MAINTENANCE
Translation of the original instructions
23
5.2
Spare parts
It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on
the type of appliance) or the gas pipes easily and quickly.
To replace such parts, proceed as follows:
·
POWER REGULATOR or SWITCH: Remove the knob and open the panel, unscrew the two screws that
fasten the switch/regulator to the panel, remove all the electrical connections and proceed with
replacement
·
GENERATOR ; remove the panel and the rear spacer and disconnect all the cables. From the front,
unscrew the two screws that fasten the generator and remove it. Then remove the protective enclosure,
apply it on the new generator and proceed with replacement.
Caution
WHAT TO DO IN THE EVENT OF FAULTS:
Close the gas connection cock and/or switch off the power using the up-line device. Notify
customer service.
Warning
MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME:
Close the gas cock and/or disconnect the power supply. Clean the system as specified above.
Note
The induction generators must be opened only by authorised and qualified personnel. No
reproductions and/or modifications on the generator are permitted