Lotus FMPG-20 Installation And Operating Instructions Manual Download Page 7

INSTALLATION

Translation of the original instructions

7

3 INSTALLATION

3.1

Delivery checks

On delivery, it is important to check the following:
 

·

External conditions of the packaging

·

The general status of the equipment

·

The conformity of the model with the information in the technical data plate and the instruction manual

·

The conformity of the equipment and components to the order form

 

3.2

Removing the packaging

While removing the packaging, take care not to damage the appliance. Remove the protective film from the
stainless steel and eliminate any traces of glue. Do not smoke. Perform this operation away from sources of
heat and wear protective gloves. Do not disperse packaging material in the environment, keep it out of the
reach of children and dispose in compliance with current legislation.
 

3.3

Mechanical installation

Place the appliance on a flat base. Adjust and stabilise the appliance by acting on the support feet. Make
sure that the surrounding walls and/or equipment are capable of withstanding the heat emitted by this
appliance. Connect the water supply (if necessary).
 

Caution

 

Do not install the appliance near equipment/machines used in cold processes. If the appliance
has to be installed close to cold process equipment, it is advisable to install non-combustible
thermal insulating material and/or neutral elements between them.

 

3.4

Electrical/gas connections

Before being offered for sale on the market, the appliance was subjected to gas and electrical testing (as
required). The appliance is supplied without a power cable. The installation technician must connect the
equipment in compliance with current safety regulations on the basis of the power of the appliance.

Note

 

The ID plate is located in the compartment inside the door for appliances with compartments, or on
the left side for appliances with an oven or a top. A second plate with the model and serial number is
located inside the dashboard and a third is included with the certificate of conformity. The serial
number can also be tracked from the sales document (after 2008). The plate has all the data needed
for correct electrical installation. The installation and possible conversion to another power supply
voltage (if envisaged) must be implemented exclusively by professionally qualified and authorized
personnel. Before using the appliance, carefully clean all surfaces intended to come into contact with
food.

 

Warning

Summary of Contents for FMPG-20

Page 1: ...n and operating instructions PROFESSIONAL GAS PASTRY FRYER FPG 20 FPG 30 FMPG 20 FMPG 30 Model LIBR ISTR FPG Code 563010300 Review 1 Edition date 05 02 2020 Language English LOTUS S p A Via Calmaor 46...

Page 2: ...ections 7 4 BURNERS TECHNICAL DATA TABLE ITGB 11 4 1 Burners technical data table 11 5 INSTRUCTIONS FOR USE 12 5 1 General information 12 5 2 Switching the pilot burner on 12 5 3 Starting the main bur...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FPG 20 30 A Data Plate C Gas connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 FMPG 20 30 A Data Plate C Gas connection...

Page 5: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 6: ...ginal instructions 6 2 2 Technical data table Technical data table FPG MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW FPG 20 60x70x25h R GM 11 2 FPG 30 80x70x25h R GM 16 5 FMPG 20 60x70x...

Page 7: ...nstall the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating m...

Page 8: ...t do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indi...

Page 9: ...ned in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must d...

Page 10: ...iance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The ou...

Page 11: ...h KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar FPG 20 FMPG 20 Burner 11 2 kW Burner injector 1 100 mm 3 x 100 3 x 100 3 x 150 Pilot injector 30 30 51 Consumption kg h 0 875 kg h 0 875 m3...

Page 12: ...witching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 5 2 Switching the p...

Page 13: ...than oil lard for example that have considerable thermal inertia it is necessary to set the thermostat to a low value e g 110 C during the first cycle not starting cold The thermostat can be set to t...

Page 14: ...uired to have a suitable recipient for emptying the water oil Insert the drain tube as shown on the drawing position the container Push the safety device upwards against the involuntary openings A and...

Page 15: ...ted on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing t...

Page 16: ...le with the appropriate version and make sure that after ignition the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas update the technical data plat...

Page 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: