35
12. Fuse
If the charging process does not start, the 10 A fuse in the charging cable may be
faulty. In this case, replace the fuse and check the cabling.
13. Specifications
Operating voltage................................................. 220 - 240 V/AC (50/60 Hz)
End-of-charge voltage.......................................... 7.15 V/14.3 V
Charging current................................................... max. 1000 mA
Housing protection class....................................... IP 65
Operating conditions............................................. -15°C to +45°C, 10% to 90%
relative air humidity,
non-condensing
Storage conditions................................................ -30°C to +60°C, 10% to 90%
relative air humidity, non-
condensing
Dimensions (W x H x D)....................................... approx. 145 x 54 x 42 mm
Weight................................................................... approx. 350 g
Length of power cord............................................ approx. 170 cm
Length of charging cable (total)............................ approx. 230 cm
Fuse protection for charging cable....................... 10 A
Usable battery types............................................. Lead-acid, lead-gel, lead-fleece,
(AGM), calcium, pure lead
automotive batteries
Battery voltage...................................................... 6 V or 12 V (switchable)
Battery capacity (recommended).......................... 1.2 Ah to 40 Ah
Heruntergeladen von