![Lotus 3499 Installation Operation & Maintenance Download Page 16](http://html.mh-extra.com/html/lotus/3499/3499_installation-operation-and-maintenance_1941192016.webp)
16
IST079 12/01/04
I. INSTALLATION INSTRUCTIONS
GB + IE
1 GENERAL RECOMMENDATIONS
• The machine must be installed by qualified personnel following
the manufacturer's instructions, in compliance with the standards
in force.
• Read carefully the recommendations in this booklet and the
instructions they provide regarding the safe in-stallation, operation
and maintenance of the appliance
• Keep this booklet where it is readily accessible to the operators.
• After having removed the packing, check the condition of the
appliance. If in doubt, do not use the appliance and contact the
authorized supplier.
• All the packing materials used with the appliance are compatible
with the environmental protection standards.
• They can be stored without danger or burned in a suitable waste
incineration plant.
• Recyclable plastic components are identified as follows:
• POLYETHYLENE: external packing sheet, instructions
bag, etc.
• POLYPROPYLENE: fastening straps, etc.
• Before connecting the appliance, make sure that the data on the
rating tag correspond to those of the water and gas supply
network.
• The appliance shall only be operated by properly trained
personnel.
• Before carrying out any cleaning and maintenance, disconnect
the appliance from the gas supply.
• Failure to comply with these recommendations could compromi-
se the safety of the appliance.
The manufacturer declines any liability for damage resulting
from incorrect installation, tampering, improper use, faulty
maintenance, noncompliance with local provisions and
unskilled operation of the appliance.
1 CONFORMITY TO EEC DIRECTIVES
The appliances are produced in accordance with European Union
Directives:
• 90/396 CEE (Gas appliances)
• 89/392 CEE (Machines directive)
2 DATA PLATE
The specification plate of this appliance is found on the lower right
hand side of the front panel.
It gives all necessary technical information for installation.
TYPE OF GAS
Main burner injectors
Pilot-light injector
By-Pass
Main burner air position
Ø 1/100 mm
pilota N
Ø 1/100 mm
H mm
Natural gas G20
3 x 230R
27
Adjustable
All open without adjustment
Liquid gas G30
3 x 160
22
200
All open without adjustment
Liquid gas G31
3 x 160
22
200
All open without adjustment
TYPE OF GAS
Gas output
Supply pressure
Air for combustion
kW
mbar
m
3
/h
Nominal
Reduced
Nominal
Minimum
Maximum
Natural gas G20
Liquid gas G30
Liquid gas G31
24
24
24
9
9
9
20
28
37
15
20
25
25
35
45
96
96
96
Table 2 - Injectors
Table 3 - Gas connection
Table 1 - General characteristics
Mode
l
Code
Container capacity
to the edge
litres
usable
litres
Jacket capacity
min. level
litres
max. level
litres
Jacket design pressure
bar
Container design pressure
bar
Thermic rated power
kW
Minimum thermic power
kW
Type of contruction
GB
IE
Gas consumption
(calculated by the calorific value inf. “Hi” to 15C and 1013mbar)
Natural gas G20 (Hi=34,02 MJ/m
3
)
m
3
/h
Liquid gas G30 (Hi=45,65 MJ/kg)
kg/h
3 INSTALLATION TECHNICAL DATA
(GB - CATEGORY II2H3+)
(IE - CATEGORY II2H3+)
PE
PP
PI100-98G
PI150-98G
3518
3521
110
145
100
150
55
60
20
25
0,5
0,5
0,05
24
24
9
9
B11
B11
A
A
2,54
2,54
1,88
1,88
Summary of Contents for 3499