11
Factory settings chart (the electric pumps may not all be available for installation on the
GTKS units).
Level kit 230V code 109890700
Probe sensitivity adjustment:
The sensitivity is adjusted by operating the trimmer (see figure n. 2) located on the SLD module.
By rotating the trimmer clockwise, the sensitivity of the probes increases.
11. Shutdown
Unit shutdown takes place as follows:
When the water demand decreases, the pressure in the delivery manifold increases. As the
pressure increases, the last pump to be started slows down until it stops. The same happens for all
the pumps in the unit (inverted order of the starting sequence).
12. Visual
Signalling
Devices
On the adhesive plate attached to the radiator there are three LED’s having the following functions:
Steady green light
Power Indicates that the TKS system is powered
Steady yellow light
Run
Indicates that the first pump to be started is running
Flashing yellow light
Run
Indicates that the second pump to be started is
running
Flashing red light
Alarm Indicates that an alarm has triggered
If an alarm is triggered, the red light will flash more or less rapidly depending on what has caused
the system to shut down. Except for lack of water on the suction side, in all other cases the system
will verify every 20 seconds whether the cause of the failure still persists. If three consecutive
alarms occur, the system will shut down definitively (See alarm section). In the event of a
shutdown, system operation can be restored by disconnecting the power supply for at least one
minute or until all the indicator lights go off. The alarm triggered by lack of water on the suction side
has no limits as regards the number of alarms.
WARNING
109898360
TKS/
Kpa
bar
/BG7
300
3,0
/BG11
350
3,5
/CEA80/5
250
2,5
/CEA120/5
200
2,0
/3SV08..007T
500
5,0
/3SV12..011T
700
7,0
/5SV05..007T
300
3,0
/5SV058..011T
450
4,5
/10SV02...007T
200
2,0
/10SV03...011T
250
2,5
/3VM05P07T
400
4,0
/3VM07P11T
600
6,0
/5VM05P11T
400
4,0
/10VM02P11T
200
2,0
/3HM05S04T
250
2,5
/3HM06P11T
450
4,5
/5HM05P11T
350
3,5
/10HM02P11T
200
2,0
/1HM16S07T
700
7,0
/1HM22S11T
950
9,5
/3HM08S07T
400
4,0
/3HM13S11T
650
6,5
/5HM08S11T
400
4,0
TKS_TABELLATARATURE_C
Pressione/Pressure/Pression/Pressão
Drunckwertes/
ƽƹƻDŽƾdžǁƾ
/Presión/Druk
Summary of Contents for 10HM02P11T
Page 4: ......
Page 9: ......
Page 15: ......
Page 18: ......
Page 23: ......
Page 29: ......
Page 32: ......
Page 37: ......
Page 43: ......
Page 46: ......
Page 51: ......
Page 57: ......
Page 71: ...71...
Page 72: ...72 P E NL NOTES NOTAS AANTEKENINGEN...
Page 73: ...P E NL NOTES NOTAS AANTEKENINGEN...
Page 74: ...P E NL NOTES NOTAS AANTEKENINGEN...