Lotus FMPG-20 Installation And Operating Instructions Manual Download Page 15

MAINTENANCE

Translation of the original instructions

15

6 MAINTENANCE

6.1

Routine

When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation.
We therefore recommend stipulating a service contract.
 

Caution

 

Maintenance  must  only  be  performed  by  specialist  personnel  in  compliance  with  current
regulations and our own instructions.

 

Before carrying out any maintenance and/or cleaning operation:
 

·

Disconnect the appliance from the mains power supply and/or close the gas.

·

Wait for a sufficient time for the appliance to cool down.

·

Do not wash the appliance with direct or high-pressure jets of water, since any infiltration of water into the

electrical components could jeopardise correct operation of the appliance and its safety systems.

 

Warning

 

For maintenance/replacement of components, order and use only original spare parts.

 

Replacing parts must exclusively be performed by authorised and/or qualified personnel. When replacing the
electrical components of the machine and the electrical panels, scrupulously follow the technical
characteristics for the replacement component indicated on the component itself. The appliance does not
require any special maintenance but during the use of the equipment it is advisable to check the following at
least once a year (possibly increasing the frequency depending on the degree of use):
 

·

The status of connections especially on the terminal board and the power supply cable, as well as the

status of the gas connections;

·

The operating condition of the various components (perform a functional test);

·

For appliances fitted with rotary resistances, remove the hub, grease it and replace the three o-ring seals

to avoid possible leaks.

6.2

Replacing the main burner nozzle

·

Remove the front screws fastening the dashboard/panel and pull it outwards

·

Detach the starter cable

·

Unscrew the nut and lower the air adjustment bracket

·

Using a suitable wrench, unscrew the nozzle and replace it with an appropriate new one

·

Refit the air adjustment bracket in its initial position. Pay attention since the height of the bracket depends

on the type of gas used (see technical data table)

 

6.3

Replacing the pilot burner nozzle

The pilot burner flame has a fixed air supply. The only necessary item is replacement of the nozzle
depending on the type of gas used (see technical data table).
 

·

Unscrew the coupling connecting the pilot tube to the pilot itself and slide out the nozzle to be replaced

Summary of Contents for FMPG-20

Page 1: ...n and operating instructions PROFESSIONAL GAS PASTRY FRYER FPG 20 FPG 30 FMPG 20 FMPG 30 Model LIBR ISTR FPG Code 563010300 Review 1 Edition date 05 02 2020 Language English LOTUS S p A Via Calmaor 46...

Page 2: ...ections 7 4 BURNERS TECHNICAL DATA TABLE ITGB 11 4 1 Burners technical data table 11 5 INSTRUCTIONS FOR USE 12 5 1 General information 12 5 2 Switching the pilot burner on 12 5 3 Starting the main bur...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FPG 20 30 A Data Plate C Gas connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 FMPG 20 30 A Data Plate C Gas connection...

Page 5: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 6: ...ginal instructions 6 2 2 Technical data table Technical data table FPG MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW FPG 20 60x70x25h R GM 11 2 FPG 30 80x70x25h R GM 16 5 FMPG 20 60x70x...

Page 7: ...nstall the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating m...

Page 8: ...t do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indi...

Page 9: ...ned in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must d...

Page 10: ...iance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The ou...

Page 11: ...h KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar FPG 20 FMPG 20 Burner 11 2 kW Burner injector 1 100 mm 3 x 100 3 x 100 3 x 150 Pilot injector 30 30 51 Consumption kg h 0 875 kg h 0 875 m3...

Page 12: ...witching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 5 2 Switching the p...

Page 13: ...than oil lard for example that have considerable thermal inertia it is necessary to set the thermostat to a low value e g 110 C during the first cycle not starting cold The thermostat can be set to t...

Page 14: ...uired to have a suitable recipient for emptying the water oil Insert the drain tube as shown on the drawing position the container Push the safety device upwards against the involuntary openings A and...

Page 15: ...ted on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing t...

Page 16: ...le with the appropriate version and make sure that after ignition the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas update the technical data plat...

Page 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...