INSTALLATION

Translation of the original instructions

9

 
For burners equipped with air adjustment, set the adjustable bushing and lock it with a screw. The "Burner
technical data" table shows approximate values for the "h" parameter (primary air). The primary air flow
volume must be adjusted to avoid a flame cut-off when the burner is cold and a flame blowback when the
burner is hot. The pilot air adjustment is set testing for the gas which the appliance will use. In the event of
conversion to other types of gas, adjust the air using the adjustment bush until the pilot flame is steady and
has an intense blue colour.
 
Disposition for conversion and installation for other types of gas:
 
Our appliances are tested and set for liquid gas or natural gas (see attached data plate). Conversion or
adaptation to another type of gas must be performed by a specialist technician. The nozzles for the various
types of gas are contained in a bag included in the supply and are marked in hundredths of mm (see
"Burners" technical data table).
 

·

INSTRUCTIONS FOR EVACUATING EXHAUST GASES

 
- "A" type devices (see data plate)
 
"A" type appliances must discharge combustion products into appropriate hoods, or similar devices,
connected to an efficient fume stack or directly to the outside. (Natural evacuation) Fig. 1
If this is not possible, using an air suction device connected directly to the outside is permitted (Forced
Evacuation) Fig.2, having a flow capacity not lower than the value defined in point 4.3 of the UNI-CIG 8723
standard.
 
- In the case of forced evacuation
 
The gas supply to the appliance must be directly servo-controlled by the system and must stop if the flow
rate drops below the values indicated in point 4.3 of the UNI-CIG 8723 standard. Resetting the gas supply to
the appliance must be possible only by hand.

 

1 Extractor hood
2 Servo system
 
- "B11" type devices (See data plate)
 
Natural evacuation (fig.3)
Connection to an efficient natural draft fume stack by means of a windproof connection, with discharge of
combustion products directly to the outside
 

Summary of Contents for FMPG-20

Page 1: ...n and operating instructions PROFESSIONAL GAS PASTRY FRYER FPG 20 FPG 30 FMPG 20 FMPG 30 Model LIBR ISTR FPG Code 563010300 Review 1 Edition date 05 02 2020 Language English LOTUS S p A Via Calmaor 46...

Page 2: ...ections 7 4 BURNERS TECHNICAL DATA TABLE ITGB 11 4 1 Burners technical data table 11 5 INSTRUCTIONS FOR USE 12 5 1 General information 12 5 2 Switching the pilot burner on 12 5 3 Starting the main bur...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FPG 20 30 A Data Plate C Gas connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 FMPG 20 30 A Data Plate C Gas connection...

Page 5: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 6: ...ginal instructions 6 2 2 Technical data table Technical data table FPG MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW FPG 20 60x70x25h R GM 11 2 FPG 30 80x70x25h R GM 16 5 FMPG 20 60x70x...

Page 7: ...nstall the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating m...

Page 8: ...t do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indi...

Page 9: ...ned in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must d...

Page 10: ...iance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The ou...

Page 11: ...h KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar FPG 20 FMPG 20 Burner 11 2 kW Burner injector 1 100 mm 3 x 100 3 x 100 3 x 150 Pilot injector 30 30 51 Consumption kg h 0 875 kg h 0 875 m3...

Page 12: ...witching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 5 2 Switching the p...

Page 13: ...than oil lard for example that have considerable thermal inertia it is necessary to set the thermostat to a low value e g 110 C during the first cycle not starting cold The thermostat can be set to t...

Page 14: ...uired to have a suitable recipient for emptying the water oil Insert the drain tube as shown on the drawing position the container Push the safety device upwards against the involuntary openings A and...

Page 15: ...ted on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing t...

Page 16: ...le with the appropriate version and make sure that after ignition the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas update the technical data plat...

Page 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: