure corresponds to the pressure value speci-
fied in the relevant table in the section titled “Water Connection”.

F) Air is entering the pump through the suction side: the pressure is much

below normal, with constant fluctuations. The safety system will step in
and stop the pump, the FAILURE LED will light up. Check the seal and
connections in the suction pipe.

3.- THE PUMP KEEPS STARTING AND STOPPING:

There is a small leak in the delivery pipeline: check for any dripping taps
or running toilets.

Lowara srl., with headquarters in Montecchio Maggiore - Vicenza - Italy,
hereby declares that the following product: 

GENYO 16A / R15 - 30  in the

versions with (out) 0.5 m cable and 1.5 m power cable and plug 

com-

plies with the provisions of the following European Directives and with the
regulations transposing them into national law:
• Low Voltage Directive 2006/95/EC (Year of first use of the mark: 2006)
• Electromagnetic Compatibility Directive 2004/108/EC and subsequent

amendments and complies with the following technical standards:

• EN 60730-2-6, EN 61000-6-2:2005, EN 61000-6-3:2001
Montecchio Maggiore, 9.3.2010 
Amedeo Valente
(DIRECTOR ENGINEERING AND R&D)

!

!

en

1. APPLICATIONS AND OPERATION

2. CONSTRUCTION CHARACTERISTICS 

3. SPECIFICATIONS

4. HANDLING AND PRELIMINARY INSPECTION

5. INSTALLATION

6. START UP

10. EC DECLARATION OF CONFORMITY

7. STARTING PRESSURE ADJUSTMENT (P. Start)

8. AUTOMATIC RESET FUNCTION

9. TROUBLESHOOTING

Summary of Contents for Genyo 16A/R15-30

Page 1: ...dr rende installation og brug Sikkerhed Overensstemmelseserkl ring Instruktioner f r installation och anv ndning S kerhet F rs kran om verensst mmelse Instruksjoner for installasjon og bruk Sikkerhet...

Page 2: ......

Page 3: ...GE DE GENYO 16A fr GENYO 16A BELASTNINGSF RLUST sv GEF LLVERLUSTE GENYO 16A de GENYO 16A KUORMITUSH VI T fi P RDIDAS DE CARGA DE GENYO 16A es STRATY CI NIENIA GENYO 16A pl PERDA DE CARGA GENYO 16A pt...

Page 4: ...omalia nel funzionamento dopo tali operazioni provocata dal man cato adescamento della pompa GENYO pretarato per avviarsi con una pressione minima di 1 5 bar Questa pressione pu essere aumentata fino...

Page 5: ...GENYO is factory set to start with a minimum pressure of 1 5 bar This pressure can be increased up to 2 5 bar by rotating the screw found at the top of the device which can be seen by detaching the m...

Page 6: ...ions est provoqu e par le non amor age de la pompe GENYO est pr r gl pour d marrer une pression minimum de 1 5 bar Cette pression peut tre augment e jusqu 2 5 bar en tournant la vis situ e dans la par...

Page 7: ...gen nach diesem Vorgehen sind auf das fehlende Anf llen der Pumpe zur ckzuf hren GENYO wird werkseitig so eingestellt dass das Ger t mit einem Mindestdruck von 1 5 bar angelassen wird Dieser Druck kan...

Page 8: ...despu s de estas operaciones depende de la falta de cebado de la bomba GENYO est precalibrado para ponerse en marcha con una presi n m ni ma de 1 5 bar Esta presi n se puede aumentar hasta 2 5 bar gi...

Page 9: ...o causadas por falhas na ferragem da bomba ARRANQUE P Start GENYO est pr ajustado para arrancar com uma press o m nima de 1 5 bar Esta press o pode ser aumentada at 2 5 bar rodando o parafuso posto n...

Page 10: ...C 2 2 B Led FAILURE RESET Led ON C D Led POWER E Led FAILURE F Led FAILURE 3 WC Lowara srl Montecchio Maggiore Vicenza I 0 5 m 5 m 0 CE GENYO 6A R 5 30 7 P Start 8 RESET 9 2 6 3 4 5 IP 65 H07RN F 3G...

Page 11: ...erking na deze handelingen worden veroorzaakt doordat de aanzuiging van de pomp niet plaatsgevonden heeft 7 De GENYO is van tevoren ingesteld om te starten op een minimum druk van 1 5 bar Deze druk ka...

Page 12: ...e indgreb skyldes manglende sp dning af pumpen INDSTILLING AF GENYO er kalibreret til start ved et min tryk p 1 5 bar Dette tryk kan ges til maks 2 5 bar ved at dreje den verste skrue Skruen kan ses e...

Page 13: ...justert p forh nd for starte med et trykk p minimum 1 5 bar Dette trykket kan kes til opptil 2 5 bar ved dreie p skruen som befin ner seg i den vre delen synlig etter at den midtre delen til varseleti...

Page 14: ...INST LLNING AV STARTTRYCK P Start GENYO har st llts in p ett starttryck p 1 5 bar Detta tryck kan kas till max 2 5 bar genom att du vrider p skruven p pumpens vre del Skruven syns n r du tar bort den...

Page 15: ...ran merkkivalo POWER j palamaan N iden toimenpiteiden j lkeen ilmaantuvat toimintah iri t ovat seurausta pumpun puutteellisesta k ynnistyst yt st GENYO on esikalibroitu k ynnistym n 1 5 bar minimipain...

Page 16: ...zasilania POWER Ka da anomalia w funkcjono waniu po takich czynno ciach jest spowodowana brakiem zalania pompy GENYO jest wst pnie wykalibrowany do rozruchu z minimalnym ci nieniem 1 5 bar To ci nieni...

Page 17: ...minimum bas n ile al t r labilmek i in nceden ayarlanm t r Uyar etiketinin orta k sm kar ld ktan sonra g r lebilen st k s mda yer alan vida d nd r lerek bu bas n 2 5 bar de erine kadar y kseltilebili...

Page 18: ...ar 25 m 4 5 bar CE 5 2 2 0 03 A 1 2 GENYO 16 A 230 V 3 IP 65 H07RN F 3G1 5 9 12 mm GENYO R1 R1 A GENYO FAILURE A GENYO RESET 2006 95 EC 2006 2004 108 EC 2010 03 09 EN 60730 2 6 EN 61000 6 2 2005 EN 61...

Page 19: ...3 0 25 4 5 2 GENYO POWER 3 20 25 ON 4 0 2 POWER GENYO 5 2 5 4 2 3 4 5 GENYO 5 GENYO RESET 5 25 30 30 24 A 3 B C 2 2 B ON C D E F 3 Lowara srl Montecchio Maggiore Vicenza Italia GENYO 6A 5 0 R 5 30 0 5...

Page 20: ...iguse teha muudatusi eelnevalt ette teatamata lv Lowara patur ties bas veikt izmai as bez iepriek ja br din juma lt Lowara pasilieka teis atlikti pakeitimus be i ankstinio sp jimo pl Lowara zastrzega...

Reviews: